• 제목/요약/키워드: School Dust

검색결과 539건 처리시간 0.025초

중학교 학생들의 분진폭로에 관한 조사연구 (Student Exposure to Airborne Dusts in Classroom of Middle Schools)

  • 이영길;백남원
    • 한국환경보건학회지
    • /
    • 제13권2호
    • /
    • pp.25-33
    • /
    • 1987
  • This study was carried out to evaluate student exposures to dust in classroom of middle schools. A total of four schools, such as two in an urban and two in a rural area, were selected for this study. In this study, airborne dust concentrations were measured during a period from July 8 to July 18, 1986. Additional measurements of dust concentrations were conducted from November 4 to 7, 1986 to compare the results by seasonal variation. The results of this study were as follows. 1. Respirable dust concentrations were measured by both filtration method (C mg/m$^3$) and Digital Aerosol Monitor (cpm) to calculate anexchange factor K. K- value was 0.159 as follows. $K=\frac{c}{cpm} = \frac{2.71}{17.09} = 0.159$ 2. In summer when windows were opened, the concentrations of airborne respirable dusts measured by filter sampling method were 0.54-1.37 mg/m$^3$ in the morning and 0.79-1.75 mg/m$^3$ in the afternoon. Thus, higher levels were indicated in the afternoon. Meanwhile, the concentrations of airborne respirable dusts measured in winter were approximately twice as high as those in summer. 3. The highest dust concentrations were determined in School D which is a coeducational school with classroom of concrete floor. Walking roads in School D were not paved and students did not wear indoor-shoes. Dust levels in School D were approximately twice as high as levels in School B. All of the measured dust levels in four schools exceeded Korean Standard for outdoor air, 0.3 mg/m$^3$ for 24 hours. Results by Digital Aerosol Monitor indicated that there was no significant difference in dust levels among grades. The concentration of airborne dusts in the classroom was 1.5-3.0 times higher than that in the hall way. The concentration of airborne dusts during recess was 1.3-1.6 times higher than that during class. In winter, the dust concentrations during clean-up exceeded the permissible exposure limit, 10 mg/m$^3$ (as total dusts), for occupational exposures. 4. The concentrations of total dusts measured in winter were 1.5-2.4 times higher than those of respirable dusts measured simultaneously.

  • PDF

DEBRIS DISKS AND THE ZODIACAL LIGHT EXPLORED BY THE AKARI MID-INFRARED ALL-SKY SURVEY

  • Ishihara, Daisuke;Takeuchi, Nami;Kondo, Toru;Kobayashi, Hiroshi;Kaneda, Hidehiro;Inutsuka, Shu-ichiro;Oyabu, Shinki;Nagayama, Takahiro;Fujiwara, Hideaki;Onaka, Takashi
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.67-71
    • /
    • 2017
  • Debris disks are circumstellar dust disks around main-sequence stars. They are important observational clues to understanding the planetary system formation. The zodiacal light is the thermal emission from the dust disk in our Solar system. For a comprehensive understanding of the nature and the evolution of dust disks around main-sequence stars, we try a comparative study of debris disks and the zodiacal light. We search for debris disks using the AKARI mid-infrared all-sky point source catalog. By applying accurate flux estimate of the photospheric emission based on the follow-up near-infrared observations with IRSF, we have improved the detection rate of debris disks. For a detailed study of the structure and grain properties in the zodiacal dust cloud, as an example of dust disks around main-sequence stars, we analyze the AKARI mid-infrared all-sky diffuse maps. As a result of the debris disks search, we found old (>1 Gyr) debris disks which have large excess emission compared to their age, which cannot be explained simply by the conventional steady-state evolution model. From the zodiacal light analysis, we find the possibility that the dust grains trapped in the Earth's resonance orbits have increased by a factor of ~3 in the past ~20 years. Combining these results, we discuss the non-steady processes in debris disks and the zodiacal light.

2011년 봄 황사시기 제주도 고산에서의 황사와 오염입자의 광흡수 기여도 산정 (Estimation of the Light Absorption Contribution for Asian Dust and Polluted Particles at Gosan, Jeju during the Asian Dust Episode in the Spring 2011)

  • 이시혜;김상우;윤순창
    • 한국대기환경학회지
    • /
    • 제28권4호
    • /
    • pp.411-422
    • /
    • 2012
  • Ground-based in-situ measurements of aerosol optical properties at Gosan climate observatory have been analyzed to investigate the optical contribution of Asian dust and polluted particles on light absorption in springtime 2011. During the Asian dust episode, the contribution of Asian dust particle to aerosol absorption coefficient estimated about 45% at 370 nm and about 23% at 520 nm. Especially, black carbon in dust plume contributes about 48% to aerosol light absorption at 520 nm since the airmass are transported from the Gobi and inner Mongolia deserts, and this airmass comes across the northeastern coast of China, near the Shandong Peninsula. In pollution case, the contributions of dust particle and black carbon to aerosol absorption coefficient estimated about 41% and 11% at 370 nm, respectively. However, pollution case shows the highest light absorption of 48% for brown carbon at 370 nm, which indicates the significantly high mass concentration of organic carbon ($6.3{\pm}2.2{\mu}g\;m^{-3}$) in pollution plume can contribute to the increase of light absorption at near-UV spectral region.

Comparative Study of Exposure Assessment of Dust in Building Materials Enterprises Using ART and Monte Carlo

  • Wei Jiang;Zonghao Wu;Mengqi Zhang;Haoguang Zhang
    • Safety and Health at Work
    • /
    • 제15권1호
    • /
    • pp.33-41
    • /
    • 2024
  • Background: Dust generated during the processing of building materials enterprises can pose a serious health risk. The study aimed to compare and analyze the results of ART and the Monte Carlo model for the dust exposure assessment in building materials enterprises, to derive the application scope of the two models. Methods: First, ART and the Monte Carlo model were used to assess the exposure to dust in each of the 15 building materials enterprises. Then, a comparative analysis of the exposure assessment results was conducted. Finally, the model factors were analyzed using correlation analysis and the scope of application of the models was determined. Results: The results show that ART is mainly influenced by four factors, namely, localized controls, segregation, dispersion, surface contamination, and fugitive emissions, and applies to scenarios where the workplace information of the building materials enterprises is specific and the average dust concentration is greater than or equal to 1.5 mg/m3. The Monte Carlo model is mainly influenced by the dust concentration in the workplace of building materials enterprises and is suitable for scenarios where the dust concentration in the workplace of the building materials enterprises is relatively uniform and the average dust concentration is less than or equal to 6mg/m3. Conclusion: ART is most accurate when workplace information is specific and average dust concentration is > 1.5 mg/m3; whereas, The Monte Carlo model is the best when dust concentration is homogeneous and average dust concentration is < 6 mg/m3.

미세액적에 의한 미세먼지 포집 가시화 연구 (A Study on Visualization of Fine Dust Captured by FOG Droplet)

  • 오진호;김현동;이정언;양준환;김경천
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.39-45
    • /
    • 2021
  • An experiment to visualize fine dust captured by FOG droplet is conducted. Coal dust with 23.56 MMD (Mean Median Diameter) and water with 17.02 MMD is used as fine dust and FOG droplet. Long distance microscope and high-speed camera are used to capture the images of micro-scale particles sprinkled by acrylic duct. After measuring and comparing the size of the coal dust and FOG droplet to MMD, process to seize the coal dust with FOG droplet is recorded in 2 conditions: Fixed and Floated coal dust in the floated FOG droplet flow. In both conditions, a coal dust particle is collided and captured by a FOG droplet particle. A FOG droplet particle attached at the surface of the coal dust particle does not break and remains spherical shape due to surface tension. Combined particles are rotated by momentum of the particle and fallen.

실험동물 랫드를 이용한 미세먼지 기도노출에 따른 호흡기계 독성에 대한 마늘의 예방효과 탐색 (Preventive Effect of Garlic Administration on Respiratory Toxicity Induced through Intratracheal Instillation of Fine Dust (PM10) in Rats)

  • 이윤범;김근우;송영민;한영훈;하창수;이지선;김민희;손혜영;이기용;허용;김창열
    • 한국환경보건학회지
    • /
    • 제46권6호
    • /
    • pp.667-675
    • /
    • 2020
  • Objectives: Exposure to fine dust (PM10) could contribute to the occurrence of cardiovascular disease or respiratory abnormalities. Since garlic is known to possess an anti-oxidative stress effect, the present study was performed to evaluate the effect of garlic intake on fine dust-mediated pulmonary toxicity. Methods: Rats were intratracheally instilled with fine dust at 15 mg/kg body weight (BW)/day for five days following five-day intragastric intubation of garlic at 0.7 or 1.4 g/kgBW/day, or 13.1 mg/kgBW/day S-allyl-cysteine (SAC) as a reference component in garlic. Blood and bronchoalveolar lavage fluid (BALF) were collected. Results: Deposit of fine dust was visually and histopathologically observed in the lungs. Body weight gain during the instillation period was significantly lowered in all the groups instilled with fine dust. Neutrophil numbers in blood were significantly elevated in the fine dust alone group, but this alteration was diminished in the groups administered with garlic. Levels of serum glutathione were lower in the rats instilled with fine dust alone, and this decrease in the glutathione level seems dose-dependently compensated among the groups administered with garlic. Similar findings were observed in the BALF with statistical significance. Typical pulmonary histopathological observation related with inflammation was demonstrated in the lungs of the rats exposed to fine dust alone, whereas such histopathologic findings were not improved in the groups administered with garlic. Conclusion: The present study suggests that garlic intake could alleviate fine dust-mediated pulmonary or systemic toxicities. Further investigation is necessary to delineate the mechanism of garlic-mediated effects on pulmonary function.

아토피 아동 가정내 집먼지 진드기 농도와 환경요인: 환자 대조군 연구 (House Dust Mites and Associated Environmental Factors in Homes of Atopic Children: a Case-Control Study)

  • 김성호;박동진;변혜정;이현수;오인보;심창선;김양호;윤충식
    • 한국환경보건학회지
    • /
    • 제38권3호
    • /
    • pp.204-212
    • /
    • 2012
  • Objectives: The purpose of this study was to determine house dust mite concentrations in living rooms and bedding materials in atopic case-control groups. Methods: Fifty four homes with children suffering atopic diseases as cases and fifty one homes without atopic diseases as controls were selected after diagnosis at three elementary schools in Ulsan City. Dust samples were collected from the living rooms and bedding materials in each home during summer and winter with a vacuum cleaner and analyzed for house dust mites using enzyme-linked immunosorbent assay (ELISA). Environmental factors and family history were surveyed during sampling. Results: Both species of house dust mite Dermatophagoides farina (Der f 1) and Dermatophagoides pteronyssinus (Der p 1) were found in all homes. Derf1 concentrations were much higher than Der P1 concentrations, both in atopic homes (1518.9 vs. 27.0 ng/g. dust, respectively) and non-atopic homes (810.8 vs. 44.3 ng/g. dust, respectively). Der f 1 concentrations were significantly higher in the atopic group than in the non-atopic group (atopic: 1518.9 ng/g.dust, non-atopic: 810.8 ng/g.dust, p = 0.035). However, total house dust mite Der p 1 concentrations were significantly higher in the non-atopic group than in the atopic group (atopic: 27.0 ng/g.dust, non-atopic: 44.3 ng/g.dust, p = 0.035). Multiple regression implied that mothers with family history of atopic diseases (OR = 4.79, 95% CI = 1.81-12.69), Der f 1 concentrations (OR = 1.74, 95% CI = 1.07-2.81), and air freshener use (OR = 4.60, 95% CI = 1.72-12.34) had significant associations with atopic children. Conclusion: House dust mite Der f 1 concentrations were associated with atopic children. This study suggests that parents should reduce house dust mite Der f 1 concentrations through environmental controls.

Dynamics of pre-shift and post-shift lung function parameters among wood workers in Ghana

  • John Ekman;Philip Quartey;Abdala Mumuni Ussif;Niklas Ricklund;Daniel Lawer Egbenya;Gideon Akuamoah Wiafe;Korantema Mawuena Tsegah;Akua Karikari;Hakan Lofstedt;Francis Tanam Djankpa
    • Annals of Occupational and Environmental Medicine
    • /
    • 제35권
    • /
    • pp.39.1-39.14
    • /
    • 2023
  • Background: Diseases affecting the lungs and airways contribute significantly to the global burden of disease. The problem in low- and middle-income countries appears to be exacerbated by a shift in global manufacturing base to these countries and inadequate enforcement of environmental and safety standards. In Ghana, the potential adverse effects on respiratory function associated with occupational wood dust exposure have not been thoroughly investigated. Methods: Sixty-four male sawmill workers and 64 non-woodworkers participated in this study. The concentration of wood dust exposure, prevalence and likelihood of association of respiratory symptoms with wood dust exposure and changes in pulmonary function test (PFT) parameters in association with wood dust exposure were determined from dust concentration measurements, symptoms questionnaire and lung function test parameters. Results: Sawmill workers were exposed to inhalable dust concentration of 3.09 ± 0.04 mg/m3 but did not use respirators and engaged in personal grooming habits that are known to increase dust inhalation. The sawmill operators also showed higher prevalence and likelihoods of association with respiratory symptoms, a significant cross-shift decline in some PFT parameters and a shift towards a restrictive pattern of lung dysfunction by end of daily shift. The before-shift PFT parameters of woodworkers were comparable to those of non-woodworkers, indicating a lack of chronic effects of wood dust exposure. Conclusions: Wood dust exposure at the study site was associated with acute respiratory symptoms and acute changes in some PFT parameters. This calls for institution and enforcement of workplace and environmental safety policies to minimise exposure at sawmill operating sites, and ultimately, decrease the burden of respiratory diseases.

토양 분진발생장치의 개발과 평가 (Development and Evaluation of a Dust Generator Using Soil Samples)

  • 이지연;이기영
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.383-390
    • /
    • 2010
  • Exposure to fugitive dust can contribute to several respiratory health problems, and proper sampling of fugitive dust is necessary to assess exposure. However, field sampling of soil dust encounters problems from spatial and temporal differences in soil properties, field operations, and meteorological conditions. To minimize these problems, we designed a dust generator that simulates dust generation from soil. The dust generator consisted of a rotating chamber where soil samples were loaded and tumbled, and a settling chamber, where airborne soil dust samples were collected. As standard operating conditions, we decided on 2 g soil mass, 10 min sampling time, and 20 rpm rotating speed, with a flow rate of 30 l/min, based on three common soil textures of loam, sandy loam and silt loam. To evaluate optimal operating conditions, we used mixtures of Joomoonjin silica sand and clay. Although the average $PM_{10}$ concentration of Joomoonjin silica sand was low, dust concentrations were increased by an increased content of clay. The dust concentrations were consistent across repeated experiments, and showed similar concentration profiles during the sampling time with mixtures of clay and sand (coefficient of variation was $13.6{\pm}w;7.1%$). The results demonstrated that these standard operating conditions were suitable for the dust generator, which can be used to investigate variations in soil properties that affect dust production and potential potency of fugitive dust exposure.

Study on prestressed concrete beams and poles with cement replaced by steel dust

  • Sujitha Magdalene, P;Harishankar, S
    • Advances in concrete construction
    • /
    • 제5권4호
    • /
    • pp.391-405
    • /
    • 2017
  • Cement acts as the most important component of concrete as it binds and holds the concrete together. But it is one of the major $CO_2$ emitters all over the world, during manufacturing (900 kg of $CO_2$ per 1000 kg). Some of the modern construction methods aim at reducing the amount of usage of cement and came out with numerous solutions for replacement of the same. One such supplement in current trend is the Steel dust or the Electric Arc Furnace Dust (EAFD), which is a waste product from the electric arc furnace when the scrap metal is melted. When the concrete containing steel dust is exposed to atmosphere, the environmental oxygen and moisture play role to form rust and ultimately the member becomes harder. As Cement is the binder of conventional concrete, only certain percentage of the same could be replaced by the new material, steel dust. Tests were conducted for the 28 days cube strength of M45 grade (suitable for prestressing) concrete which has 0%, 10%, 20%, 30%, 40% and 50% steel dust instead cement. From the test, the optimum percentage replacement of steel dust was obtained, for which the beams and overhead poles were cast, prestressed and tested for the failure load and deflections. A conventional concrete beam and overhead pole were also cast, prestressed and tested to compare the results with those of the beam and pole that contained steel dust. The load vs. deflection plot and other results from the test is also discussed.