• Title/Summary/Keyword: Scanning

Search Result 14,096, Processing Time 0.039 seconds

Aligning Executive Scanning with Strategic Management : The Stages of Executive Scanning Process in Healthcare Organizations

  • Suh, Won-S.
    • Korea Journal of Hospital Management
    • /
    • v.12 no.2
    • /
    • pp.93-111
    • /
    • 2007
  • The thrust in this paper is to discuss the dimensions of executive scanning process (ESP) that support continuous scanning activities by executives. Executive scanning is especially important for the healthcare organizations in these days since the environment they are faced with is extremely complex and dynamic. While much has been written about ESP, two important aspects have been underemphasized in the past. The first is a link to the strategic management process (SMP) or the issue of strategy-scanning alignment. The second is a feedback loop to verify the quality of information generated through scanning process. This paper discusses the improved ESP by adding these two features.

  • PDF

Distribution Analysis of the Local Critical Temperature and Current Density in YBCO Coated Conductors using Low-temperature Scanning Laser and Hall Probe Microscopy (저온 주사 레이저 및 홀소자 현미경을 이용한 YBCO 초전도 선재의 국소적 임계 온도 및 전류 밀도 분포 분석)

  • Park, S.K.;Cho, B.R.;Park, H.Y.;Ri, H.C.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.28-33
    • /
    • 2011
  • Distribution of the local critical temperature and current density in YBCO coated conductors were analyzed using Low-temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). We prepared YBCO coated conductors of various bridge types to study the spatial distribution of the critical temperature and the current density in single and multi bridges. LTSLHPM system was modified for detailed linescan or two-dimensional scan both scanning laser and scanning Hall probe method simultaneously. We analyzed the local critical temperature of single and multi bridges from series of several linescans of scanning laser microscopy. We also investigated local current density and hysteresis curve of single bridge from experimental results of scanning Hall probe microscopy.

Scanning Determination & Observation Features by Sex shown in the Process of Acquiring Visual Information - With the Object of Subway Station Hall Space - (시각정보획득과정에 나타난 주사판정과 성별 주시특성 - 지하철 홀 공간을 대상으로 -)

  • Kim, Jong-Ha;Choi, Gae-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.115-124
    • /
    • 2014
  • This study has carried out scanning tests in order to figure out the features of scanning search by sex of space users, with the result of which the validity of data has been estimated. In this research, the scanning patterns were set up for verifying the typology of scanning paths and then the reason for determining scanning paths and the validity of estimation method were reviewed. Since the observation features depends on sex, the analysis of visual activities for acquiring any information in a space will reveal the intention and purpose of space users. The findings by analyzing the features of scanning pattern by sex which were found at the determination of scanning patterns can be defined as the followings. First, for estimating the process of space-information search, the movement distance at each point of continuative-observation data from the angle of eye-movement has been extracted, on the ground of which the fixation and movement of eye have been defined for the establishment of scanning-cut characteristics. Second, the scanning times were estimated for the extraction of effective observation data that would be used for comparative analysis, which showed that men had more data (3,398.2/64.4%) than women (2,998.2/55.6%). This enables the acknowledgment that the scanning cut of men was relatively less, which indicates that men will acquire more information on space than women in the process of observing any space. Third, men's scanning times (58.0 times/2.02 seconds) were less than those of women (71.9 times/1.39 seconds) while the scanning time of the former was longer than that of the latter, which shows the feature that it takes longer for men than women in scanning while the scanning times of the former is less than those of the latter. Fourth, the observation features can be determined that the combination of this result with the predominance character by sex for a general viewpoint to be employed indicates that while men employ mixed-scanning for observation activities to acquire space-information spending for longer time, women, by concentrated-scanning, focus on a single point for shorter time or stay at one location for a considerably long time for space-information acquirement.

A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis (모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기)

  • Park, Kyi-Hwan;Choi, Ji-Eun;La, Jong-Pil;Wang, Sem-Yung;Kyoung, Yong-Soo;Kim, Koung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.734-741
    • /
    • 2003
  • This paper addresses the vibration mode shape Measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series from, the analysis of the vibration mode shape techniques for straight line scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a cantilever and plate

The Analysis of Motion Error in Scanning Type XY Stage (스캐닝 방식 XY 스테이지의 운동오차 분석)

  • 황주호;박천홍;이찬홍;김동익;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1380-1383
    • /
    • 2004
  • The scanning type XY stage is frequently used these days as precision positioning system in equipment for semiconductor or display element. It is requested higher velocity and more precise accuracy for higher productivity and measuring performance. The position accuracy of general stage is primarily affected by the geometric errors caused by parasitic motion of stage, misalignments such as perpendicular error, and thermal expansion of structure. In the case of scanning type stage, H type frame is usually used as base stage which is driven by two actuators such as linear motor. In the point view of scanning process, the stage is used in moving motion. Therefore, dynamic variation is added as significant position error source with other parasitic motion error. Because the scanning axis is driven by two actuators with two position detectors, 2 dimensional position errors have different characteristic compared to general tacked type XY stage. In this study 2D position error of scanning stage is analyzed by 1D heterodyne interferometer calibrator, which can measure 1D linear position error, straightness error, yaw error and pitch error, and perpendicular error. The 2D position error is evaluated by diagonal measurement (ISO230-6). The yaw error and perpendicular error are compensated on the base stage of scanning axis. And, the horizontal straightness error is compensated by cross axis compensation. And, dynamic motion error in scanning motion is analyzed.

  • PDF

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.

Analysis of Features to Acquire Observation Information by Sex through Scanning Path Tracing - With the Object of Space in Cafe - (주사경로 추적을 통한 성별 주시정보 획득특성 - 카페 공간을 대상으로 -)

  • Choi, Gae-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.5
    • /
    • pp.76-85
    • /
    • 2014
  • When conscious and unconscious exploring information of space-visitors which is contained in the information acquired in the process of seeing any space is analyzed, it can be found what those visitors pick up as factors in the space for its selection as visual information in order to put it into action. This study, with the object of the space reproduced in three dimensions from the cafe which was visited for conversation, has analyzed the process of acquiring space-information by sex to find out the features of scanning path, findings of which are the followings. First, the rate of scanning type of males was "Combination (50.5%)- Circulation (31.0%) and that of females "Horizontal (32.5%) - Combination (32.1%)", which shows that there was a big difference by sex in the scanning path which took place in the process of observing any space. Second, when the features of continuous observation frequency by sex is looked into, the trends of increased "horizontal" scanning and decreased "Combination" scanning of both showed the same as the frequency of continuous observations increased, while in case of "Circulation" scanning, that of females was found to decrease but that of males showed the aspect of confusion. Third, the 'Combination' scanning of males was found strong at the short observation time with three times of continuous observation frequency defined as "Attention Concentration" while the distinct feature was seen that the scanning type was dispersed to "combination-circulation" as the frequency of continuous observation increased. Females start the information acquirement with "combination-circulation" but in the process of visual appreciation they showed a strong "Horizontal" These scanning features can be defined as those by sex for acquiring space information and therefore are very significant because they are fundamental studies which will enable any customized space-design by sex.

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

Developent of Scanning and Registration Methods Using Tooling Balls (툴링볼을 이용한 측정 및 레지스트레이션 방법 개발)

  • 김용환;윤정호;이관행
    • Korean Journal of Computational Design and Engineering
    • /
    • v.4 no.1
    • /
    • pp.60-68
    • /
    • 1999
  • In reverse engineering (RE) sustems, the quality of the data aquisition process is crucial to the accuracy of the reverse engineered three dimensional computer-aided design (CAD) model. However, these tasks are predominantly done manually, and little work has been done to improve the efficiency of scanning by determining the minimum number of scans and the optimal scanning directions. In this paper, new scanning and registration methods using tooling balls are developed to assist in determining the optimal parameter for these processes. When the object to scanned has no concavity, attaching path of the object and its bounding rectangle are used for optimal scanning and registration. Then minimum number of tooling balls and their positions are calculated automatically. In the case of concave parts, the scanning plan should include a complete scan of the concave area. With the surface normal vector and the scanning direction, the minimum degree of rotating the part can be calculated. But the maximum rotation should be restricted in order to prevent occlusion of the part. Finally tow sample part ar scanned based on the proposed methods and the results are discussed.

  • PDF

Pattern Shape Modulation by Scanning Methods in E-Beam Lithography (전자빔 리소그래피를 이용한 주사기법에 따른 패턴형상 조정)

  • Oh, Se-Kyu;Kim, Seoung-Jae;Kim, Dong-Hwan;Park, Keun;Jang, Dong-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.558-564
    • /
    • 2009
  • To aim at obtaining a correct and fine small pattern by an electron beam lithography several conditions and methods affecting a real pattern shape needs to be investigated. A micro/nano sized pattern shape is sometimes dependent on the scanning method. In this work, four types of scanning methods are implemented and their characteristics are investigated. For a $11\times11um$ pattern, a Zigzag scanning method proves a precise pattern generation. The other ways such as SEM scanning and swirl in-out scanning method result in some distorted pattern shape. It is proved that abrupt change in the pattern generation limits to obtaining a fine and small pattern.

  • PDF