• Title/Summary/Keyword: Screw driver

Search Result 31, Processing Time 0.026 seconds

THE EFFECTS OF THE DESIGN OF ABUTMENT SCREW DRIVER ON THE AMOUNT OF TIME FOR INSERTION OF SCREW DRIVER INTO ABUTMENT SCREW HEAD (임플랜트 지대주 나사와 드라이버의 설계가 보철물 장착 및 철거 시간에 미치는 영향에 관한 연구)

  • Kim Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.258-263
    • /
    • 2005
  • Statement of problem. Implant screw loosening has been remained a problem in implant prosthodontics. The time needed to insert screw driver into abutment screw head should be shortened for the purpose of decreasing the chair time. Purpose. The purpose of this study was to investigate the effects of the design of abutment screw driver on the amount of time for insertion of screw driver into abutment screw head. Material and methods. Hexagonal and rectangular types of abutment screw drivers were used. The original abutment screw drivers were modified by grinding acute angle of the screw driver tip (modified drivers). Group 1 : hexagonal type abutment screw and original driver Group 2 : hexagonal type abutment screw and modified driver Group 3 : rectangular type abutment screw and original driver Group 4 : rectangular type abutment screw and modified driver UCLA lab analogues were located in acrylic resin block. The angulations of them were 0 and 20 degrees. The times needed for insertion were measured. Group 1 and 3 were used as controls. Results. 1. Group 2 showed shorter insertion time than group 1, regardless of implant angulations (p<.05). 2. Group 4 showed shorter insertion time than group 3, regardless of implant angulations (p<.05). Conclusion. Modified abutment screw drivers required less amount of time to insert screw driver into abutment screw head. Modification of abutment screw driver was beneficial.

Precision Screw Driver utilizing a Bellows (벨로우즈방식의 정 밀 나사 체결기)

  • 정규원;오의진
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.5
    • /
    • pp.53-59
    • /
    • 2001
  • A screw driver is widely used in assembling machine parts or electronic products such as the printed circuit board with a housing. As the parts to be assembled becomes small and precise, the higher precision of the controlling screw driver torque is required. However, because the operator controls the fastening torque based on experience, it must be inexact and the setting procedure will be time consuming job. Thus the screw driver which can exactly control the fastening torque is developed utilizing a bellows in this paper. The bellows is expanded by the inner air pressure and contracted by the spring operation. The bellows type driver is composed of a clutch mechanism with two solenoid valves and a pressure sensor. Those valves are controlled using the detected bellows pressure by the sensor. When the pressure reaches the setting value, the exit solenoid valve is opened to release the air pressure from the bellows so as not to deliver further torque. Through a series of experiments, the performance is examined and verified.

  • PDF

Fastening Torque Control Mechanism for Automatic Screw Driver (자동 나사 체결기의 체결력 제어 방법)

  • 오의진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.561-566
    • /
    • 2000
  • A screw driver is essentially used in assembling machine parts and electronic products such as the printed circuit board with a housing. As the parts to be assembled becomes small and precise, the higher precision of the controling screw driver torque is required. However, because the operator controls the fastening torque by his experience, it must be inexact. Thus the screw driver which can exactly control the fastening torque by a bellows is designed and developed in the study. The bellows is expanded by the inner air pressure and contracted and by the spring operation. The bellows driver is composed of the entrance solenoid valve, the exit solenoid valve and the pressure sensor. The pressure sensor senses the bellows pressure. When the pressure sensor output reaches the setting value, it operates the exit solenoid valve not to deliver further torque by letting the air of the bellows out. Through a series of experiments, the performance is studied and verified.

  • PDF

Comparison of success rates of orthodontic mini-screws by the insertion method

  • Kim, Jung Suk;Choi, Seong Hwan;Cha, Sang Kwon;Kim, Jang Han;Lee, Hwa Jin;Yeom, Sang Seon;Hwang, Chung Ju
    • The korean journal of orthodontics
    • /
    • v.42 no.5
    • /
    • pp.242-248
    • /
    • 2012
  • Objective: The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. Methods: We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. Results: The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mmlong mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Conclusions: Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.

A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.

Ergonomic Analysis of Screw Driver Workstation (스크류 드라이버 작업장의 인간공학적 분석에 관한 연구)

  • 박희석;국정훈
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.165-172
    • /
    • 1995
  • Twenty six subject drove screws with a screw driver into thick wooden sheet at three vertical and horizontal locations. Subjects drive screws for 3 minutes at each location and they assessed the conditon using the psychophysical scale. An ANOVA showed that only vertical location was a signicant factor in determining the pain ratings of various body parts. Driving screws at elbow height on the vertical surface ans with the lower arm close to the body on the horizontal surface were the work locations with the smallest ratings of perceived pain and discomfort. Wearing gloves had significant effects on reducing the pain of the hand.

  • PDF

Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System (TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석)

  • Kang, Kwan-Su;Jung, Tae-Gon;Yang, Jae-Woong;Woo, Su-Heon;Park, Tea-Hyun;Jeong, Yong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.3
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.

CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.

Ergonomic evaluation of screw driver-using workstations: Psychophysical approach (스크류 드라이버를 사용하는 작업장의 인간공학적 평가:심리육체적 접근방법)

  • 박희석
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.51-62
    • /
    • 1996
  • This research utilized the psychophysical methodology, where secrw drivers are used, to determine the effects of i) the location and orientation of work objects, and ii) wearing gloves, on ratings of perceived exertion at various body parts. The validity of the psychophysical methodology in determining a preferred work pace was also studied. The subjects drove screws with a screw driver into thick wooden sheet at three vertical and three horizontal locations. They drove serews for 3 minutes at each location and assessed the condition using the psychophysical scale. The results showed that only the vertical location was a significant factor in determining the discomfort ratings. Driving screws at elbow height on the vertical surface and with the lower arm close to the body on the horizontal surface were the work locations with the smallest ratings of perceived discomfort. Wearing gloves had significant effects on reducing the pain of the hand. From the experiment in which a comfortable work pace was identified using 20 minute psychophysical adjustment, it was found that the psychophysical method is sensitive to workers perception of the physical stress when the upper limbs are employed. This was confirmend by the high correlation between the psychophysical results and EMG measurement.

  • PDF

Development of a New Robot Manipulator Driven by the Closed-chain Actuator (폐체인 구조의 새로운 다관절 로봇 매니퓰레이터 개발)

  • 최형식;백창열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.238-245
    • /
    • 2003
  • To overcome the weakness in the load capacity of conventional robot manipulators actuated by motors with the speed reducer such as the harmonic driver, we proposed a new closed-chain type of the robot actuator which is composed of the four-bar-link mechanism driven by the ball screw. The robot manipulator is revolute-jointed and composed of four axes. The base axis is actuated by the lineal actuator such as the ball screw, and the others are actuated by the proposed actuator. We analyzed the mechanism of the actuators of the robot joints, and developed the dynamics model. The dynamics are expressed in the joint coordinates and then they are mapped into the sliding coordinates of the ball screw. We performed fundamental tests on the structure of the robot.