• Title/Summary/Keyword: Scattered Data

Search Result 466, Processing Time 0.026 seconds

Dust-scattered FUV halo around Spica

  • Choi, Yeon-Ju;Min, Kyoung-Wook;Park, Jae-Woo;Lim, Tae-Ho;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.73.2-73.2
    • /
    • 2012
  • The far ultraviolet (FUV) wavelength (900-1750A) range includes a wealth of important astrophysical information related to the cooling of hot gas, fluorescent emission from H2 molecules, and starlight scattered off dust particles. Among these, we would like to focus on the scattered emission of the central star by dust with the example of the FUV halo surrounding ${\alpha}$ Vir (Spica). While scattering properties of dust have been studied with the GALEX data, the improved dataset of STSAT-1 revealed many detailed structures of this interesting region. For example, the FUV continuum map obtained from the STSAT-1 observations shows enhanced emission in the southern part of the Spica halo region, where the dust level is also high. In fact, the FUV continuum intensity is seen to have a good correlation with the IRAS 100${\mu}m$ emission data. It is also seen that the scattered spectrum is softer than the original one emitted by the central star, which is attributed to the increase in the dust-scattering albedo with wavelength. We have developed a Monte Carlo code that simulates dust scattering of light including multiple encounters. The code is applied to the present Spica halo region to obtain the scattering properties such as the albedo and the phase function asymmetry factor.

  • PDF

SINGULARITY OF A COEFFICIENT MATRIX

  • Lee, Joon-Sook
    • Communications of the Korean Mathematical Society
    • /
    • v.10 no.4
    • /
    • pp.849-854
    • /
    • 1995
  • The interpolation of scattered data with radial basis functions is knwon for its good fitting. But if data get large, the coefficient matrix becomes almost singular. We introduce different knots and nodes to improve condition number of coefficient matrix. The singulaity of new coefficient matrix is investigated here.

  • PDF

Visualization of Trivariate Scattered Data Interpolation (트라이 베리에이트 산포된 자료 보간의 가시화)

  • Lee, Kun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.2 no.2
    • /
    • pp.11-20
    • /
    • 1996
  • The numerous application of scattered data include the modeling and visualization of physical phenomena. A tetrahedrization is one of pre-processing steps for 4-D surface interpolation. In this paper, various tetrahedrization methods are discussed including, Delaunay, least squares fitting, gradient difference, and jump in normal direction derivatives. This paper discriminates the characteristics of tetrahedrization through visualizing tetrahedral domain. This paper also, provides the tool that can compare and analyze the quality of 4-D space approximation over tetrahedral domain numerically, as well as graphically.

  • PDF

Refinement of DEM boundaries using Point Distribution Criteria in Scattered Data Interpolation

  • KIM Seung-Bum
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.103-106
    • /
    • 2004
  • Extrapolation off the boundaries of scattered data is an intrinsic feature of interpolation. However, extrapolation causes serious problems in stereo-vision and mapping, which has not been investigated carefully. In this paper, we present novel schemes to eliminate the extrapolation effects for the generation of a digital elevation model (DEM). As a first step, we devise point distribution criteria, namely COG (Center of Gravity) and ECI (Empty Center Index), and apply rigorous and robust elimination based on the criteria. Compared with other methods, the proposed schemes are computationally fast and applicable to a wide range of interpolation techniques.

  • PDF

A Study on the Exposure and Free Space Scattered Dose in Radiography (X선 촬영시 피폭선량 및 실내공간선량에 관한 연구)

  • Ahn, Bong-Seon;Lee, Kyu-Eun;Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.26-30
    • /
    • 1998
  • We tried to study in order to furnish the data for medical exposure dose and scattered ray in radiography. As the tables(from 1 to 3) show, we can presume, by means of a concrete numerical value, the amount of results affected by patient radiation exposure dose and somatic effect in radiography. However, there are many difficulties in the difference of exposure factor in each hospital, the accuracy of measuring by tracebility, shortage of exposure dose data especially in the area of children, and portable radiography, etc. In the radiation examination, it is considered if the gained benefit to the patient due to radiation is more than the risk of radiation, then the medical exposure is thought to be justified. Therefore, the radiotechnologists should continually make an effort to develop and study new techniques so as to reduce patient exposure dose.

  • PDF

Restoration of Chest X-ray by Kalman Filter

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.5
    • /
    • pp.581-585
    • /
    • 2010
  • A grid was sandwiched between two cascaded imaging plates. Using a fan-beam X-ray tube and a single exposure scheme, the two imaging plates, respectively, recorded grid-less and grid type information of the object. Referring to the mathematical model of the Grid-less and grid technique, it was explained that the collected components whereas that of imaging plates with grid was of high together with large scattered components whereas that of imaging plate with grid was of low and suppressed scattered components. Based on this assumption and using a Gaussian convolution kernel representing the effect of scattering, the related data of the imaging plates were simulated by computer. These observed data were then employed in the developed post-processing estimation and restoration (kalman-filter) algorithms and accordingly, the quality of the resultant image was effectively improved.

A Tablet PC-based Monitoring System for Oceanic Applications

  • Lee, Ji Young;Oh, Jin Seok
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.4
    • /
    • pp.253-257
    • /
    • 2013
  • Mobile computers can process large amounts of data at high speeds, and it is feasible and easy to implement a remote monitoring system utilizing mobile computers. Because of their portability and convenience, these computers have been employed in various research areas to develop such monitoring systems. Existing monitoring system is a bit difficult to real time monitoring the scattered offshore facilities. So this paper compensate the existing system by using mobile computers such as a tablet PC-based monitoring system. Also, the scattered offshore facilities can be monitored in real-time through the tablet PC. The developed monitoring system is a fully Internet-based monitoring platform that enables one to monitor and control remote oceanic applications at any time and any place where it is possible to access the Internet. It can be applied to many oceanic applications as well as the unmanned systems and remote monitoring systems on land.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

A Fast Scattered Pilot Synchronization Algorithm for DVB-H receiver modem (DVB-H 수신기 모뎀을 위한 고속 분산 파일럿 동기 알고리즘)

  • Um Jung-Sun;Do Joo-Hyun;Lee Hyun;Choi Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1081-1091
    • /
    • 2005
  • Unlike conventional DVB-T transmission with the streaming method, DVB-H system based on the IPDC(IP Data Casting) method uses Time-slicing scheme to achieve the maximization of portability by reducing the power consumption of a receiver. To enhance the power efficiency of the receiver, Time-slicing scheme controls the receiver operation to perform only for corresponding burst in specific time slot. The additional power saving can also be achieved by reducing the required time for synchronization. In this paper, we propose a fast scattered pilot synchronization algorithm, which detects the pilot pattern of currently received OFDM symbol. The proposed scheme is based on the correlation between the adjacent subcarriers of potential scattered pilot position in two consecutively received OFDM symbols. Therefore, it can reduce the time for the scattered pilot synchronization within two symbols as com-pared with the conventional method used for DVB-T. And the proposed algorithm has better performance than the two schemes proposed by Nokia for DVB-H and the method using correlation with reference signal. Extensive com-puter simulation is performed based on ETSI EN300 744 ETSI and performance results show that the proposed algorithm has more efficient and stable operation than the conventional schemes.

Active damage localization technique based on energy propagation of Lamb waves

  • Wang, Lei;Yuan, F.G.
    • Smart Structures and Systems
    • /
    • v.3 no.2
    • /
    • pp.201-217
    • /
    • 2007
  • An active damage detection technique is introduced to locate damage in an isotropic plate using Lamb waves. This technique uses a time-domain energy model of Lamb waves in plates that the wave amplitude inversely decays with the propagation distance along a ray direction. Accordingly the damage localization is formulated as a least-squares problem to minimize an error function between the model and the measured data. An active sensing system with integrated actuators/sensors is controlled to excite/receive $A_0$ mode of Lamb waves in the plate. Scattered wave signals from the damage can be obtained by subtracting the baseline signal of the undamaged plate from the recorded signal of the damaged plate. In the experimental study, after collecting the scattered wave signals, a discrete wavelet transform (DWT) is employed to extract the first scattered wave pack from the damage, then an iterative method is derived to solve the least-squares problem for locating the damage. Since this method does not rely on time-of-flight but wave energy measurement, it is more robust, reliable, and noise-tolerant. Both numerical and experimental examples are performed to verify the efficiency and accuracy of the method, and the results demonstrate that the estimated damage position stably converges to the targeted damage.