• Title/Summary/Keyword: Screen mode

Search Result 130, Processing Time 0.025 seconds

PSD Door Response Time Improving Method in Train Manual Operation Mode (수동운전방식에서의 PSD 출입문 신호반응 시간 개선 방안 연구)

  • Lee, Moo-Ho;Kim, Chan-Cum;Lee, Suk-Jong;Lee, Soo-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.559-571
    • /
    • 2008
  • Platform Screen Door(PSD) has been installed and operated at seoul subway line $1\sim4$ in the manual train operation mode(ATS/ATC) by SeoulMetro since 2005. SeoulMetro uses the wireless (RF) communication system and the train door detection system for the link between the train and PSD doors opening/closing motion in the manual train operation mode. For the convenience and safety of passengers, the train doors and the PSD doors opening/closing shall be synchronized as much as possible. In ATO(Automatic Train Operation) mode which provides the interface between train control system and PSD system, ATO signaling system makes the train doors and PSD doors open/close command signals systematically, so PSD doors can be opened/closed almost simultaneously with the train doors. But, in the manual train control(ATS/ATC) mode, PSD system needs to detect the train doors open/close operation and make PSD open/close command signals to actuate PSD doors. These PSD open/close commanding process cause time delay of PSD doors opening/closing motion in response to the train doors opening/closing motion. Sometimes the response delay time can be over 1 second, which is not proper to operate PSD, and need to be reduced This paper presents the reduction method of the PSD response delay time to improve the convenience and safety of passengers.

  • PDF

A Rough Mode Decision Algorithm for Transform Skip Mode in HEVC (HEVC의 Transform Skip Mode를 위한 Rough Mode Decision 알고리즘)

  • Kim, Youngjo;Kim, Jaeseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.104-113
    • /
    • 2014
  • The existing rough mode decision (RMD) algorithm, used in HEVC standard loses the coding efficiency and wastes encoding time when encoding using transform skip mode (TSM) because the RMD algorithm in HEVC uses a selection method that is designed for DCT, not for TSM. This paper proposes a new RMD algorithm for TSM in HEVC. Our proposed RMD algorithm enhances the coding efficiency by employing a new cost function to increase the probability of selecting the best intra prediction mode for TSM. In addition, it reduces the encoding time by skipping the encoding process of least feasible TSM based on a newly proposed threshold value. The experiment results show that the proposed method achieves coding gains of -0.3% for screen contents with a 10% reduction in encoding time compared to those of the HEVC standard.

Reconstitution of Digital Multiplanar Images based on Cinerama System (시네라마 시스템 기반의 디지털 다면영상의 재구성)

  • Moon, Dae-Hyuk
    • Journal of Digital Contents Society
    • /
    • v.14 no.4
    • /
    • pp.439-445
    • /
    • 2013
  • The development of digital image technology has realized high definition throughout the image industry including film and broadcasting. Such high definition images are used in various media and forms through convergence with innovative displays. The analog image production mode is combined with image content production using digital technology. The purpose of this research is to present a method to reconstitute high definition multiplanar images on the wider and bigger screen by applying the Cinerama system, one of the analog image systems in the past, to digital technology.

Development of High Reliability Monitoring and Control System for Platform Screen Door (승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발)

  • Kim, Jin-Sik;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.

A Fully-Differential Correlated Doubling Sampling Readout Circuit for Mutual-capacitance Touch Screens

  • Kwon, Kihyun;Kim, Sung-Woo;Bien, Franklin;Kim, Jae Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.349-355
    • /
    • 2015
  • A fully-differential touch-screen sensing architecture is presented to improve noise immunity and also support most multi-touch events minimizing the number of amplifiers and their silicon area. A correlated double sampling function is incorporated to reduce DC offset and low-frequency noises, and a stabilizer circuit is also embedded to minimize inherent transient fluctuations. A prototype of the proposed readout circuit was fabricated in a $0.18{\mu}m$ CMOS process and its differential operation in response to various touch events was experimentally verified. With a 3.3 V supply, the current dissipation was 3.4 mA at normal operation and $140{\mu}A$ in standby mode.

Development of a dual-mode energy-resolved neutron imaging detector: High spatial resolution and large field of view

  • Wenqin Yang;Jianrong Zhou;Jianqing Yang;Xingfen Jiang;Jinhao Tan;Lin Zhu;Xiaojuan Zhou;Yuanguang Xia;Li Yu;Xiuku Wang;Haiyun Teng;Jiajie Li;Yongxiang Qiu;Peixun Shen;Songlin Wang;Yadong Wei;Yushou Song;Jian Zhuang;Yubin Zhao;Junrong Zhang;Zhijia Sun;Yuanbo Chen
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2799-2805
    • /
    • 2024
  • Energy-resolved neutron imaging is an effective way to investigate the internal structure and residual stress of materials. Different sample sizes have varying requirements for the detector's imaging field of view (FOV) and spatial resolution. Therefore, a dual-mode energy-resolved neutron imaging detector was developed, which mainly consisted of a neutron scintillator screen, a mirror, imaging lenses, and a time-stamping optical fast camera. This detector could operate in a large FOV mode or a high spatial resolution mode. To evaluate the performance of the detector, the neutron wavelength spectra and the multiple spatial resolution tests were conducted at CSNS. The results demonstrated that the detector accurately measured the neutron wavelength spectra selected by a bandwidth chopper. The best spatial resolution was about 20 ㎛ in high spatial resolution mode after event reconstruction, and a FOV of 45.0 mm × 45.0 mm was obtained in large FOV mode. The feasibility was validated to change the spatial resolution and FOV by replacing the scintillator screen and adjusting the lens magnification.

A Standby Mode Transition Scheme for Set-top Box Power Saving by the Use Information of External Device (외부 입력기기 사용 정보 기반 셋톱박스 대기모드 전환 기술)

  • Kim, Yong-Ho;Choi, Yun-Bum;Oh, Nam-Cul;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.4
    • /
    • pp.124-130
    • /
    • 2010
  • This paper considers a power saving technique of set-top box (STB) that turns the signal into content which is then displayed on the television (TV) screen. A traditional power saving scheme, Auto Power Down (APD), was devised to reduce the power consumption of STB. APD checks whether the user is watching TV over a period of time and enforces STB into stand-by mode when the check result reveals the user is not watching TV. This paper proposes an enhanced power saving scheme that transits STB operation mode to 'stand-by' immediately when STB recognizes the change of TV's external input signal. The proposed scheme does not require the monitoring time to check the users' watching TV, and transits to standby mode faster than the conventional APD, which results in better performance in power saving. The simulation result shows that the proposed scheme achieves 2 to 11% improvement in power consumption compared with the conventional APD.

  • PDF

Biaxial Integrated Optical Film for VA Mode LCD's Made from In-situ Photopolymerised Reactive Mesogens

  • Kim, Kyeong-Hyeon;Lyu, Jae-Jin;Chung, Dong-Hoon;Verrall, M;Slaney, K;Perrett, T;Parri, O;Lee, Seung-Eun;Lee, Hee-Kyu
    • Journal of Information Display
    • /
    • v.5 no.2
    • /
    • pp.23-26
    • /
    • 2004
  • For high end, large area displays, all current LC modes require some degree of optical compensation to improve the front of screen viewing experience. Currently most optical films are laminated to the outside of the LCD cell, between the glass and polariser. In this paper we wish to show how it is possible to integrate the compensating optical film within a VA mode LCD cell. The paper will describe the process of making the biaxial film through the process of in-situ photopolymerisation of an aligned film of reactive mesogens in the cholesteric phase using polarised UV light. The film can be made on the colour filter array side of the LCD panel. In addition the process of fabricating a VA mode LCD containing this film will be described and the performance of this module will be presented.

Performance Improvement of Chroma Intra Prediction (색차채널의 화면 내 예측 성능향상 기술)

  • Park, Jeeyoon;Jeon, Byeungwoo
    • Journal of Broadcast Engineering
    • /
    • v.25 no.3
    • /
    • pp.353-361
    • /
    • 2020
  • VVC (Versatile Video Coding) is a new video compression technique that is being standardized, and it supports HD / UHD / 8K video, and High Dynamic Range (HDR) video with a goal of approximately 2 times higher coding efficiency than the conventional HEVC. It also aims to support a variety of functionalities such as screen content coding, adaptive resolution changes, and independent sub-pictures. In this paper, we investigate the signaling process of intra prediction mode first, and develop an effective coding method of the chroma intra prediction mode. In case of the DM mode, the proposed method simplifies the prediction mode of the chorma intra prediction mode when referring to the angular mode of the luminance block. It can improve coding efficiency of the chroma intra prediction mode, and the proposed process can also consider the size of the block in order to further improve its coding efficiency.

A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station (화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석)

  • Shin, Kyu-Ho;Hur, Nahm-Keon;Won, Chan-Shik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF