• 제목/요약/키워드: Scenario-based test

검색결과 304건 처리시간 0.024초

An Input Transformation with MFCCs and CNN Learning Based Robust Bearing Fault Diagnosis Method for Various Working Conditions (MFCCs를 이용한 입력 변환과 CNN 학습에 기반한 운영 환경 변화에 강건한 베어링 결함 진단 방법)

  • Seo, Yangjin
    • KIPS Transactions on Software and Data Engineering
    • /
    • 제11권4호
    • /
    • pp.179-188
    • /
    • 2022
  • There have been many successful researches on a bearing fault diagnosis based on Deep Learning, but there is still a critical issue of the data distribution difference between training data and test data from their different working conditions causing performance degradation in applying those methods to the machines in the field. As a solution, a data adaptation method has been proposed and showed a good result, but each and every approach is strictly limited to a specific applying scenario or presupposition, which makes it still difficult to be used as a real-world application. Therefore, in this study, we have proposed a method that, using a data transformation with MFCCs and a simple CNN architecture, can perform a robust diagnosis on a target domain data without an additional learning or tuning on the model generated from a source domain data and conducted an experiment and analysis on the proposed method with the CWRU bearing dataset, which is one of the representative datasests for bearing fault diagnosis. The experimental results showed that our method achieved an equal performance to those of transfer learning based methods and a better performance by at least 15% compared to that of an input transformation based baseline method.

Development of Collision Scenario-Based Evaluation System for the Cognitive Performance of Marine Officers (충돌시나리오 기반의 항해사 인지능력 평가시스템 개발)

  • Kim, Hong-Tae;Barentt, Mike;Yang, Won-Jae
    • Journal of Navigation and Port Research
    • /
    • 제31권8호
    • /
    • pp.629-635
    • /
    • 2007
  • Reduced crew performance is frequently cited as a major causal factor in maritime accident causation. Although considerable research has been conducted on the hours of work undertaken by seafarers through interviews and the analysis of records, experimental studies to observe the effects of factors such as high workload, shift patterns, stress, sleep deprivation and disturbance on the cognitive performance of mariners have been limited. Other safety-critical transport industries, such as aviation and rail, have developed fatigue management tools to help manage the work patterns of their operators. Such a tool for mariners would assist shipboard crew, marine pilots and shore management in planning and improving work schedules. The overall aim of this paper is to determine a fatigue factor, which can be applied to human performance data, as part of a software program that calculates total cognitive performance. This program enables us to establish the levels of cognitive performance of a group of marine pilots to test a decision-making task based on radar information. This paper addresses one of the factors that may contribute to the determination of various fatigue factors: the effect of different work patterns on the cognitive performance of a marine pilot.

Designing Effective Virtual Training: A Case Study in Maritime Safety

  • Jung, Jinki;Kim, Hongtae
    • Journal of the Ergonomics Society of Korea
    • /
    • 제36권5호
    • /
    • pp.385-394
    • /
    • 2017
  • Objective: The aim of this study is to investigate how to design effective virtual reality-based training (i.e., virtual training) in maritime safety and to present methods for enhancing interface fidelity by employing immersive interaction and 3D user interface (UI) design. Background: Emerging virtual reality technologies and hardware enable to provide immersive experiences to individuals. There is also a theory that the improvement of fidelity can improve the training efficiency. Such a sense of immersion can be utilized as an element for realizing effective training in the virtual space. Method: As an immersive interaction, we implemented gesture-based interaction using leap motion and Myo armband type sensors. Hand gestures captured from both sensors are used to interact with the virtual appliance in the scenario. The proposed 3D UI design is employed to visualize appropriate information for tasks in training. Results: A usability study to evaluate the effectiveness of the proposed method has been carried out. As a result, the usability test of satisfaction, intuitiveness of UI, ease of procedure learning, and equipment understanding showed that virtual training-based exercise was superior to existing training. These improvements were also independent of the type of input devices for virtual training. Conclusion: We have shown through experiments that the proposed interaction design results are more efficient interactions than the existing training method. The improvement of interface fidelity through intuitive and immediate feedback on the input device and the training information improve user satisfaction with the system, as well as training efficiency. Application: Design methods for an effective virtual training system can be applied to other areas by which trainees are required to do sophisticated job with their hands.

A Context Recognition System for Various Food Intake using Mobile and Wearable Sensor Data (모바일 및 웨어러블 센서 데이터를 이용한 다양한 식사상황 인식 시스템)

  • Kim, Kee-Hoon;Cho, Sung-Bae
    • Journal of KIISE
    • /
    • 제43권5호
    • /
    • pp.531-540
    • /
    • 2016
  • Development of various sensors attached to mobile and wearable devices has led to increasing recognition of current context-based service to the user. In this study, we proposed a probabilistic model for recognizing user's food intake context, which can occur in a great variety of contexts. The model uses low-level sensor data from mobile and wrist-wearable devices that can be widely available in daily life. To cope with innate complexity and fuzziness in high-level activities like food intake, a context model represents the relevant contexts systematically based on 4 components of activity theory and 5 W's, and tree-structured Bayesian network recognizes the probabilistic state. To verify the proposed method, we collected 383 minutes of data from 4 people in a week and found that the proposed method outperforms the conventional machine learning methods in accuracy (93.21%). Also, we conducted a scenario-based test and investigated the effect contribution of individual components for recognition.

PLC-Based Smart grid Home Network System Design and Implementation using OPNET Simulation

  • Huh, Jun-Ho;Seo, Kyungryong
    • Journal of Multimedia Information System
    • /
    • 제1권2호
    • /
    • pp.111-118
    • /
    • 2014
  • The Smart grid refers to the technology that enables efficient usage of electric power by collecting information concerning the power usage and power lines grafting information and communications technology to onto power grids. There are Zigbee, PLC or IEEE 802.11 WLAN MAC as a core technology of the Smart grid, but in this paper, the discussion is focused on the PLC. The PLC is the technology that carries out data communications using power lines and put into practical use in the field of lights or home appliances control recently but PLC-applied communications between electronic devices are rarely seen. For the reason that the PLC uses high-voltage power lines and has a disadvantage of experiencing higher data loss rate caused by the noises produced by going through transformers, the technology is yet to be used in many areas. Nevertheless, the PLC has been studied widely recently in respect that it's the low-cost communication solution for the Smart Metering [1]. Moreover, this technology is emerging as a novel data communication method and discussed as an important technology lately due to the developments of the Smart grid systems and Internet of things (IoT). Thus, in this paper, the results obtained from designing and performing implementation scenario for the PLC-based Smart grid home network system were compared and analyzed with that of IEEE 802.11 WLAN MAC (the foundation technology at Jeju Smart grid Test bed)-based Smart grid home network. Thus, in this paper, OPNET 14.5 PL8, OSI 7 layer, PLC router nodes and PLC nodes had been used for the designing and implementation simulations of both systems. Additionally, QoS was not considered in order to guarantee that all the traffics would not have the same processing priority.

  • PDF

Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

  • Han, Yang;Luo, Mingyu;Chen, Changqing;Jiang, Aiting;Zhao, Xin;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1904-1917
    • /
    • 2016
  • The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of phase-locked loops (PLLs). This is of vital significance for the grid-integration and stable operation of power electronic converters to electric power systems. However, the open-loop bandwidth is drastically reduced after incorporating a MAF into the PLL structure, which makes the dynamic response sluggish. To overcome this shortcoming, some new techniques have recently been proposed to improve the transient response of MAF-based PLLs. In this paper, a comprehensive performance comparison of advanced MAF-based PLL algorithms is presented. This comparison includes HPLL, MPLC-PLL, QT1-PLL, and DMAF-PLL. Various disturbances, such as grid voltage sag, voltage flicker, harmonics distortion, phase-angle and frequency jumps, DC offsets and noise, are considered to experimentally test the dynamic performances of these PLL algorithms. Finally, an improved positive sequence extraction method for a HPLL under the frequency jumps scenario is presented to compensate for the steady-state error caused by non-frequency adaptive DSC, and a satisfactory performance has been achieved.

A Study on the Improvement of Outpatient Process Using Simulation (시뮬레이션을 이용한 외래프로세스 개선방안에 관한 연구)

  • Choi, Hyun-Sook;Ji, Eun Hee;Kang, Sung-Hong
    • Journal of Digital Convergence
    • /
    • 제12권8호
    • /
    • pp.377-387
    • /
    • 2014
  • The purpose of this study is to suggest improvement ways of outpatient process via a simulation model and to improve operational efficiency. Three experimentation scenarios were implemented into the simulation model to determine which proposed scenario provides better improvement in terms of the following performance measures: LOS(Length of Stay), patient waiting time, patient travel time, and staff utilization. The hospital medical data collection and statistical tools used to analyze the process mining tools. And the PIOS simulation tool was used and the validity of the model was verified by using t-test. The simulation results demonstrated that oupatient process of center type is most efficient. Simulation approach is a powerful technique that supports efficient decision-making compared to traditional healthcare management approach based on past experience, feelings, and intuition. Therefore, the proposed experimentation model has wide applicability in healthcare systems.

Implementation and design of Linux IPv6 Protocol Stack on GSM Phone (GSM Phone 상에서 Linux IPv6 프로토콜 스택 설계 및 구현)

  • Lee, Sang-Woo;Lim, Dong-Hwa;Han, Bosco;Rho, Sun-Ok
    • Journal of KIISE:Information Networking
    • /
    • 제34권1호
    • /
    • pp.16-26
    • /
    • 2007
  • It is well known that, in the near future, the lifetime of the IPv4 address space will be limited and available 32-bit IP network addresses will not be left my more. In order to solve such IPv4 address space problem in an effective way, the transition to the new version using IPv6 architecture is inevitably required. This paper presents the design and implementation of IPv4/IPv6 dual stack at the GSM Phone based on Linux Kernel 2.4 IPv6 Protocol Stack. It designs appropriately in GSM Phone environment and it is tested by a network of Linux IPv4/IPv6 dual stack on PPP. The test was processed with a test scenario and it was found that the results were successful.

The Development and Usability Testing of the Smart Home for Wheelchair Users - Focus on the Activities of Daily Living at Home - (휠체어 사용 장애인을 위한 스마트홈 구축 및 사용성평가 - 주거 환경 내 일상생활활동을 중심으로 -)

  • Lim, Myungjoon;Pyo, Kyung-Sun;Lee, KuemJu;Park, Jiyoung;Choi, Hyun;Kweon, Hyosun
    • Journal of the HCI Society of Korea
    • /
    • 제11권2호
    • /
    • pp.5-14
    • /
    • 2016
  • Wheelchair users found difficulties in living independently in their houses due to the lack of accessibility. The state of the art smart home technology may enable wheelchair users to live independently. In this study, we built a smart home, and tested its usability with three community dwelling wheelchair users. Three evaluation methods such as scenario-based test, K-IADL(Korea instrumental activity of daily living) test, and in-depth interview were used. All three users responded positively for using the smart home. Through this study, we also found several necessary amendments in building smart homes for wheelchair users.

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (고온화재조건 콘크리트 라이닝의 하중비에 따른 폭렬영향성 및 화재손상특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Ahn, Chan-Sol;Kwon, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • 제24권3호
    • /
    • pp.145-151
    • /
    • 2010
  • The fire in tunnel, when failed to extinguish at early stage, tends to easily develop to high temperature and spread to entire area of the tunnel because of considerable level of fire load and smoke control facility within the tunnel, resulting in severe damage to the people and tunnel structure. This study was intended to carry out the fire test with MHC fire curve, a scenario, which has the most rapid fire rise, on assumption of load ratio of 1, 20, 40, 60 and 70%, so as to identify the thermal characteristics of the concrete against spalling and the range of fire damage. The specimen was small scale sample as defined by EFNARC and the mixing ratio was based on 24 MPa, which is considered to be the normal strength. As a result of test, 16mm spalling was occurred on the lining under the non-load condition, while no spalling was occurred with 20% and 40% of load ratio. In case of 60% of load ratio, 24 mm of spalling was occurred and it failed in 10 minutes after heating in case of 70% load condition.