• 제목/요약/키워드: Screen mode

검색결과 130건 처리시간 0.026초

ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석 (A Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen)

  • 김창원;이영신;김흥태;김지원
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the safety of the driving gear reducer of ESW(essential service water) traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in operating basis earthquake(OBE) and safe shutdown earthquake(SSE), which were applied as design condition using floor response spectrum( FRS). The maximum strain of gear reducer under OBE and SSE were 20.4 ${\mu}$ and 33.6 ${\mu}$, respectively. The maximum stresses were 2.42 MPa under OBE condition and 4.36 MPa under SSE condition, which were smaller than the allowable strength of material.

ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석 (Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen)

  • 김창원;이영신;김흥태;김지원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.731-736
    • /
    • 2011
  • In this study, the safety of the driving gear reducer of ESW traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE), which was applied as design condition using Floor Respnse Spectrum(FRS). The maxsimum displacement of gear reducer under OBE and SSE were 0.0137 mm and 0.0241 mm, respectively. The maximum stress of gear reducer under OBE and SSE were 2.42 MPa and 4.36 MPa, respectively.

  • PDF

화면분할 장면에 나타나는 몽타주 특성에 관한 연구 - 미국드라마 '24' 중심으로 - (A Study on the Characteristics of Montage shown in the Spilt Screen - With Focus on Drama '24'-)

  • 강윤혁
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.698-702
    • /
    • 2007
  • 최근 영화 및 드라마, CF 등 각종 영상물에서는 하나의 화면이 서로 다른 영상들로 분할되어 구성된 장면들을 흔히 접할 수 있다. 2001년 미국에서 제작되어 2008년 시즌7 방영을 앞두고 있는 드라마 '24'에는 이런 화면분할 장면이 빈번히 등장하고 있다. '24'는 하루 동안에 발생한 일들을 한 시간짜리 24개 에피소드로 나눠 리얼타임 형식으로 보여주는 드라마로써 화면분할 장면을 통해 여러 곳에서 동시에 벌어지고 있는 사건들을 효과적으로 전달하고 있다. 특히 감각적으로 분할된 프레임들은 서로 충돌과 어울림 등의 관계를 맺으며 시청자들의 시선을 사로잡는다. 본 논문은 드라마 '24'에 등장하는 화면분할 장면을 구성하는 프레임들 간의 상호관계를 화면구성 원리를 통하여 분석하여, 시청자들의 시선을 사로잡는 원인을 영화 몽타주 이론을 통하여 살펴보고자 한다.

  • PDF

세포배양 생화학적 기법에 의한 수환경오염 평가 (Cell Culture Microbioassay for the Water Pollution Monitoring)

  • 오승민;정규혁
    • Toxicological Research
    • /
    • 제16권4호
    • /
    • pp.285-291
    • /
    • 2000
  • So far, investigation of environmental pollution has been achieved in field study. This remains the most exhaustive approach, current dimensions of environmental researches and their inherent complexity require that relatively inexpensive and simple laboratory procedures are developed to make possible the screening of large numbers of sites and samples. At this point. microbioassay has been high-lighted. The purpose of this study is to evaluate the water pollution using microbioassay. Two microbioassay methods were optimized and validated for the sensitive and quantitative determination of total toxic effects in the water. EROD(Ethoxyresorufin-O-deethylase) microbioassay was focused to detect PARs, PCBs and dioxinlike components in the water and E-screen assay to xenoestrogens. The EROD microbioassay was executed in rat hepatoma cell line, H4IIE and E-screen assay in MCF7-BUS cell line. Kumho river was selected for this study. 5ι of river water was extracted using combined solid-phase extraction in static adsorption mode with soxhlet extraction. Pollutants adsorbed to the XAD-4 resin were recovered by elution with ethyl acetate and methylene chloride (1 : 9). Toxic effects of extracts were determined by EROD-microbioassay and E-screen assay. EROD activities of water samples were 7.24-72.24 ng/ι MEQ. The estrogenic effect of various water samples is quantitatively evaluated by EEQ. The EEQ of samples range from 0.05 to 6.07 ng-EEQ/ι. These results suggested that Kumho river was highly polluted with organic toxic chemicals.

  • PDF

포아송 프로세스 모델링을 통한 셋톱박스 에너지 절감 성능 분석 (Performance Evaluation of Set-top Box Energy Saving using Poisson Process Modeling)

  • 김용호;김훈
    • 정보통신설비학회논문지
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 2011
  • This paper considers a performance analysis of set-top box (STB) power saving schemes. STB converts the signal into content which is then displayed on the television (TV) screen, and there are typically two operation modes: on mode and stand-by mode. The total energy consumption (TEC), a typical measure of power consumption of STB, is defined by the sum of power consumption in each mode. Recently there are some works of STB power saving schemes that transit STB operation modes efficiently, and the mode transition time point of those schemes can be different. Thus it is required to develop a performance evaluation method that reflects mode transition time points of each scheme to get TEC correctly. This paper proposes a performance evaluation method for STB power consumption using Poisson process to consider the mode transition time point. By modeling STB mode transitions as events of Poisson process, the average time duration of STB mode is computed and accordingly the effect of power saving is evaluated. The performance evaluation result shows that the proposed method achieves 1 to 19% improvement in power consumption compared with a conventional performance evaluation method.

  • PDF

서울메트로 PSD 통합관제시스템 구축방안에 대한 연구 (Study on Implementation Scheme for Integrated PSD Control System of Seoul Metro)

  • 김용협;현용섭;류호중;김진수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1551-1559
    • /
    • 2007
  • Seoul Metro has been constructing the screen doors on the platforms to provide safe and comfort environments. The screen doors of each station are configured so that they can be operated in automatic mode in connection with ATC/ATO through the integrated control panel in the station control room and in manual mode through the control panel of the station control room and crew control panel. These systems have been implemented with different data communication protocols between systems, HMI configuration, and so on due to ordering processes, implementation time and diverse suppliers, and manufactured to be operated within single station. Seoul Metro has been planning to implement the integrated control system to secure seamless train operation and safety and to have a fast response system against emergency situations such as PSD failure and fire, by implementing the system that is able to collectively manage, monitor and control the operation status and equipment conditions of PSD on to the integrated control center. This paper has studied a scheme to reduce the budget for the future facility constructions by standardizing the data format for data communication with the integrated station control panel and using the open standard protocols, in order to secure consistency of operation, system expansion and maintenance with unified and standardized control items.

  • PDF

지하철 승강장 급배기 조건에 따른 화재 위험성 평가 (Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions)

  • 김하영;이동호;김정엽
    • 한국화재소방학회논문지
    • /
    • 제22권5호
    • /
    • pp.29-34
    • /
    • 2008
  • 본 연구에서는 대피자의 최적 배연조건 확립을 위하여 CFD모델을 이용한 수치해석을 통해 지하철 승강장 내에서의 화재 시 다양한 배연조건에서의 화재 위험성을 검토하였다. 결과로 스크린도어를 설치한 경우가 설치하지 않은 경우보다 온도의 상승폭이 최대 $65.37%{\sim}74.97%$ 낮게 나타났다. 또한 급기나 압인배기시 승강장에 난류가 발생함에 따라 온도 및 연기층이 교란되어 하락됨에 따라 탈출시 위험을 유발할 수 있는 것으로 판단되었다. 따라서 배연용량 및 승강장 공간 설정시 배연조건에 따른 화재 특성을 고려한 설계가 필요하다.

수동 Mode에서 PSD System 최적화 연구 (A Study on PSD System optimization from manual mode)

  • 손영진;민경윤;이강원;방연근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.162-167
    • /
    • 2004
  • The ascent and descent market screen door (PSD-Platform Screen Door) between the electromotive car which is in the process of operating from the subway ascent and descent market and the passenger it is an immediacy and crisis as the system which it intercepts currently the inside and outside of the country of course signal system automatic operation signal system (ATO) establishment is operated from the segment. Manual operation signal system (the ATS and the ATC) almost it is a condition which is wholly lacking from the segment. This year from second half of the year 2 line manual operation signal system (ATS). It established the shutting tightly elder brother and the railing elder brother in PSD system in segment 12 reverses and the death accident due to the passenger hurt accident which occurs from the subway. It prevented an energy curtailment in the same time when it raises air cooling efficiency, It gathered it restricted the underground space which is comfortable in the use citizen and and and service it did interface the electromotive car and PSD entrance and exit literature course from the manual operation segment to sleep technically optimizationt. It researched a minute dust diffusion.

  • PDF

항해장비 표준화모드 지침 개발을 위한 사용자 선호도 조사에 관한 연구 (A Study on User Preference Test for Development of Guidelines on Standardized Modes)

  • 안영중;전계정;정재훈;강남선
    • 한국항해항만학회지
    • /
    • 제42권6호
    • /
    • pp.371-377
    • /
    • 2018
  • 항해장비 표준화 모드는 안전항해에 필요한 정보들을 신속 정확하게 확인하기 위하여 주요 항해장비의 핵심기능과 화면표시, 작동법등을 표준화하는 기능이다. 국제해사기구는 표준화 모드의 항해장비 적용을 위한 지침 개발을 항해통신수색구조위원회의 과업으로 배정하여 진행 중에 있다. 본 연구는 표준화 모드 적용에 대한 실제 사용자들의 의견과 선호도를 조사하여 지침 개발에 반영하기 위해 수행되었다. 항해장비 중 ECDIS를 대상으로, 항해 업무를 수행하기 위해 필수적 또는 우선적으로 요구되는 정보 및 기능의 종류, 화면 구성, 메뉴트리의 사용자 선호도 조사를 위한 테스트 프로그램을 구성하였다. 웹 기반의 테스트 프로그램을 통해 35개국 333명의 선호도 조사를 실시하였으며, ECDIS 사용자들이 항해당직 수행 시 선호하는 다양한 ECDIS 정보의 내용과 화면배치들을 확인하였다. 연구의 결과는 표준화 모드에 고려할 사용자 요구 사항을 제시하여, 실효성 있는 지침 개발에 기여할 수 있을 것이다.

지하철 승강장 형식에 따른 정량적 화재 위험성 평가 (Quantitative Fire Risk Assesment for the Subway Platform Types)

  • 이동호;김하영
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.