• 제목/요약/키워드: Screen X

검색결과 323건 처리시간 0.021초

Electrical Properties of Co- and Cu-Doped Nickel Manganite System Thick Films for Infrared Detectors

  • Lee, Dong-Jin;Lee, Sung-Gap;Kim, Kyeong-Min;Kwon, Min-Su
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.261-264
    • /
    • 2017
  • $Ni_{0.79}Co_{0.15-x}Cu_xMn_{2.06}O_4$ ($0{\leq}x{\leq}0.09$) thick films were fabricated using the conventional solid-state reaction method and screen-printing method. Structural and electrical properties of specimens based on the amount of Cu were observed in order to investigate their applicability in the infrared detector. All specimens showed a single spinel phase with a homogeneous cubic structure. As the amount of Cu increased, the average grain size increased and was found to be approximately $5.01{\mu}m$ for the $Ni_{0.79}Co_{0.06}Cu_{0.09}Mn_{2.06}O_4$ specimen. The thickness of all specimens was approximately $55{\sim}56{\mu}m$. As Cu content increased, the resistivity and TCR properties at room temperature decreased, and these values for the $Ni_{0.79}Co_{0.06}Cu_{0.09}Mn_{2.06}O_4$ specimen were $502{\Omega}-cm$ and $-3.32%/^{\circ}C$, respectively. The responsivity and noise properties decreased with an increase in Cu content, with the specimen with a Cu content of x=0.09 showing 0.0183 V/W and $5.21{\times}10^{-5}V$, respectively.

무지외반증 환자의 증상정도의 자동분류 알고리즘 개발 (Algorithm development of automatic symptom degree for Patient with Hallux Valgus)

  • 한현지;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권2호
    • /
    • pp.96-102
    • /
    • 2011
  • 본 연구에서는 현대인의 대표적 발 질환 중 하나인 무지외반증의 증상정도 자동 분류 알고리즘 개발에 대한 연구를 수행하였다. 무지외반증의 치료 및 수술을 위한 기존 아날로그적 진단법이 아닌 디지털 영상처리기법을 사용함으로써 효과적인 자동화 진단법을 제시하였다. 이를 위해 본 연구에서는 각각 정상인과 무지외반증 환자의 X-Ray 영상을 이용하였다. 우선 정상인의 X-Ray 영상에 정상 각도를 오버랩과 애드 방법을 통하여 기준각도를 표시한 후, 윤곽선 검출 알고리즘인 로버츠 필터와 세선화 작업을 거쳐 통칭 정상인 기준 영상을 만들었다. 그리고 진단할 환자의 X-Ray 영상에 윤곽선 검출 알고리즘인 소벨 필터를 거쳐 환자 영상을 만들어 앞서 언급한 정상인 기준 영상과 오버랩과 애드 방법을 통하여 디스플레이 출력 영상을 구현하였다. 디스플레이 출력 영상을 이용하여 무지외반증 진단 각도를 측정하여 화면에 디스플레이 함으로써 기존의 아날로그적 진단법에서 탈피한 디지털적 영상처리 진단법을 제시하였으며 그 실용성과 타 정형외적 질환의 응용성을 확인하였다.

형광지를 이용한 물품검사 X-선 DR 영상처리 시스템 개발 (The development of product inspection X-ray DR image processing system using intensifying screen)

  • 박문규;문하정;이동훈
    • 한국정보통신학회논문지
    • /
    • 제19권7호
    • /
    • pp.1737-1742
    • /
    • 2015
  • 물품 검사를 위한 산업현장에서는 물품의 표면뿐만 아니라 내부 부품결함 검사 또한 필요하다. 일반적으로 생산 공정에서의 물품 검사로 광학 검사를 많이 이용한다. 하지만 이는 표면상의 결함만을 검사할 뿐 물품 내부의 검사를 수행하기는 어렵다. 이러한 제한점을 극복하기 위해 광학 장치 대신 휴대용 X-선 DR 영상 획득 장치를 이용하여 영상을 실시간으로 얻는 동시에 제품 불량을 판별할 수 있는 시스템을 개발하였다. X-선 영상을 얻은 후 머신영상 처리를 통해 설정한 기준 값에 오차범위를 허용하면 통과, 그렇지 않으면 불량으로 인식되도록 시스템을 개발하였다. 또한, 물품의 불량 유무 결과와 그 수치는 사용자가 저장할 수 있도록 하였다.

초경량 고정익무인항공기 사진측량기법의 정사영상 정확도 평가 (Orhtophoto Accuracy Assessment of Ultra-light Fixed Wing UAV Photogrammetry Techniques)

  • 이인수;이재원;김수정;홍순헌
    • 대한토목학회논문집
    • /
    • 제33권6호
    • /
    • pp.2593-2600
    • /
    • 2013
  • 본 연구는 최근 국내외에서 문화재 보존, 사고현황조사, 군 정찰업무, 재난관리 등 다양한 분야에서 활용되고 있는 초경량 고정익무인항공기 사진측량의 성능평가를 다루고자 한다. 항공삼각측량 결과, 위치(X, Y)에서 RMSE 값은 약 10 cm로 나타났으며, UAV 사진측량의 정사영상에 대한 시각판독법(on-screen digitizing) 기법과 지상측량에 의한 필계점 좌표 차의 RMSE 는 X 방향 약 0.174~0.205 m, Y방향 약 0.294~0.298 m의 편위형 오차가 도출되었다. 그리고 실험대상지역의 임의의 1 필지를 대상으로 지적 공부대장면적과 UAV 사진측량의 정사영상으로 취득한 필지 면적을 비교한 결과 차이는 0.118 $m^2$이다. 본 연구는 초경량 고정익무인항공기 사진측량의 정사영상 정확도 평가에 대한 하나의 연구 사례를 제시하였으며, 향후 항공삼각측량(AT), 직접 기하보정(direct-georeferencing), 비행계획, 그리고 실용적 응용분야 개발 등에 대한 연구가 지속되어야 할 것으로 판단된다.

부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구 (A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan)

  • 전성오;조영하
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

국내 특수상영관 포맷별 기술현황과 개선방향 (Technology Status and Improvement Direction of Special Theaters in Korea by Format)

  • 정현진
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제15권4호
    • /
    • pp.73-87
    • /
    • 2021
  • 특수상영관은 일반상영관보다 차별화된 스크린, 음향, 좌석 시설과 고급화된 서비스, 확장된 화면으로 인한 몰입감과 스펙터클을 제공하기 위해 생겨난 상영관이다. 본 연구에서는 특수상영관에서 상영되는 포맷인 3D 영화, 4DX, 아이맥스, 스크린X, VR의 기술적 특성에 대해 비교 분석해보고 이를 바탕으로 제작 기술 한계점을 파악, 극복 방향에 대해 제언해 보고자 한다. 다양한 포맷은 상영 기술에 따라 화각에서 차이점을 보이게 되고 이러한 차이점은 영화의 미장센, 내러티브, 편집을 달라지게 해 결과적으로 제작 환경과 과정에까지 변화를 가져온다. 따라서 연출, 창작자들은 새로운 포맷들의 이전과는 다른 기술적 특징과 한계를 충분히 인지하고 접근해야 한다. 그러나 새 포맷은 대부분 기술 교육과 계승의 폐쇄성으로 인해 각 제작 현장에서 결국 한계에 부딪히고 만다. 특수 카메라 촬영이 필수적인 상황에서 기획단계에서부터 각 포맷의 특징을 충분히 고려한 제작이 이루어져야 하는데, 제작 기간, 제작비의 증가로 인해 재정적 문제도 발생하게 된다. 이러한 다양한 장애를 극복하기 위해서는 먼저 포맷별 제작 현장에 대한 깊이 있는 연구를 통해 문제점 파악과 대안 제시가 필수적이다. 또한, 일반적인 2D 영화가 오랜 역사를 쓰며 행했던 심도 있는 미학적, 영화적 사유를 새 포맷에서도 할 수 있도록 각 포맷에 맞는 내러티브를 만드는 노력이 필요하다. 본 연구를 통해 각 포맷의 원형인 기술에 대해 알아보고 제작 기술의 현주소를 파악하며, 이를 바탕으로 어떻게 포맷이 변화되는지 분석하고자 한다.

X-선촬영 조사 조건하에서 다결정 요오드화수은 박막검출기의 신호특성 분석 (Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition)

  • 김종언
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.289-294
    • /
    • 2010
  • 이 연구의 목적은 다결정 요오드화수은 박막검출기를 제작하여 X-선촬영 조사 조건하에서 검출기 성능의 평가이다. 두께 210과 $320 \;{\mu}m$를 갖는 다결정 요오드화수은 박막검출기들은 스크린 프린트 기술로 제작하였다. X-선 감도와 암전류의 측정들은 두 검출기에 대하여 수행하였다. 그리고 X-선 반응의 선형성과 재현성의 측정들은 두께 $320 \;{\mu}m$의 검출기에 대하여 수행하였다. 두께 $320 \;{\mu}m$의 검출기에 인가된 0.05에서 $2\;V/{\mu}m$까지의 전기장 강도들에 대하여, X-선 감도들은 233에서 $1,408{\times}10^6\;electrons/mR{\cdot}mm^2$까지 측정되었다. 그리고 암전류들은 3.2에서 $118\;pA/mm^2$까지 측정되었다. Zhong Su 등에 의해 보고된 값들과 비교에서, X-선 감도들은 Zhong Su 등에 의해 측정된 X-선 감도들보다 약 2배 더 크게 나타냈다. 그리고 암전류들은 Zhong Su 등에 의해 측정된 암전류들보다 약 9배 더 크게 나타냈다. X-선 반응의 선형성은 상관계수(r)로서 0.988을 얻었다. 재현성은 변동계수로서 0.002를 얻었다. 이 연구는 X-선촬영 조사 조건하에서 능동매트릭스 평판영상장치에 사용할 수 있는, 제작된 다결정 요오드화수은 박막검출기의 성능 데이터를 제공한다.

유연한 Gd2O2S:Tb 증감지 제작 및 피로누적에 대한 영향 (Fabrication of Bendable Gd2O2S:Tb Intensifying Screen and Evaluation of Fatigue Properties)

  • 박지군;양승우;전제훈;김주희;허예지;강상식;김교태
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.611-617
    • /
    • 2017
  • 본 연구에서는 연성을 형광체 층이 가질 수 있다면 외부의 기계적 외력에 대하여 장기간 안정성을 확보할 수 있을 것으로 기대하였다. 이에 본 연구에서는 스크린 프린팅 공법을 통하여 유연한 $Gd_2O_2S:Tb$ 증감지를 제작하였고 장기적인 외력에 의한 피로누적과 반복적인 외력에 의한 피로누적에 따른 영향을 고찰하고자 RMS 분석과 히스토그램을 분석을 통하여 영상 균일도를 평가하였다. 연구 결과, 지속적인 외력에 대하여는 지배적인 픽셀 영역이 일정하게 유지되면서 RSD가 10% 이내를 만족하였으나, 반복적인 외력의 경우 지배적인 픽셀 영역이 3 영역으로 분할되며 영상 균일도에 악영향을 미치며 RSD가 10% 이상으로 증가하는 것으로 나타났다. 이러한 결과를 바탕으로 기존 방사선증감지에 대비하여 기계적 안정성을 확보함으로써 곡면 검출기의 적용 가능성을 제시하였으나 아직까지 플렉시블 검출기에 적용하기 위해서는 추가적인 연구가 필요할 것으로 사료된다. 이러한 결과 유연성을 가진 방사선 증감지는 다양한 곡면에 적용이 가능하므로 향후 핵의학, 치료용, 산업 분야 등과 같은 다양한 분야에 적용할 수 있을 것으로 기대된다.

문화재 방사선 조사에서 발생하는 산란 방사선의 특성과 영향 (Characteristics and Influence of Scattering Radiation in Cultural Heritage Radiography)

  • 송정일;박영환;유지혜
    • 보존과학회지
    • /
    • 제34권6호
    • /
    • pp.539-548
    • /
    • 2018
  • 본 연구는 문화재 방사선 조사에서 고려하지 않았던 산란 방사선의 영향을 확인하기 위해 관전압 (kVp)과 필름-바닥 거리(film-floor-distance: FFD) 납스크린 배치를 달리하여 평가하였다. 연구결과, 실험시편의 투과농도와 산란 방사선의 투과 농도는 관전압에 따라 증가되었다. 실험시편의 투과농도는 평균 1.4 D의 편차를 보이며, 60 kVp에서 0.17 D, 160 kVp에서 1.54 D, 220 kVp에서 2.97 D로 확인되었다. 산란 방사선의 평균 투과농도는 60 kVp에서 0.10 D, 160 kVp에서 0.40 D, 220 kVp에서 0.46 D로 확인되었다. FFD 거리가 바닥면과 멀어질수록 관전압(60 kVp-160 kVp)구간의 경우 투과농도 (D)가 커지는 경향을 보였으나, 고전압(160 kVp-220 kVp)구간은 FFD 거리 증가에 따른 투과농도 변화가 확인되지 않았다. 납스크린 없는 조건과 바닥면(floor)을 납스크린으로 대체한 경우는 FFD 50 mm, 100 mm, 200 mm 거리에서 산란 방사선이 확인되었고, FFD 0 mm 거리는 확인되지 않았다. 식별률은 관전압 160 kVp에서 FFD에 따라 2.08~2.67% 범위이며, 관전압 220 kVp에서는 2.67~3.33% 범위로 측정되었다.

X선용 545 nm 형광판 결상광학계 개발 (Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray)

  • 이동희
    • 한국안광학회지
    • /
    • 제13권2호
    • /
    • pp.17-22
    • /
    • 2008
  • 목적: X선용 545 nm 형광판을 위한 결상광학계 개발. 방법: 캐논(Canon)사 CX2-70 모델을 참조하여 설계 기준을 정한 다음 Sigma 2000 광학 설계 프로그램으로 X선용 545 nm 형광판을 위한 결상광학계를 설계 제작하였다. 결과: 새로 설계 제작되어진 X선용 545 nm 형광판 결상광학계의 배율은 -0.225배이고, 이미지 크기는 90 mm${\times}$90 mm이며, 분해선폭은 30% MTF 값 기준으로 0.033 mm인 특성을 보여준다. 이는 캐논 CX2-70 모델보다 큰 화면으로 판독을 할 수 있고, 판독의 분해능도 우수함을 의미한다. 또한 이미지 측 NA값이 -0.196으로 캐논 CX2-70 모 델 -0.139보다 약$\sqrt{2}$배 크게 하였고, 물체 측 NA값도 0.044로 캐논 CX2-70 모델 0.022보다 약 2배 크게 하였다. 이는 필름의 감도를 4배 증가 시킬 수 있는 것을 의미하며 X선의 피폭시간을 1/4로 줄일 수 있음을 뜻한다. 결론: 이미지 크기가 90 mm${\times}$90 mm이고, 15 lines/mm에서 MTF 30% 이상인 특성을 가지며, 캐논 CX2-70 모델에 비해 X선 피폭시간을 1/4로 줄일 수 있는 새로운 X선용 545 nm 형광판 결상광학계를 설계 제작하였다.

  • PDF