• 제목/요약/키워드: Scattered radiation

검색결과 232건 처리시간 0.041초

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

  • Ayuthaya, Isra Israngkul Na;Suriyapee, Sivalee;Pengvanich, Phongpheath
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.147-154
    • /
    • 2015
  • The scatter photons and photoneutrons from high energy photon beams (more than 10 MV) will increase the undesired dose to the patient and the staff working in linear accelerator room. This undesired dose which is found at out-of-field area can increase the probability of secondary malignancy. The purpose of this study is to determine the equivalent dose of scatter photons and neutrons generated by 3 different treatment techniques: 3D-conformal, intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). The measurement was performed using two types of the optically stimulation luminescence detectors (OSL and OSLN) in the Alderson Rando phantom that was irradiated by 3 different treatment techniques following the actual prostate cancer treatment plans. The scatter photon and neutron equivalent dose were compared among the 3 treatments techniques at the surface in the out-of-field area and the critical organs. Maximum equivalent dose of scatter photons and neutrons was found when using the IMRT technique. The scatter neutrons showed average equivalent doses of 0.26, 0.63 and $0.31mSv{\cdot}Gy^{-1}$ at abdominal surface region which was 20 cm from isocenter for 3D, IMRT and VMAT, respectively. The scattered photons equivalent doses were 6.94, 10.17 and $6.56mSv{\cdot}Gy^{-1}$ for 3D, IMRT and VMAT, respectively. For the 5 organ dose measurements, the scattered neutron and photon equivalent doses in out of field from the IMRT plan were highest. The result revealed that the scatter equivalent doses for neutron and photon were higher for IMRT. So the suitable treatment techniques should be selected to benefit the patient and the treatment room staff.

유방암의 방사선 절선조사에 의한 선량분포 (Dobe Contamination by Tangential Irradiation of Breast Cancer)

  • 이종걸;이병준;이호수;이병제
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.67-70
    • /
    • 1994
  • The use of primary breast irraditation with advantage of improved cosmesis in breast cancer may be the potential risks of radiation for a change in the number of normal breast cancers and lung fibrosis. The magnitude of the scattered dose for a variety of radiation treatment techniques from patient of breast cancer and phantom was measured by adequate dosimeters. We can reduce the dose of the normal breast to treated with radiation by understanding the factors contributing to the unwanted dose and by determining ways to decrease this dose.

  • PDF

2.5 MeV 이하 단색 중성자 표준장에 대한 중성자 실험실내의 산란 중성자 분포 전산모사 (MCNPX Simulation of Scattered Neutron Distribution in Experimental Room for the Neutron Reference Field of Monoenergetic Neutron below 2.5 MeV)

  • 박중헌;김기동
    • Journal of Radiation Protection and Research
    • /
    • 제36권2호
    • /
    • pp.59-63
    • /
    • 2011
  • 가속기 기반 중성자 표준장은 검출기 및 도시메터 교정, 핵자료 생산, 동위원소 생산등 에 필수적으로 필요한 기반 장비이다. 가속기 기반 중성자 표준장 실험실을 설계하는데 있어서 원하는 에너지의 직접적인 중성자 이외에 산란되어서 입사하는 산란 중성자를 줄이는 것은 매우 중요하다. 따라서 그러한 조건을 얻어내기 위하여 다양한 조건을 가정하여 MCNPX 모사계산을 수행하였다. 우선은 기존의 실험실 조건에서 양성자 운동방향인 0도 방향에 있는 중성자 Flux 측정용 공기로 이루어진 가상의 Chamber에 직접 입사하는 중성자 flux와 벽이나 바닥에 충돌을 한 후에 입사하는 간접적인 산란 중성자 flux를 각각 계산하였다. 그 결과 충돌 한 후에 0도 방향의 Chamber에 입사하는 산란 중성자 flux 중에 바닥에 충돌을 한 후 0도 방향의 Chamber로 입사하는 산란 중성자 flux가 가장 많다는 것을 알 수 있었다. 따라서 바닥의 콘크리트만을 없앴을 때와 콘크리트를 제거하고 땅을 1m 정도 파내려갔을 때를 가정하여 재계산을 하였고 그 결과 콘크리트를 없애고 땅을 1m 정도 파면 바닥에 충돌하고 Chamber로 들어오는 산란 중성자 flux가 다른 곳에 충돌하고 들어오는 것보다 낮아지는 정도까지 줄어드는 것을 알 수 있었다.

방사선 치료 시 산란선 및 누설선에 의한 표면선량 분포에 관한 연구 (A Study on the Surface Dose Distribution by Scattered and Leakage Radiation in Radiation Therapy)

  • 강종수;정동경;김용민
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.351-357
    • /
    • 2018
  • 방사선 치료 시 환자는 부득이하게 산란선과 누설선에 의한 2차 방사선 피폭을 받게 된다. 진단용 방사선의 경우 진단참조준위로 환자의 피폭을 줄이기 위한 가이드라인을 제시하고 있지만 치료용 방사선의 경우 2차 방사선에 의한 피폭선량이 상당함에도 불구하고 상한치 설정 시 치료 효과의 저감을 이유로 선량을 제한하지 않고 있다. 이에 본 연구는 선형가속기를 이용한 방사선 치료 시 원거리 조직에서 환자가 받을 수 있는 2차 방사선을 형광유리선량계로 측정하였으며 형광유리선량계의 빌드업 특성에 따른 형광량의 포화도를 측정하였다. 연구 결과 조사야 경계로부터 거리가 멀어질수록 피폭선량은 급격히 줄어들었으며, 두부 1 Gy 조사 시 경부 18.45 mGy, 경부 1 Gy 조사 시 두부 15.55 mGy, 흉부 1 Gy 조사 시 경부 14.26 mGy, 골반 1 Gy 조사 시 흉부 1.14 mGy로 피폭되었다. 형광량의 포화도는 판독시점에 따라 1.8 ~ 4.8% 정도 과대평가 될 수 있음을 확인하였다.

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

유방 X선 검사 시 몬테카를로 시뮬레이션을 이용한 3D 프린팅 차폐재료의 효용성 평가 (Evaluation of the Usefulness of 3D Printed Shielding Materials Using Monte Carlo Simulation during Mammography)

  • 조용인
    • 한국방사선학회논문지
    • /
    • 제14권3호
    • /
    • pp.295-301
    • /
    • 2020
  • 유방암의 조기 검진를 위해 시행되는 유방 X선 검사 시 노출되는 방사선 피폭은 과거 발암의 원인으로도 제기되었으며, 검사 시 발생되는 산란선은 주변 장기에 불필요한 방사선 피폭을 유발할 수 있다. 이에 본 연구에서는 몬테카를로 방법을 통해 일반적인 유방 X선 검사 시 노출되는 인체 장기 선량을 평가하고, 산란선에 의한 방사선 방호를 위한 3D 프린팅 재료 사용 시 장기별 선량감소효과에 대해 산정하였다. 장기별 선량평가 결과, 유방 상하방향 검사 시 검사 반대측 유방은 검사측 유방의 약 22.0%, 눈의 경우 약 58.6%으로 산란선에 의해 높은 영향을 보였다. 이를 방호하기 위한 3D 프린팅 차폐기구 사용 시 검사 반대측 유방의 경우, 1 mm 이상의 두께에서 유효한 선량감소효과를 나타내었다.

X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향 (Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus)

  • 이후민;윤준;김현주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.187-193
    • /
    • 2014
  • 본 연구는 X선 진단장치의 고압정류방식이 그리드 성능을 측정하는 선택도(selectivity)와 대조도 향상능력(contrast improvement ability : K factor)에 미치는 영향을 분석하고자 산란선 함유율을 측정하였다. 정류방식이 서로 다른 X선발생장치를 대상으로 각 장치의 관전압과, 관전류량을 측정하여 출력선량의 정확도를 측정 및 교정한 후 각 장치별 노출조건을 동일하게 설정하고 형광량계를 이용하여 아크릴을 투과한 X선의 산란선 함유율을 측정하였다. Grid 미사용 시 피사체를 투과한 X선의 산란선 함유율 측정 결과는 단상정류방식장치에서 가장 낮은 함유율(34.158%)이 측정되었고, 인버터 정류방식(37.043%)과 삼상24피크 정류방식(37.447%)은 산란선 함유율이 증가하였다. 각 장치들의 산란선 함유율 차이는 최저 0.404%에서 최고 3.289%의 차이를 보였다. 8:1 Gird 사용 시 피사체를 투과한 X선의 산란선 함유율을 측정한 결과는 단상정류방식장치에서 가장 낮은 함유율(18.258%)로 측정되었고, 인버터정류방식(25.502%)과 삼상24피크정류방식에서 산란선 함유율(24.217%)이 증가하였다. 그리드 선택도에 따라 단상정류방식과 정전압(인버터와 삼상24피크)정류방식에서 산란선함유율의 차이는 최저 1.285%에서 최고 7.244%의 차이를 보였다. 통계분석 결과 단상정류방식 및 정전압정류방식에서 대조도 향상계수(K factor)에서도 유의한 차이를 보였다. 결론적으로 그리드 선택도와 대조도 향상계수는 정전압정류방식보다는 단상전파방식에서 모두 증가하여 그리드의 사용으로 선택도 향상과 대조도의 개선효과가 증가함을 알 수 있었다.

산란선 증폭시 차폐체 유무에 따른 선량 분석 (Analyze dosimetry with and without shielding when amplifying scattered rays)

  • 조창호;김정래
    • 문화기술의 융합
    • /
    • 제10권3호
    • /
    • pp.819-825
    • /
    • 2024
  • 진단용방사선발생장치를 사용함에 있어서 선량데이터를 기록하는 이유는 의료진 및 환자의 피폭선량을 기록하고 관리하기 위함이다. 진단용방사선발생장치를 사용함에 있어서 방사선량의 차이를 검증하고 위험성과 차폐체 착용의 유무의 상황에서 피폭선량에 대한 측정과 분석을 통해 사용자의 피폭선량 경감에 대한 인식을 알리고자 하였다. 에스레이튜브와 II튜브에 따라 구분하여 장비를 한국 C-arm 2대, 독일 C-arm 2대장비를 대상으로 각 장비별 선량분석결과 한국 FPD type C-arm 이 가장 높은 선량값이 측정되었고, 독일 I.I type C-arm, 독일 FPD type C-arm, 한국, I.I type C-arm 순서로 피폭선량값이 측정되었다. 차폐체 유무에 따른 피폭선량 분석결과 일반적인 대기상태에 인체팬텀을 놓고 측정결과 산란선에 의해 피폭선량이 약 2배 증가하였으나 차폐체(0.5mm/납앞치마)를 착용하니 약 5배의 피폭선량 감소하는 결과가 나타났다. 피폭선량과 차폐체를 통해 피폭선량의 관리가 중요한 역할을 하며 방사선 피폭을 줄이는 방법을 유추할 수 있다. 또한, 장비마다 출력되는 피폭선량이 다른 특성을 갖고 있음으로 차폐체를 유무를 선별하는데 선량정보로 제공을 할 것으로 기대 한다.

In Vitro에서 광증감제에 의한 광학적 영향에 관한 연구 (A Study on the Optical Influence by Photosensitizer in Vitro)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.182-190
    • /
    • 2005
  • The propagation of light radiation within tissues is an important problem that confronts the dosimetry of therapeutic laser delivery and the development of diagnostic spectroscopy. In the clinical application of photodynamic therapy(PDT) and in photobiology, the photon deposition within a tissue determines the spatial distribution of photochemical reactions. Scattered light is measured as a function of the distance (r) between the axis of the incident beam and the detection spot. Consequently, knowledge of the photosensitizer(Chlorophyll-a) function that characterizes a phantom is important. To obtain the results of scattering coefficients(${\mu}s$) of a turbid material from diffusion described by experimental approach. It was measured the energy fluency of photon radiation at the position of penetration depth. From fluorescence experimental method obtained the analytical expression for the scattered light as the values of $(I\;/I_o)_{wavelength}$ vs the distance between the center of the incident beam and optical fiber in terms of the condition of "in situ spectroscopy(optically thick)" and real time by fluorometric measurements.