Sensitivity of GAGG based scintillation neutron detector with SiPM readout

  • Fedorov, A.;Gurinovich, V.;Guzov, V.;Dosovitskiy, G.;Korzhik, M.;Kozhemyakin, V.;Lopatik, A.;Kozlov, D.;Mechinsky, V.;Retivov, V.
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2306-2312
    • /
    • 2020
  • Here we report on the first results of sensitivity evaluation of the gadolinium-aluminum-gallium- garnet (GAGG) scintillation detector with SiPM readout to fast and slow neutrons and, to the natural background and Co-60 γ-radiation as well. Data on sensitivity were obtained using certified dosimetry benches, so it can be utilized in the calculation of detection limits of neutron flux with such type of detectors. It was concluded that use of GAGG scintillator has a good prospect for neutron monitoring in different parts of nuclear research reactors and power plants.

방사선 분포측정용 CsI(Tl) 검출기 설계 및 신호처리에 관한 연구 (The Study of CsI(Tl) Scintillation Detector Design and Signal Processing for the Measurement of the Radiation Distribution)

  • 황영관;이남호;김종열;정상훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.778-779
    • /
    • 2016
  • 본 논문에서는 공간상에 분포된 방사선원에 대해 화소단위로 방사선 신호를 탐지하기 위한 섬광 검출기를 설계하고, 탐지신호를 취득하기 위한 모듈을 설계하여 방사선 영상화를 위한 연구를 수행하였다. 방사선 분포측정을 위해 적용한 검출기는 CsI(Tl) 섬광체와 결합효율이 높은 수광센서로 구성하였으며, 수광센서를 통해 획득된 신호를 처리하기 위해 펄스 신호를 증폭, 성형 한 후 임계치를 기준으로 펄스를 계수하기 위한 장치를 구현하였다. 제작된 검출기의 성능을 검증하기 위해 감마선 교정시설을 이용하여 검출기에 대한 성능 시험을 수행하고 그 결과를 분석하였다. 본 논문의 결과는 제작된 검출기에 방향성을 부여하기 위한 차폐체 및 조사부를 적용한 후 방향을 이동시켜 개별적인 영역의 값을 2차원 적으로 나타냄으로써 선원의 분포측정을 위한 기초자료로 활용될 것이다.

  • PDF

원통형 NaI(Tl) 신틸레이션 검출기를 이용한 거리의 역자승 법칙에서 효율 오류에 대한 연구 (A Study on Efficiency Error in Distance Inverse Square Law using Cylinder NaI(Tl) Scintillation Detector)

  • 이삼열;윤정란;노태익
    • 한국방사선학회논문지
    • /
    • 제7권5호
    • /
    • pp.333-338
    • /
    • 2013
  • 일반적으로 방사선 선원의 강도는 거리의 역자승 법칙을 따른다. 그러나 방사선 선원과 검출기와의 거리가 가까울수록 거리의 역자승 법칙 실험은 이론과 실험의 일치하지 못하는 오류를 가져오게 된다. 본 연구에서는 방사선 선원과 검출기와의 거리에 따른 거리의 역자승 법칙이 실제 실험에서는 정확하게 성립하지 않는 이유를 실험적으로 확인하였다. 그리고 이 문제를 해결하기 위하여 측정된 방사능을 보정하기 위하여 보정계수를 실험적으로 얻었다. 측정에 사용한 검출기는 $2^{{\prime}{\prime}}{\times}2^{{\prime}{\prime}}{\phi}$ NaI(Tl) 신틸레이션 검출기를 사용하였고, 방사선에너지의 변화에 따른 효과를 확인하기 위하여 감마선 선원 $^{60}Co$(1.174 MeV, 1.333 MeV)와 $^{137}Cs$(0.662 MeV)에 대한 실험도 병행하였다. 측정에서 얻어진 거리의 역자승 법칙의 결과들을 보정계수를 이용하여 측정값들을 보정한 결과 거리의 역자승 법칙과 매우 일치하는 경향을 보였고, 오류에 대한 원인을 실험적으로 확인하였다. 이러한 결과는 유한한 체적을 가진 검출기를 사용하여 방사선의 강도가 거리의 역자승에 반비례하는 실험을 할 경우 모두 해당되는 문제이므로 본 연구의 결과는 방사선계측 분야에 매우 유용하게 사용되어질 것으로 사료된다.

최대우도함수를 이용한 양전자방출단층촬영기기의 검출기 모듈의 디지털 위치 획득 방법 (Digital Position Acquisition Method of PET Detector Module using Maximum Likelihood Position Estimation)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2021
  • 양전자방출단층촬영기기에서 영상을 획득하기 위해서는 동시 측정된 검출기 모듈의 섬광 픽셀의 위치 좌표를 서로 연결하는 과정이 필요하다. 이를 위해서 다수의 섬광 픽셀과 소수의 광센서를 사용하는 검출기 모듈에서는 평면 영상을 획득하여 각 섬광 픽셀의 영역을 나누어 감마선과 상호작용한 섬광 픽셀의 위치를 획득해야 한다. 또는 사용하는 섬광 픽셀의 수와 광센서의 수를 동일하게 구성할 경우는 섬광 픽셀 위치에 대한 위치 좌표를 직접 디지털 신호 좌표로 획득할 수 있다. 다수의 섬광 픽셀과 소수의 광센서를 사용하는 방법은 평면 영상 획득과 영역을 나누는 과정이 필요하며, 디지털 신호 좌표를 직접 획득하는 방법은 다수의 광센서와 신호처리 시스템이 필요하다. 이는 신호처리 과정이 복잡해지며, 비용이 상승하는 문제가 발생한다. 이를 해결하기 위해 본 연구에서는 다수의 섬광 픽셀과 소수의 광센서를 사용하여 평면 영상 및 영역의 분리과정을 수행하지 않고 디지털 신호 좌표를 획득하는 방법을 개발하였다. 최대우도함수를 사용하여 각 섬광 픽셀에서 획득한 신호를 통해 작성된 순람표를 통해 감마선과 상호작용한 섬광 픽셀의 위치 좌표값을 디지털 신호로 획득하는 방법이다. DETECT2000을 사용하여 시뮬레이션을 실시하였으며, 제시한 방법에 대해 검증을 실시하였다. 그 결과 모든 섬광 픽셀에서 정확한 디지털 신호 좌표를 획득할 수 있었으며, 이를 기존 시스템에 적용할 경우 신호처리 과정의 단순화로 보다 빠른 영상획득이 가능할 것으로 판단된다.

다수의 광가이드를 통한 빛 분포 설계로 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 설계 (Two Layer DOI Detector Design for PET using Multiple Light Guides for Designing Light Distribution)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.703-708
    • /
    • 2022
  • 양전자방출단층촬영기기(positron emission tomography, PET)의 공간분해능 향상을 위한 반응 깊이를 측정하는 검출기를 설계하였다. 섬광 픽셀 배열이 두 층으로 구성되며, 층 사이에는 감마선 이벤트를 통해 발생된 빛을 각 층별 서로 다른 분포로 만들기 위해 광가이드를 삽입하였다. 광가이드는 4개로 구성되며 하나의 광가이드는 2 × 2 배열의 섬광 픽셀과 연결되도록 설계하였다. 위층에서 발생된 빛은 광가이드를 통해서 더 넓은 분포로 광센서로 이동되며, 아래층에서 발생된 빛은 위층보다 좁은 분포로 광센서에 입사한다. 서로 다른 분포에 의해 광센서에서 획득되는 신호를 바탕으로 평면 영상을 재구성하면 층별 서로 다른 위치에 섬광 픽셀이 영상화된다. 이를 검증하기위해 섬광체내에서 빛의 거동을 모사하는 DETECT2000 시뮬레이션 툴을 사용하였다. 섬광 픽셀 배열과 광가이드 및 광센서로 이루어진 검출기를 설계하여, 모든 섬광 픽셀에서 감마선 이벤트를 발생시켜 평면 영상을 획득하였다. 그 결과 위층과 아래층은 서로 다른 위치에서 영상화되었으며, 완벽히 구별되는 것을 확인할 수 있었다. 본 검출기를 PET에 적용할 경우 보다 향상된 공간분해능을 통해 영상의 질을 향상시킬 수 있을 것으로 판단된다.

A technique for the reduction of pulse pile-up effect in pulse-shape discrimination of organic scintillation detectors

  • Nakhostin, M.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.360-365
    • /
    • 2020
  • A technique for the reduction of pulse pile-up effect in digital pulse-shape discrimination (PSD) of neutrons and gamma-rays with organic scintillation detectors is presented. The technique is based on an electronic reduction of the effective decay-time constant of scintillation pulses while retaining the PSD information of the pulses. The experimental results obtained with a NE213 liquid scintillation detector in a mixed radiation field of neutrons and gamma-rays are presented, demonstrating a figure of merit (FOM) of 1.20 ± 0.05 with an energy threshold of 350 keVee (electron equivalent energy) when the effective length of the pulses is reduced to 50 ns.

방사선 검출신호의 시계열 분석에 관한 연구 (A Study on Time Series Analysis for the Detector Pulses of Radiation)

  • 홍석붕;정종은;김용균;문병수;권기호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.282-282
    • /
    • 2000
  • The analysis of the radiation effect on matter has been performed using stochastic methods. Recently, It was discovered that the detector pulses of radiation can be analysed using deterministic method that utilizes the chaotic behaviour with an attractor found in a noise region. We acquired a time series for pulse tram of Am-241 using scintillation detector and reconstructed a phase space, then performed new analysis for the radiation detection signal by applying embedding theory, Lyapunov exponent, correlation dimension, autocorrelation dimension, and power spectrum.

  • PDF

$BaF_2$ 검출기의 시간과 에너지 특성연구 (A Study on the Energy and Time Characteristics of $BaF_2$ Scintillation Detector)

  • 주관식;박일진;김종호;남기용;백승화
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.267-272
    • /
    • 1997
  • 3.6cm${\times}$2.0cm (지름 ${\times}$ 두께) 크기의 $BaF^2$ 섬광체로 검출기를 제작하여 감마 카메라등 의료용 진단장치에서 센서로 사용되고 있는 NaI(씨)검출기와 방사선 검출특성을 비교하여 보았다. 특정에 사용된 선원은 $^{22}Na,\;^{54}Mn,\;^{57}Co,\;^{137}Cs$${\gamma}$선 방출선원으로 검출기와 선원간의 거리를 7cm로 유지하였다. 시간특성을 분석하기 위하여 511keV의 양전자 방출선원을 사용하여 NaI(Tl)(1" ${\times}$ 1"), NaI(Tl)(3" ${\times}$ 3")순으로 $BaF^2$가 가장 빠르게 나타났으며, $BaF^2$ 검출기의 효율은 500keV에서 가장 높게 측정되었다.

  • PDF

Efficient design of a ∅2×2 inch NaI(Tl) scintillation detector coupled with a SiPM in an aquatic environment

  • Kim, Junhyeok;Park, Kyeongjin;Hwang, Jisung;Kim, Hojik;Kim, Jinhwan;Kim, Hyunduk;Jung, Sung-Hee;Kim, Youngsug;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1091-1097
    • /
    • 2019
  • After the Fukushima accident in 2011, there has been increased public concern about radioactive contamination of water resources through fallout in neighboring countries. However, there is still no available initial response system that can promptly detect radionuclides. The purpose of this research is to develop the most efficient gamma spectrometer to monitor radionuclides in an aquatic environment. We chose a thallium-doped sodium iodide (NaI(Tl)) scintillator readout with a silicon photo multiplier (SiPM) due to its compactness and low operating voltage. Three types of a scintillation detector were tested. One was composed of a scintillator and a photomultiplier tube (PMT) as a reference; another system consisted of a scintillator and an array of SiPMs with a light guide; and the other was a scintillator directly coupled with an array of SiPMs. Among the SiPM-based detectors, the direct coupling system showed the best energy resolution at all energy peaks. It achieved 9.76% energy resolution for a 662 keV gamma ray. Through additional experiments and a simulation, we proved that the light guide degraded energy resolution with increasing statistical uncertainty. The results indicated that the SiPM-based scintillation detector with no light guide is the most efficient design for monitoring radionuclides in an aquatic environment.