• 제목/요약/키워드: Screw driver

검색결과 31건 처리시간 0.024초

로봇 요소품 설계 프로그램 개발 (Development of a Robot Element Design Program)

  • 정일호;김창수;서종휘;박태원;김희진;최재락;변경석
    • 한국정밀공학회지
    • /
    • 제22권4호
    • /
    • pp.113-120
    • /
    • 2005
  • This paper presents the development of the design of the robot element. Robot element design is an important part of robot design since it decides the performance and life time of the robot. It is necessary that the robot kinematics and the robot dynamics are accomplished to design the robot elements. The robot kinematics and dynamics determine the design parameters of the element. We developed a robot element design program with which a designer can design the robot element with convenience and reliability. The program is composed of motor, harmonic driver and ball-screw design. The program is founded on the virtual robot design program. The virtual robot design program is the powerful software which may be used to solve various problems of the robot kinematics and dynamics. The robot element design program may be used to calculate the design parameters of the element that are necessary to design robot element. Therefore, the designer can decide upon the available robot elements available to perform the objective of the robot. The robot element design program is expected to increase the competitiveness and efficiency of the robot industry.

Comparison of the torque stability of Implant Torque Controllers

  • Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Korean Dental Science
    • /
    • 제2권1호
    • /
    • pp.19-27
    • /
    • 2009
  • Tightening of the screws in implant restorations should be accurate and precise. If applied torque is too low, screw loosening would be occurred. With too high torque, the screw fracture might take place. Various torque generating devices are developed and employed to apply a proper torque. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; electronic torque controller, torque limiting device, torque indicating device and contra angle torque driver. Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were done with each torque controller. All implant torque controllers have shown slight errors and deviations. The torque liming device exhibited the most accurate data. No significant difference was found among the mean de-torque values of the electronic torque controller, torque indicating device and contra angle torque driver. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

  • PDF

감속 스텝모터를 이용한 2축 인장·전단 시험기의 개발 (Development of Biaxial Tension & Shear Tester using Stepper Motor with Harmonic Driver)

  • 최병선;배원호;채영석
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.379-386
    • /
    • 2001
  • The lower toughness or brittle materials for mechanical test lead to the additional requirement that applied displacements be controlled with high resolution. Biaxial tension and shear tester using stepper motor with harmonic driver is shown. The device had to be high resolution so that the crack initiation process of slow extension and steady growth could be examined, Grip plates were connected to a linear bearing and actuator. The actuators consisted of stepper motors with harmonic driver connected to pre-loaded ball screw and nut assemblies. The encoders and motor controllers were connected to a personal computer so that arbitrary displacements histories could he prescribed in normal and tangential directions. The linear bearings were used to react loads perpendicular to their axes while allowing low friction, parallel movement of the attached grips. Load cells measured the reactions normal and tangential. the loads measured the reactions were recorded by the computer.

  • PDF

관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 - (Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report -)

  • 김형식;고일현;김성국;천용민;김성재;강호정
    • Clinics in Shoulder and Elbow
    • /
    • 제14권1호
    • /
    • pp.94-98
    • /
    • 2011
  • 목적: 견갑골 전방 관절와 분쇄 골절에 대해 관절경하 정복 및 AO 무두 압박 나사를 이용하여 골편을 고정한 증례를 보고하고자 한다. 대상 및 방법: 31세 남자로 내원 2주 전 추락 후 발생한 좌측 견관절의 전방 관절와 분쇄 골절에 대하여 관절경하에서 골절을 정복한 후, 표준 전상방 삽입구를 통해 1.1 mm K 강선을 가이드핀으로 삽입하고 AO 무두 압박 나사로 골편을 고정하였다. 결과: 수술 후 12개월째 견관절의 운동 범위는 정상 범위로 회복 되었으며, 골절은 유합을 얻었고 일상 생활에 불편감은 없었다. 결론: AO 무두 압박 나사는 나사의 길이가 다양하여 작은 관절와 골편에 사용하기 적합하고, 가이드 핀의 길이가 상대적으로 짧으나 1.1 mm K 강선으로 대체가 가능하며, 나사 돌리개 (screw driver)나 천공기 (drill bit) 등의 동반 기구의 길이가 길어 비교적 깊은 위치의 견갑과 골절의 고정에 사용하기 편리하여 관절경적 고정술 시 유용하게 이용할 수 있을 것으로 생각된다.

임플란트 고정체와 지대주의 체결방식에 따른 스크류 풀림토크에 관한연구 (A Study on the Screw Loosening Torque According to the Type of Tightening the Implant Fixture and Abutment)

  • 박수철;김홍식;함성원
    • 대한치과기공학회지
    • /
    • 제35권3호
    • /
    • pp.201-207
    • /
    • 2013
  • Purpose: In this study, the loosening torque test was conducted with three implant products that are produced, approved and sold in Korea, which are manufactured in different fixture and abutment tightening methods (internal submerged type, internal morse taper type, and external type) to examine the loosening torque of the screw according to the method of tightening the implant fixture and abutment. Methods: In the loosening torque test, the three types of fixtures and abutments with different tightening methods were tightened by rotating them clockwise with a $30N{\cdot}cm$ force using a driver equipped with an electric torque meter. The results of the test are as follows. Results: The loosening torque values of the internal submerged type, internal morse taper type and external type implants were $24.10{\pm}0.742N{\cdot}cm$, $29.10{\pm}1.710N{\cdot}cm$, and $26.60{\times}1.636N{\cdot}cm$, respectively. Conclusion: The screw loosening torque values of the three fixture and abutment tightening methods were analyzed via Kruskal Wallis test layout, and they were significantly different (p<0.05).

콤비네이션 임프란트 크라운(Combination Implant Crown)을 이용한 단일치아의 임프란트 보철수복증례 (SINGLE TOOTH IMPLANT RESTORATION USING COMBINATION IMPLANT CROWN : A CASE REPORT)

  • 김래경;송언희;최병갑;김현철;안현정
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.375-382
    • /
    • 1999
  • The purpose of this article is to present the clinical and laboratory procedures for single tooth restoration using 'Combination Implant Crown'. It is cemented on implant abutment and that abutment is screw-retained over implant body. This type of implant restorations has the advantages of cement-retained restoration while being antirotational and retrievable. And, more esthetic and functional result can be achieved by minimizing the size of access hole. The results were as follows : 1. Preparation of abutment below the cuff line should be avoided 2. Axial reduction of implant abutment should not be excessive because it may weaken the abutment 3. More esthetical and functional occlusal surface was achieved with a minimal access hole which is slightly larger than the diameter of hex driver to enable future total retrievability. 4. Combination Implant Crown has the advantages of both the cement-retained and screw-retained type implant restoration. 5. Cementation between implant crown and abutment reduces screw loosening through even force distribution

  • PDF

수종 임플랜트 시스템에서의 회전력에 관한 연구 (A STUDY ON THE TORQUE VALUES IN THE DIFFERENT IMPLANT SYSTEM)

  • 문익훈;정재헌
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.335-353
    • /
    • 1995
  • The purpose of this study was to the determine the optimal torques values to tighten the retaining screw. 3-different implant system tested were as follows : Branemark implant system$(3.75mmD{\times}100mm)$, Steri-Oss implant system$(3.8mmD{\times}10mm)$. One fixtures of each implant system was mounted into the epoxy resin block and abutment/superstructure complex was constructed. Eighty dental college students(male : 40, female : 40) of Chosun University were selected and were asked to tighten the retaining screws. Abutment/superstructure complex of each implant system was tightened to the maximum torque by use of hand-held screw driver, and then torque value was measured with torque value was measured with torque driver(Tohnichi torque driver, model 20 FTD, Tohnichi MFG, Co., LTD., Tokyo, Japan). Abutment/superstructure complex of each implant system was titghtened to each torque of 10 N-cm, 20 N-cm and 30 N-cm, and then the dynamic load(vertical & diagonal load) was applied to the abutment / superstructure complex. The gap between abutment/superstrure in each implant system was measured with 3-dimensional measuring microscope(model No. 850, Germany). The results were as follow : 1. Torque values according to the individual subjects showed wide range. 2. Torque values according to sex showed statistical significant difference. Those are as follows : in case of male, $9.38{\pm}2.93$ N-cm ; incase of female, $7.80{\pm}2.25$ N-cm. 3. Torque values according t implant systems showed statistical significant difference. Those are as follows : in ase of Branemark implant system, $6.54{\pm}1.54$ N-cm : in ase of Steri-Oss implant system, $10.1{\pm}2.88$ N-cm ; in case of IMZ implant system, $9.18{\pm}2.17$ N-cm. 4. The more torque value of tightening screw was increased, the less the gap was after the vertical and diagonal loading. 5. The gap after the diagonal loading was greater than that after the vertical loading. 6. The magnitude of gap between abutment/superstructure in order of IMZ, Steri-Oss, Branemark implant system after the verical and diagonal loading. 7. The gap under the diagonal loading after applying 30 N-cm torque showed no statistical significant difference in cases of the Branemark system and the Steri-Oss implant system but it showed significant different in case of the IMZ implant system.

  • PDF

직접 구동방식의 터보 압축기를 위한 초고속 전동기 구동 시스템 개발 (The Development of a super high speed motor driving system for the direct drive type turbo compressor)

  • 권정혁;변지섭;최중경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.219-222
    • /
    • 2002
  • There are screw, reciprocating type turbo compressor by structure in an air compressor which is essential equipment on the industrial spot. Recently, the application range of a turbo compressor tend to be wide gradually. And this type of compressor needs high speed rotation of impeller in structure so high ratio gearbox and conventional induction motor driving required. This mechanical system have results of increased moment of inertia and mechanical friction loss. Recent studies of modern turbo compressor have been applied to developing super high speed BLDC motor and driver which remove gearbox that make its size small and mechanical friction loss minimum. To accomodate this tendency, we tried to develope a super high speed motor drive system for 150Hp, 70,000rpm direct drive Turbo compressor using DSP(Digital Signal Processor) and SVPWM(Space Vector Modulation PWM) technique. The results of this specific application show that super high speed driver and controller could be implemented well with digital electronics.

  • PDF

선천 매독성 치아기형 1예 보고 (A Case Report of Dental Defects in Congenital Syphilis)

  • 김종열;정순민
    • Journal of Oral Medicine and Pain
    • /
    • 제7권1호
    • /
    • pp.41-46
    • /
    • 1982
  • The patient, 11 yeats old male was examined for routine oral health care. He had been hospitalized for treatment of nephritis. Hos physical condition os mental retarded & undergrowth state. In oral examination, notch on cutting edge and screw-driver shaped crown of maxillary central incisors, narrow crown and dwarfed & pinched occlusal surface of lower first molars and scars(rhagades) on the angle of the lip were shown. We diagnosed the above symptoms as dental defects of congenital syphilis; Huchinson's inscisors and mulberry molar.

  • PDF

수종의 임플란트 토크 조절기의 정확성 비교 (Comparison of Accuracy of Implant Torque Controllers)

  • 김대곤;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.157-168
    • /
    • 2008
  • 네 종류의 토크 조절기(전자 토크 조절기($Br{\aa}nemark$), 토크 최대값 제한 장치(Pentaborn), 토크 표시 장치(ITI), 콘트라앵글 토크장치(Anthogyr))를 이용하여 나사의 조임 및 풀림 토크값을 측정하여 적정 토크 값과 토크 조절기를 통해 적용되는 실제 토크값에 대한 차를을 측정하여 토크 조절기의 정확도를 비교, 분석하였다. 풀림토크의 평균값 및 최대값과 최소값을 살펴 본 결과 Pentaborn과 같은 토크 최대값 제한 장치의 정확도가 다른 세 종류의 토크 조절기에 비해 우수한 것으로 나타났으며 15회 정도의 조임과 풀림은 큰 영향을 미치지 않지만 그 이상의 조임과 풀림은 정확한 토크 조절에 나쁜 영향을 미치는 것을 알 수 있었다. 그러므로 토크 조절기가 일정하고 정확한 토크값을 반복적으로 유지하는지 확인 및 교정하면서 임상적으로 적용해야 할 것으로 사료된다.