• 제목/요약/키워드: Scanning

검색결과 14,168건 처리시간 0.046초

3D BUILDING RECONSTRUCTION FROM AIRBORNE LASER SCANNING DATA

  • Lee, Jeong-Ho;Han, Soo-Hee;Yu, Ki-Yun;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.587-590
    • /
    • 2007
  • The demand for more accurate and realistic 3D urban models has been increasing more and more. Many studies have been conducted to extract 3D features from remote sensing data such as satellite images, aerial photos, and airborne laser scanning data. In this paper a technique is presented to extract and reconstruct 3D buildings in urban areas using airborne laser scanning data. Firstly all points in a building were divided into some groups by height difference. From segmented laser scanning data of irregularly distributed points we generalized and regularized building boundaries which better approximate the real boundaries. Then the roof points which are subject to the same groups were classified using pre-defined models by least squares fitting. Finally all parameters of the roof surfaces were determined and 3D building models were constructed. Some buildings with complex shapes were selected to test our presented algorithms. The results showed that proposed approach has good potential for reconstructing complex buildings in detail using only airborne laser scanning data.

  • PDF

Correction for Scanning Errors of a CCD Camera Scanner (CCD Camera Scanner의 스캐닝 왜곡 보정기법 연구)

  • 안기원
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제12권2호
    • /
    • pp.173-180
    • /
    • 1994
  • One can see more and more photograrmmetric applications dealing with the extraction of information from images obtained with CCD (Charge Coupled Device) camera scanners. In order for this information to be useful, the scanning errors of scanners must be known through a calibration. Investigation of this study is given to the detailed procedure of the correction for scanning errors created during the scanning of photographs with CCD camera scanner using the three kinds of high resolution reseal plates prepared. The geometric corrected digital images for scanning errors were generated and the accuracy of the resulting new images for each types of plates were checked comparing its image coordinates with there corresponding ground coordinates for the check points.

  • PDF

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • 제25권4호
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.

Design of 2-DoF Scanning Mirror using Electromagnetic force (전자기력을 이용한 2 자유도 스캐닝 미러 설계)

  • Shin, Bu Hyun;Kim, Young-Jin;Oh, Dongho;Lee, Jeong-Woo;Choi, Hyun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.177-178
    • /
    • 2014
  • This work proposes a two-dimensional (2-D) laser scanning mirror actuator with a simple structure composed of one magnet and four coils. The mirror-actuating device generates 2-D scanning motions about two orthogonal axes by combining electromagnetic actuators of the conventional moving-magnet types. The magnet is attached to back side of the mirror placed inside of the moving frame. The four coils is placed on the base frame in a cross shape. We implement a finite element analysis to calculate magnetic flux in the electromagnetic system with the overall size of $20mm(W){\times}20mm(D){\times}13mm(H)$ for the mirror size of $8mm{\times}8mm$. The each moving-magnet type electromagnetic actuator has the motor constant 3.41 mNm/A and the restoring constant 1.75 mNm/rad and the resonance frequency of 58 Hz and the bandwidth of 80 Hz. The proposed compact and simple 2-D scanning mirror predicted advantages of large 2-D angular deflections, wide frequency bandwidth and low manufacturing cost.

  • PDF

A Study on Pancreas Scanning with $Selenium^{75}$-Selenomethionine ($^{75}Se$-Selenomethionine 을 이용(利用)한 췌장주사(膵臟走査)에 관(關)한 연구(硏究))

  • Shin, Hyun-Chan;Toh, Sang-Hee;Ra, Woo-Youn;Suh, Chul-Sung
    • The Korean Journal of Nuclear Medicine
    • /
    • 제2권1호
    • /
    • pp.21-25
    • /
    • 1968
  • Radiographic visualization of the pancreas is a difficult problem, but the direct visualization of the pancreas is possible by the injection of the amino-acid methionine tagged with $selenium^{75}$75 ($Se^{75}$). In order to know the diagnostic value of pancreas scanning, scans were performed on 23 cases using $selenium^{75}$-selenomethionine. These cases were also given egg white, probanthine and morphine. 1. Good visualization of the pancreas scanning was observed on 19 cases, presumably with normal pancreas. 2. A case which showed diffusely decreased uptake on pancreas scanning was proven to have lesions in the bile duct and the gall bladder. 3. Of those two cases which showed localized cold area, one had pancreas cyst and the other one was not explored. 4. A case which showed no visualization of the pancreas was proven to have pancreatic carcinoma. 5. Two cases which showed widened duodenal loop by upper gastro-intestinal series revealed normal pancreas scanning, and no pancreatic disease was found in both cases.

  • PDF

Methods to Measure the Critical Dimension of the Bottoms of Through-Silicon Vias Using White-Light Scanning Interferometry

  • Hyun, Changhong;Kim, Seongryong;Pahk, Heuijae
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.531-537
    • /
    • 2014
  • Through-silicon vias (TSVs) are fine, deep holes fabricated for connecting vertically stacked wafers during three-dimensional packaging of semiconductors. Measurement of the TSV geometry is very important because TSVs that are not manufactured as designed can cause many problems, and measuring the critical dimension (CD) of TSVs becomes more and more important, along with depth measurement. Applying white-light scanning interferometry to TSV measurement, especially the bottom CD measurement, is difficult due to the attenuation of light around the edge of the bottom of the hole when using a low numerical aperture. In this paper we propose and demonstrate four bottom CD measurement methods for TSVs: the cross section method, profile analysis method, tomographic image analysis method, and the two-dimensional Gaussian fitting method. To verify and demonstrate these methods, a practical TSV sample with a high aspect ratio of 11.2 is prepared and tested. The results from the proposed measurement methods using white-light scanning interferometry are compared to results from scanning electron microscope (SEM) measurements. The accuracy is highest for the cross section method, with an error of 3.5%, while a relative repeatability of 3.2% is achieved by the two-dimensional Gaussian fitting method.

Performance Evaluation of Non-contact Atomic Force Microscopy Due to Vibration Characteristics of Cantilever (비접촉 원자간력 현미경의 탐침 외팔보 진동특성에 따른 성능 평가)

  • 박준기;권현규;홍성욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.263-268
    • /
    • 2003
  • This paper presents a result of performance evaluation fur non-contact scanning probe microscopy with respect to the vibration characteristics of cantilevers with tips. One of the current issues of the scanning probe microscopy technology is to increase the measurement speed, which is closely tied with the dynamic characteristics of cantilevers. The primary concern in this research is to investigate the relation between the maximum possible speed of non-contact scanning probe microscopy and the dynamic characteristics of cantilevers. First, the finite element analysis is made fur the vibration characteristics of various cantilevers in use. The computed natural frequencies of the cantilevers are in good agreement with measured ones. Then, each cantilever is tested with topographic measurement for a standard sample with the scanning speed changed. The performances of cantilevers are analyzed along with the natural frequencies of cantilevers. Experiments are also performed to test the effects of how to attach cantilevers in the piezo-electric actuator. Finally, measurement sensitivity has been analyzed to enhance the performance of scanning probe microscopy.

  • PDF

A Study on Graylevel Image Scanning System Realization Using CIS (CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;김윤호;류광렬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.581-584
    • /
    • 2002
  • The graylevel image scanning system realization and design using CIS(Contact Image Scanning)be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for image processing., and transfer input image data par line in feeding a step unit to PC on the USB interfacer. This system is portable and A4 size scanning and keeps image scan processing speed 300mm/sec The recognition percentage has 98% on the OCR and bar codes.

  • PDF

Preconditions for High Speed Confocal Image Acquisition with DMD Scanning.

  • Shim, S.B.;Lee, K.J.;Lee, J.H.;Hwang, Y.H.;Han, S.O.;Pak, J.H.;Choi, S.E.;Milster, Tom D.;Kim, J.S.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 한국광학회 2006년도 하계학술발표회 논문집
    • /
    • pp.39-40
    • /
    • 2006
  • Digital image-projection and several modifications are the classical applications of Digital Micromirror Devices (DMD), however further applications in the field of optical metrology are also available. Operated with certain patterns, a DMD can function, for instance, as an array of pinholes that may substitute the Galvanic mirror or the stage scanning system presently used for 2 dimensional scanning in confocal microscopes. The various process parameters that influence the result of measurement (e.g. pinhole size, lateral scanning pitch and the number of pinholes used simultaneously, etc.) should be configured precisely for individual measurements by appropriately operating the DMD. This paper presents suitable conditions for the diffraction limited analysis between DMD-optics-CCD to achieve the best performance. Also sampling theorem that is necessary for the image acquisition by scanning system is simulated with OPTISCAN which is the simulator based on the diffraction theory.

  • PDF

Narrow Resonant Double-Ridged Rectangular Waveguide Probe for Near-Field Scanning Microwave Microscopy

  • Kim, Byung-Mun;Son, Hyeok-Woo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.406-412
    • /
    • 2018
  • In this paper, we propose a narrow resonant waveguide probe that can improve the measurement sensitivity in near-field scanning microwave microscopy. The probe consists of a metal waveguide incorporating the following two sections: a straight section at the tip of the probe whose cross-section is a double-ridged rectangle, and whose height is much smaller than the waveguide width; and a standard waveguide section. The advantage of the narrow waveguide is the same as that of the quarter-wave transformer section i.e., it achieves impedance-matching between the sample under test (SUT) and the standard waveguide. The design procedure used for the probe is presented in detail and the performance of the designed resonant probe is evaluated theoretically by using an equivalent circuit. The calculated results are compared with those obtained using the finite element method (Ansoft HFSS), and consistency between the results is demonstrated. Furthermore, the performance of the fabricated resonant probe is evaluated experimentally. At X-band frequencies, we have measured the one-dimensional scanning reflection coefficient of the SUT using the probe. The sensitivity of the proposed resonant probe is improved by more than two times as compared to a conventional waveguide cavity type probe.