• 제목/요약/키워드: School Building

검색결과 4,247건 처리시간 0.025초

녹색건축 인증기준 개선에 관한 연구 -학교시설 용도를 중심으로- (A Research on the Improvement of G-SEED Certification Standards - Focused on School Facility -)

  • 맹준호;김성중
    • 교육녹색환경연구
    • /
    • 제13권1호
    • /
    • pp.41-49
    • /
    • 2014
  • Currently G-SEED certification standards was in an effort to building energy-saving and carbon emissions reduction. In this study, focusing on school facilities to suggest an alternative improve green building certification standards through data analysis and conduct an expert Delphi survey. In this study, evaluation of the existing areas of green building certification 7-5 suggest that one out. There are five proposed areas of ecology, health, function, energy and resources. Further it can add areas of economics and $LCCO_2$. Through the assessment items of foreign certification standards evaluated to the feasibility of introducing in Korea. Furthermore taking into account the characteristics of each class, kindergarten, elementary, primary, middle and high schools, College or University were broken down by purpose.

인공지반이 건물 열환경에 미치는 효과에 관한 연구 (The Effect of the Artificial Ground on Building Thermal Environment)

  • 황효근;임종연;류민경;송두삼
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.170-175
    • /
    • 2009
  • Apartment housing block has been spreaded according to rapid economic development and urbanization in Korea. A parking lot is located at underground, artificial ground is inevitably created in apartment housing block. Artificial ground creates different thermal environment compared to natural ground, because the composition and coverage of artificial ground are diverse. In this study, the effect of the artificial ground on building thermal environment will be disscussed by simulation. Considering the result of simulation, surface albedo is more important for building energy performance. A purpose of this study is to examine how the characteristic of surface effect to thermal environment, and to develop design method for sustainable outdoor space.

  • PDF

학교 건물에서 외부 차양 장치 유형에 따른 일반교실 내 빛환경 특성에 관한 연구 (A Study on the Characteristics of Daylighting Environment in Classroom of an School Building Due to the External Shading Devices)

  • 임재한;정진주;이지영
    • 교육시설
    • /
    • 제15권2호
    • /
    • pp.4-15
    • /
    • 2008
  • The purpose of this study was to evaluate the characteristics of daylighting environment in classroom of an school building due to the external shading devices such as fixed louvers, light shelves and exterior venetian blinds. In this study, we have made a field research with regard to the facade design in classroom of an school building. And we have made a classification of external shading devices considering the design parameters. Finally, through RADIANCE simulation, we have calculated the spatial distribution of illuminance, uniformity ratio of illuminance and daylight factors. The results of this study will provide the building designer with the basic daylighting performance data at early design stages.

목질마루바닥재와 벽체용 재료를 이용한 평판열류계법과 MTPS (Modified Transient Plane Source)법의 열전도율 상관관계 분석 (Correlation Analysis of the Thermal Conductivity Heat Flow Meter and MTPS (Modified Transient Plane Source) Method Using Wood Flooring and Wall Materials)

  • 차정훈;서정기;김수민
    • 한국가구학회지
    • /
    • 제22권2호
    • /
    • pp.118-125
    • /
    • 2011
  • These days global warming is the most important problem and the most important factor is high emission of carbon dioxide. The 23% of carbon dioxide emission for building construction must be reduced. Thermal conductivity is the most basic factor that can decrease the energy consumption especially insulation. Therefore, an accurate and continuous thermal conductivity measurement can be a way to save energy. In this paper, there are methods about how to investigate thermal conductivity measurements and comparing two methods which are the Heat Flow Meter 436 and TCi.

  • PDF

공공건축물의 신재생에너지 적용분석 및 건물에너지 분담률 분석 (An Application Analysis of Renewable Energy for Public Building and an Analysis of Building Energy Substitution Rate)

  • 강수현;유시완;황정하;조영흠
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.348-353
    • /
    • 2011
  • Recently the renewable energy has been used widely and the importance of renewable sources is bigger than before. So the government enforced a law to the public buildings to install the renewable energy facilities. The capacity of facilities is 5% of total construction cost until April 13, 2011. Since then, the government changed the law from 5% of total construction cost to 10% of predicted energy usage because of the practical use of the renewable energy facilities. So, in this study, the comparative analysis is conducted according to the law to the building installed PV system through the EnergyPlus simulation.

  • PDF

Building Information Modeling(BIM)을 적용한 초등학교 설계에 관한 연구 (A Study on Architectural Design of Elementary School Using Building Information Modeling(BIM))

  • 조재근;전한종
    • 교육시설
    • /
    • 제14권3호
    • /
    • pp.5-16
    • /
    • 2007
  • The main purpose of this study is to find out the strengths and weaknesses of the application of BIM to the educational facilities. To do so, we model Sanggye elementary school project using BIM, and consider other efficient methods for the lack of the information caused by the traditional blueprint. In addition, we try to lay the groundwork for expanding the application of BIM during the life cycle of an educational facility through researching a system to set up an accurate building information.

사무소건축 리모델링에서의 전과정 평가에 관한 연구 - 전기 부분을 중심으로 - (A study of LCA(Life Cycle Assessment) to a office building remodeling - Focused on Electrical Equipment -)

  • 이선동;유호천
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.85-92
    • /
    • 2004
  • Environmental issues become one of today's central concerns due to draining natural resources and environmental pollution. Architecture is given a great deal of weight on the evoking environmental pollution. In this point of view, polluting factors in architectural planning and construction were predicted in advance and alternative plans were studied, In investigation of alternative plans, both environmental pollution and economical efficiency of various alternatives were considered. A office building was analyzed for energy consumption and construction environmental load by appling LCA. Applying LCA to a office building includes a total amount of materials and energy consumption, environmental impacts and economical efficiency evaluation. In present study, LCA applied to electrical part of a office building and economical efficiency evaluation was considered.

Innovative Nuclear Power Plant Building Arrangement in Consideration of Decommissioning

  • Choi, Won-Jun;Roh, Myung-Sub;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.525-533
    • /
    • 2017
  • A new concept termed the Innovative Nuclear Power Plant Building Arrangement (INBA) strategy is a new nuclear power plant building arrangement method which encompasses upfront consideration of more efficient decommissioning. Although existing decommissioning strategies such as immediate dismantling and differed dismantling has the advantage of either early site restoration or radioactive decommissioning waste reduction, the INBA strategy has the advantages of both strategies. In this research paper, the concept and the implementation method of the INBA strategy will be described. Two primary benefits will be further described: (1) early site restoration; and (2) radioactive waste reduction. Several other potential benefits will also be identified. For the estimation of economic benefit, the INBA strategy, with two primary benefits, will be compared with the immediate dismantling strategy. The effect of a short life cycle nuclear power plant in combination with the INBA strategy will be reviewed. Finally, some of the major impediments to the realization of this strategy will be discussed.

Environmental assessment of a BIPV system

  • Demetrios N. Papadopoulos;Constantinos N. Antonopoulos;Vagelis G. Papadakis
    • Advances in Energy Research
    • /
    • 제8권1호
    • /
    • pp.1-19
    • /
    • 2022
  • The application of Photovoltaic (PV) power in the building sector, is expanding as part of the ongoing energy transition into renewables. The article addresses the question of sustainability of energy generated from PVs through an environmental assessment of a building-integrated PV system (BIPV) connected to the grid through net metering. Employing retrospective life cycle analysis (LCA), with the CCaLC2 software and ecoinvent data, the article shows that the carrying structure and other balance of system (BOS) components are responsible for a three times higher energy payback time than the literature average. However, total environmental impact can be lowered through reuse or reinstallation of PVs on the same building structure after the 30-year interval. Further ways to improve environmental efficiency include identifying the most polluting materials for each LCA parameter. The results of this study are of interest to researchers and producers of PVs and organizations investing and promoting decentralized power production through PVs.

Component Analysis of Thermally Activated Building System in Residential Buildings

  • Chung, Woong June;Lee, Yu Ji;Yoo, Mi Hye;Park, Sang Hoon;Yeo, Myoung Souk;Kim, Kwang Woo
    • Architectural research
    • /
    • 제16권4호
    • /
    • pp.203-210
    • /
    • 2014
  • The packaged terminal air conditioner, the typical cooling system for the residential buildings, consumes a large amount of electricity in a short period time during peak hours. In order to reduce the peak load and conserve the electricity, the thermally activated building system can be used as a secondary system to handle the partial cooling load. However, the thermally activated building system may cause condensation and under-cooling. Thus, design of both systems should be performed with careful investigation in characteristics of both systems to amplify the advantages. Since the thermally activated building system has the time-delay effect which may cause under-cooling, the system is designed to handle the base load of the building. Hence, simple simulation with EnergyPlus was performed to observe the characteristics of cooling load in residential buildings. Once the possible range of the load handling ratio of the thermally activated building system was decided, characteristics of system was analyzed in terms of hardware component and operation parameters. The hardware components were analyzed in plant and system aspects and the operation parameter was evaluated in the thermal comfort aspect. As the load handling ratio increased, the thermal comfort increased due to the lower radiant mean temperatures. Within the range of thermal comfort, the several adjustments were made in setpoint temperature and electricity consumptions of difference cases were observed to decide which components and parameters were important for designing the systems.