• Title/Summary/Keyword: Screw fracture

Search Result 332, Processing Time 0.029 seconds

Implant Removal after Percutaneous Short Segment Fixation for Thoracolumbar Burst Fracture : Does It Preserve Motion?

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Wang, Hui Sun;Lee, Sung Myung;Kim, Dong Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Objective : The purpose of this study was to evaluate the efficacy of implant removal of percutaneous short segment fixation after vertebral fracture consolidation in terms of motion preservation. Methods : Between May 2007 and January 2011, 44 patients underwent percutaneous short segment screw fixation due to a thoracolumbar burst fracture. Sixteen of these patients, who underwent implant removal 12 months after screw fixation, were enrolled in this study. Motor power was intact in all patients, despite significant vertebral height loss and canal compromise. The patients were divided into two groups by degree of osteoporosis : Group A (n=8), the non-osteoporotic group, and Group B (n=8), the osteoporotic group. Imaging and clinical findings including vertebral height loss, kyphotic angle, range of motion (ROM), and complications were analyzed. Results : Significant pain relief was achieved in both groups at final follow-up versus preoperative values. In terms of vertebral height loss, both groups showed significant improvement at 12 months after screw fixation and restored vertebral height was maintained to final follow-up in spite of some correction loss. ROM (measured using Cobb's method) in flexion and extension in Group A was $10.5^{\circ}$ ($19.5/9.0^{\circ}$) at last follow-up, and in Group B was $10.2^{\circ}$ ($18.8/8.6^{\circ}$) at last follow-up. Both groups showed marked improvement in ROM as compared with the screw fixation state, which was considered motionless. Conclusion : Removal of percutaneous implants after vertebral fracture consolidation can be an effective treatment to preserve motion regardless of osteoporosis for thoracolumbar burst fractures.

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

Biodegradable Meniscus Screw Fixation of Thin Flap Osteochondral Fracture - Two Case Report - (흡수성 반월상 연골나사를 사용한 얇은 골연골 골절의 치료 - 증례 보고 -)

  • Chon, Je-Gyun;Sun, Doo-Hoon;Song, In-Soo;Kim, Young-Woo;Jung, Jae-Yong;Lee, Bong-Ju
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.131-134
    • /
    • 2010
  • Inappropriate treatment of osteochondral fracture can cause osteoarthritis, pain, functional disorder. With large osteochondral fracture, reduction and fixation of the fragment using metal implant. However, when the bone fragment had less than 2mm, the fragment extracted because of difficulty of fragment fixation. Authors treated patients with fracture fragment thickness less than 2mm of osteochondral dissecans in medial femoral condyle and patella fracture using biodegradable meniscus screw, and then we obtained good result.

  • PDF

Bone Cement-Augmented Short Segment Fixation with Percutaneous Screws for Thoracolumbar Burst Fractures Accompanied by Severe Osteoporosis

  • Jung, Hyun Jin;Kim, Seok Won;Ju, Chang Il;Kim, Sung Hoon;Kim, Hyen Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.353-358
    • /
    • 2012
  • Objective : The purpose of this study was to determine the efficacy of bone cement-augmented short segment fixation using percutaneous screws for thoracolumbar burst fractures in a background of severe osteoporosis. Methods : Sixteen patients with a single-level thoracolumbar burst fracture (T11-L2) accompanying severe osteoporosis treated from January 2008 to November 2009 were prospectively analyzed. Surgical procedures included postural reduction for 3 days and bone cement augmented percutaneous screw fixation at the fracture level and at adjacent levels without bone fusion. Due to the possibility of implant failure, patients underwent implant removal 12 months after screw fixation. Imaging and clinical findings, including involved vertebral levels, local kyphosis, canal encroachment, and complications were analyzed. Results : Prior to surgery, mean pain score (visual analogue scale) was 8.2 and this decreased to a mean of 2.2 at 12 months after screw fixation. None of the patients complained of pain worsening during the 6 months following implant removal. The percentage of canal compromise at the fractured level improved from a mean of 41.0% to 18.4% at 12 months after surgery. Mean kyphotic angle was improved significantly from $19.8^{\circ}$ before surgery to 7.8 at 12 months after screw fixation. Canal compromise and kyphotic angle improvements were maintained at 6 months after implant removal. No significant neurological deterioration or complications occurred after screw removal in any patient. Conclusion : Bone cement augmented short segment fixation using a percutaneous system can be an alternative to the traditional open technique for the management of selected thoracolumbar burst fractures accompanied by severe osteoporosis.

Treatment of Secondary Soft Tissue Compromised Calcaneus Fractures Using a Cannulated Screw and Simple Cerclage Wiring: A Report of Two Cases (이차적인 연부조직 손상을 동반한 종골 골절에 대한 유관 나사 및 단순 환상 강선 고정술을 이용한 치료: 2예 보고)

  • Kim, Junkyom;Suh, Jae Wan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.165-169
    • /
    • 2017
  • Secondary soft tissue injuries can occur from the pressure of the displaced fragment of posterior calcaneal tuberosity in calcaneal tongue-type fractures and calcaneal tuberosity avulsion fractures. The soft tissue injury can be prevented by immediate reduction of the displaced fragments. Various techniques can be used to fix the fracture fragments, but the stability of fixation and minimal invasiveness to soft tissue should be considered. This paper reports the successful outcomes of patients with soft tissue compromises in calcaneal tongue-type fractures and calcaneal tuberosity avulsion fractures. The fixation technique of a large cannulated screw and simple cerclage wiring is believed to be a useful surgical option for the treatment of secondary soft tissue compromised calcaneal fractures.

Two Part Triplane Fracture with Extention through Medial Malleolus (Four Cases Report) (족관절 내과를 침범한 두 부분 삼면 골절(4예 보고))

  • Cha, Seung-Do;Kim, Hyung-Soo;Chung, Soo-Tae;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Kim, Yong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • The triplane fracture has been described as a fracture of the distal tibial epiphysis occurring across three planes-sagittal, transverse and coronal. The characteristic pattern of fusion of distal tibial epiphysis explains the special configuration of the fragments in the triplane fracture. According to Dias-Tachdjian classification, triplane fracture is classified two part fracture, three part fracture, four part fracture and two part fracture with extension to the medial malleolus. Among four types, two part triplane fracture with extension to the medial malleolus is a relatively rare injury and generally is not treated by closed reduction. Such fractures should have an anatomic reduction and adequate fixation to restore the joint congruity and obtain an anatomic reduction of the growth plate to prevent a future growth deformity. This is usually best accomplished with an open reduction and screw fixation or k-wire fixation. We experienced two part triplane fracture with extension to medial malleolus and check the CT to define the extent of the injury completely. And then we underwent open reduction and screw fixation for the fracture. As a result, we present four cases of two part triplane fracture with extension with review of related literatures.

  • PDF

Unusual Anterior Arch Fracture of C1 - Case Report - (Unusual Anterior Arch Fracture of C1 - 증 례 보 고 -)

  • Kim, Sang Jin;Son, Chan Young;Kim, Tae Hong;Shin, Hyung Sik;Hwang, Young Soon;Park, Sang Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.537-540
    • /
    • 2001
  • Fractures of C1 are not uncommon, constituting only 10% of all cervical spine injuries. There is a high prevalence of concomitant fractures of the second and first cervical vertebral complex. Surgical treatment is controversal. Mainstay of treatment is various combination of traction and cervical orthosis according to degree of displacement and location of fracture. We experienced unusual type of fracture, anterior arch fracture of C1 who had a history of total laminectomy of C1,2 due to cervical cord tumor(neurilemmoma arising from C2 root). We performed C1,2 lateral mass screw fixation with posterior fusion with good postoperative outcome.

  • PDF

Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric Fractures: A Case Series

  • Rai, Avinash Kumar;Goel, Rajesh;Bhatia, Chirag;Singh, Sumer;Thalanki, Srikiran;Gondane, Ashwin
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients. Materials and Methods: In this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system. Results: More patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be $-2.506{\pm}0.22$ (mean${\pm}$standard deviation); all patients were within the range of -2.0 to -2.8. The duration of radiological union was $13.67{\pm}1.77$ weeks. Salvati and Wilson's scoring at 12 months of follow up was $30.96{\pm}4.97$. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out. Conclusion: Bone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.

Effective Reduction of the Frontal Process of the Maxillary Fracture Segment Using Intermaxillary Fixation Screw (악간고정용 스크류를 이용한 위턱뼈 이마돌기 골절편의 효과적인 정복)

  • Moon, Suk-Ho;Lee, Woo-Sung;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae;Oh, Deuk-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.555-558
    • /
    • 2011
  • Purpose: It is relatively unusual that infraorbital rim fracture is accompanied by nasal bone fracture. In order to correct effectively, subciliary approach and intranasal manipulation are applied simultaneously. But if reduction is not successful, intranasal manipulation may become aggressive and this often causes complications. We introduce a method using intermaxillary fixation screws for decreasing such complications and effective reduction of fracture. Methods: Total seven patients with fracture of frontal process of maxilla were treated with this method. The fracture site was exposed through the subciliary approach, and one or two screws were inserted into the displaced fracture fragment. During the traction of the screws using the wire, the fracture fragment was pushed upward from the intranasal side using an elevator supplementarily and fixed with a plate and the screws. Results: In all patients, the fracture fragment was reduced successfully and no complication occurred during one year's postoperative follow-up. Conclusion: When reduction cannot be attained through a bone hook or an elevator alone, reduction of fracture fragment can be done easily using intermaxillary fixation screws. This method is less likely to cause a mucosal injury because intranasal manipulation is not aggressive. Furthermore, as the screw can be inserted and removed easily, this method is considered effective not only for fracture of frontal process of maxilla but also for fractures in other regions.

The Development of Pin Screws into the Bone for External Fixator (체외 고정구용 골 삽입 금속 나사 개발)

  • Choi, Y.C.;Rhee, K.M.;Na, W.H.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.5-17
    • /
    • 2009
  • We developed bone-insertion pin screw that can be used for purposed treatment by combining with the external fixator which is the subsidiary tool for the healing of the fracture (open fracture of long bone, reconstruction of soft tissue and arthrodesis etc.) Furthermore, for the frist time, we succeeded in domestic-producing this screw, using specially-designed treating tool stuck on the lathe machine and abrasive blasting machine, and the post-dealing technique and process. In comparison with other foreign products, we could get more desirable results in various tests. This pin screw has 103% characteristics of the average of foreign products. Thus we'd like to introduce design techniques, post-dealing process and result of function tests.

  • PDF