• Title/Summary/Keyword: School Dust

Search Result 540, Processing Time 0.028 seconds

INFRARED SPECTRAL ENERGY DISTRIBUTION OF GALAXIES IN THE AKARI ALL SKY SURVEY: CORRELATIONS WITH GALAXY PROPERTIES AND THEIR PHYSICAL ORIGIN

  • Makiya, R.;Totani, T.;Takeuchi, T.T.;Nagashima, M.;Kobayashi, M.A.R.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.325-329
    • /
    • 2012
  • We will report our recent study on the properties of more than 1,600 galaxies detected by the AKARI All-Sky Survey with physical quantities based on optical and 21-cm observations, to understand the physics determining the infrared spectral energy distribution (Totani et al., 2011). We discover a tight linear correlation for normal star-forming galaxies between the radiation field strength of dust heating (corresponding to dust temperature) and the galactic-scale infrared radiation field, $L_{TIR}/R^2$. This is the tightest correlation of dust temperature ever known, and the dispersion along the mean relation is 13% in dust temperature. This relation can be explained physically by a thin layer of heating sources embedded in a thicker, optically-thick dust screen. We also find that the number of galaxies sharply drops when galaxies become optically thin against dust-heating radiation, indicating that a feedback process to galaxy formation (e.g., by the photoelectric heating) is working when dust-heating radiation is not self-shielded on a galactic scale. We discuss implications from these findings for the $M_{H_I}$ -size relation, the Kennicutt-Schmidt relation, and galaxy formation in the cosmological context.

Climatic Features of Extratropical Cyclones During the Spring-time Yellow Dust Events in Korea (한반도 봄철 황사 발생시 동아시아 온대저기압의 기후학적 특징)

  • Lee, Jaeyeon;Kim, Junsu;Son, Seok-Woo
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.565-576
    • /
    • 2016
  • The yellow dust events in Korea are often associated with extratropical cyclones (ETCs) that travel across the source regions of yellow dusts. Although such synoptic patterns are well documented, climatic features of ETCs themselves during the yellow dust events are not well understood. The present study reports climatic features of spring-time ETCs, which accompany the yellow dust events in Korea, by tracking individual ETCs with an automated tracking algorithm. By analyzing Lagrangian tracks of ETCs from 1979 to 2014, it is found that, during yellow dust events, ETCs are located around Vladivostok, Russia. They are typically originated from the leeside of Altai-Sayan mountains about three days before the onset of the yellow dust events, and travel either eastward or southeastward in time. While their tracks are not unusual, they grow faster over the source regions of the yellow dusts, possibly lifting desert dusts above the planetary boundary layer, and further develop slowly as they travel eastward.

The Effects of Micro-Environmental Factors on the House Dust Mite

  • Jo, Wan-Je;Sohn, Jang Yeul
    • Architectural research
    • /
    • v.9 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • The proliferation of the House Dust Mite(HDM) is affected by temperature, humidity, ventilation, etc. Measuring temperature and humidity was performed at the very location where dust samplings take place and where they live in reality together with temperature and humidity of the ambient of the room. There has been discussion over the key environment factor of HDM survival; absolute humidity or relative humidity. It seems that relative humidity is the more important determinant for the mite's survival through the analysis of previous studies. Temperature, humidity, ventilation rate and Der P1 were measured in 4 flats in London. Mite allergen was detected in every house. Levels of Der P1 varied between <100ng/g and 22,778ng/g. Flats with high relative humidity(>50%) and poor ventilation(<0.5ach) showed higher levels of mite allergen than flats with lower humidity and adequate air change rate. Questionnaire survey was conducted and the result helped to confirm the findings from monitoring of environmental factors and the dust sampling.

Effects of SiO2 in Turkish Natural Stones on Cancer Development

  • Dal, Murat;Malak, Arzu Tuna
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.4883-4888
    • /
    • 2012
  • In materials science, one of the new concerns in the construction industry, it is well established that mineral dust from rocks (stones) has adverse effects on human health. For instance, it is suspected that some mineral dusts in particular leads to occupational diseases, including lung cancer. The present research concerned the relationship between cancer and those workers who work in Turkish construction industry and quarries and are exposed to silica mineral dust from natural stones. One focus was cancer prevention methods applied in-site. In mining and construction industry where stone dust is widely used, silicosis induced lung cancer is frequently seen. Cancer cases which are seen across the regions mostly affected by silica containing dust in Turkey were identified and a survey was conducted of the methods to protect workers in the construction industry from exposure to silica dust.

INFRARED OBSERVATIONS OF DUST AROUND HELIUM NOVA V445 PUPPIS

  • Shimamoto, Sayaka;Sakon, Itsuki;Onaka, Takashi;Usui, Fumihiko;Ootsubo, Takafumi;Doi, Yasuo;Ohsawa, Ryou;Ishihara, Daisuke
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.109-111
    • /
    • 2017
  • We detected bright mid- to far-infrared emission from the helium nova V445 Puppis in the AKARI all-sky survey data taken in 2006. Assuming an optically thin condition, we decomposed the spectral energy distribution (SED) of V445 Puppis in October 2006 by model fitting and found that the SED can be explained by a combination of cold amorphous carbon (125 K and the mass of $4.5^{+6.6}_{-2.7}{\times}10^{-4}M_{\odot}$) and warm amorphous carbon (250 K and the mass of $1.8^{+1.0}_{-0.5}{\times}10^{-5}M_{\odot}$). Assuming that the former is pre-existing dust formed in the past nova outbursts and the latter is newly formed dust in December 2000's nova wind, this result suggests that the amount of dust formed around V445 Puppis in a single outburst is larger than $10^{-5}M_{\odot}$, which is larger than those in any other classical novae ever reported.

Analysis of Quartz Content and Particle Size Distribution of Airborne Dust from Selected Foundry Operations (주물사업장 주공정별 발생하는 분진의 석영함유량 및 크기분포 연구)

  • Phee, Young Gyu;Roh, Young Man;Lee, Kwang Mook;Kim, Hyoung-Ah;Kim, Yong Woo;Won, Jeoung Il;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.196-208
    • /
    • 1997
  • This study was performed to estimate quartz contents in the both bulk and airborne dust samples and to determine particle size distribution of airborne dust from the selected foundry operations. Total dust samples were collected by a 37mm cassette and respirable by a 10 mm nylon cyclone. Particle size distributions were determined by a Marple's 8-stage cascade impactor at the melting, molding, shakeout and finishing operations. The presence of elements in the dust samples were confirmed by the scanning electron microscopy equipped with the energy dispersive x-ray spectrometry. The quartz contents were estimated using the intensity of the absorption peak of quartz at 799 cm-l by the Fourie Transformed Infrared Spectroscopy (FTIR). The results were as follows: 1. The analysis of data from cascade Impactor showed bimodal distributions of particle size at the melting, molding and shakeout operations. Mass median aerodynamic diameters for the distributions determined by histogram were $0.48-1.65{\mu}m$ for small and $13.43-19.58{\mu}m$ for large modes. In the dust samples collected at the finishing operations, however, only a large mode of $18.89{\mu}m$ was found. 2. The percentages of total to respirable dust concentration calculated from the impactor data ranged from 42 % to 66 %. The average concentrations of respirable dust by cyclone were $0.85-1.28mg/m^3$ collected from the workers, and were $0.23-0.56mg/m^3$ from the areas surveyed. Dust concentrations of personal samples were statistically significantly higher than those of area samples. The highest dust concentration was obtained from the personal samples of the finishing operation. 3. The mean percentages of silicon and oxygen estimated by SEM-EDXA in the bulk samples ranged from 35.83 % to 36.02 % and from 39.93 %-41.64 %, respectively. 4. The average quartz contents estimated by FTIR in the respirable dust from personal samples ranged from 4.32 % to 5.36 % and 4.54 % to 4.70 % in the bulk samples. No statistical difference of quartz content was found between foundry operations. In this study, quartz content was quantified by FTIR. Although no statistically significant difference in quartz content between airborne and bulk, samples and between different foundry operations was found, it is recommended that quartz content in the individual sample of respirable dust be analyzed and the results be used either to select an applicable quartz limits or to calculate the exposure limit. Further studies, however, are needed to compare the results by FTIR and XRD since it is reported that the quartz content determined by FTIR is different from that by XRD.

  • PDF

Effect of a Resident and Indoor Environmental Characteristics on the House Dust Mites Allergen (주거환경 특성에 따른 집먼지진드기 항원량에 관한 조사)

  • Kim, Yong-Soon;Park, Jee-Won;Song, Young-Shin
    • Research in Community and Public Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.79-88
    • /
    • 2002
  • Purpose: The purpose of this study was to identify the indoor environment i.e. house type and age, ventilation method, use of bed & sofa, cockroach, ants, etc. on HDM (House dust mites), especially Der fI allergen. Method: Samples of dust from mattresses, pillows and the floor were collected by using a vacuum cleaner from April. 2000. The amount of Group I allergen(Der. fI) of HDM (house dust mites) were measured by two-site ELISA. Indoor Environmental characteristics were accessed by using questionnaires on 178 house wives living in the Seoul area. Results: The amount of HDM allergen (Der fI) was higher in sofa using house. There were higher concentrations of HDM allergen (Der fI) in sofas made from quilt material than for those that were made from leather. Homes that had pets like dogs living in them had higher concentrations of HDM allergen (Der fI) than without dogs. Conclusion: The photophobic mites thrive in dark. warm and humid environments; Items such as pillows. mattresses, box springs, blankets. carpets. and upholstered furniture should be considered ideal environments for the mite. Therefore, an indoor environmental control program should be carried out to avoid the HDM allergen.

  • PDF

Examining the Non-spherical Effect of Asian Dust Particle Onaerosol Optical Depth (황사의 비구형성이 에어러솔 광학적 두께 산출에 미치는 영향 연구)

  • Lee, Hyun-Ju;Kim, Sang-Woo;Yoon, Soon-Chang;Kang, Jung-Yoon
    • Atmosphere
    • /
    • v.22 no.2
    • /
    • pp.175-186
    • /
    • 2012
  • In this study, we investigate the effects of elliptical shape of Asian dust particles on the estimation of aerosol optical depth by implementing T-matrix method into WRF/Chem Dust Model. The phase function calculated by assuming elliptical particle shape near $110{\sim}160^{\circ}$ of scattering angle showed about 20 times larger than that calculated by assuming spherical particle shape. Significant difference of extinction efficiency was found with an increase of size parameter and aspect ratio. From the simulations of two Asian dust events occurred on 1 April 2007 and 16 March 2010, we found that the difference of extinction efficiency between elliptical and spherical particle shape was about 5~8%. The aerosol optical depth calculated by assuming elliptical particle shape with 1.6, 1.4 and 1.2 of aspect ratio was about $4.0{\pm}0.5%$, $2.0{\pm}0.2%$, and $1.0{\pm}0.1%$ larger than those estimated by assuming spherical particle shape.

Characteristics of Airborne and Deposited Dust in Expressway Toll Booths (고속도로 톨게이트 부스의 공기 중 분진 및 침착 분진 특성)

  • Nam, Mi Ran;Jung, Jong-Hyoen;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.10-17
    • /
    • 2020
  • Objectives: This study was performed to evaluate the total dust, size-selective dust, and heavy metal concentrations generated inside and outside toll booths on an expressway and to identify the source through analysis of the components of the deposited dust. Methods: A total of 32 samples were collected from eight expressway toll booths. Each total dust sample was collected using a 37 mm PVC filter attached to a personal air sampler. Heavy metal samples were collected according to NIOSH method 7300. The size-selective dust concentrations were identified using a DustMate, and deposited dust was analyzed by WD-XRF and UHR-FE-SEM. Results: The geometric mean concentrations of the total dust inside and outside the toll booths were 337.5 ㎍/㎥ and 342.7 ㎍/㎥, respectively. The overall concentrations of TSP, PM10, PM2.5, and PM1 were higher on the outside of the toll booths, as the particle size of dust was larger, and higher in the underground passage as the dust size was smaller. The real-time analysis of the dust concentrations of TSP, PM10, PM2.5, and PM1 revealed to be higher at morning and evening times than other times because of heavy traffic. The element components of deposited dust in the toll booth were related to natural sources rather than artificial sources. Among the chemical components in the deposited dust analyzed by WD-XRF, SiO2 was the highest. For the elements analyzed by UHR-FE-SEM, C was the highest, followed by O, and Si. Conclusions: In order to reduce the dust concentrations around toll booths on an expressway, it is necessary to periodically clean surrounding areas such as underground passages, and it is also necessary to remove deposited dust inside the toll booth from time to time.

Performance Characteristics of Louver Dust Collectors (루버 집진기의 성능특성)

  • Woo, Sang-Hee;Kim, Jong Bum;Park, Tong-Il;Yook, Se-Jin;Kwon, Soon Bark;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.11-20
    • /
    • 2016
  • A large amount of wear dust generated during train operation is a major dust source in urban railway tunnels. To check possibility of a louver dust collector for the removal of dust in the railway tunnel, five louver dust collector models were designed and their performance was tested in a wind tunnel. JIS Z 8901 Class 8 dust was used as a test dust. Pressure drop and particle collection efficiency were evaluated with the face velocity ranging from 1 m/s to 4 m/s. At this low velocity range, particle collection efficiency of the louver dust collector was found to be insensitive to air velocity and design parameters. Pressure drop was under 40 Pa, and $PM_{10}$ and $PM_{2.5}$ collection efficiencies were approximately 50% and 30%, respectively.