• Title/Summary/Keyword: Scanning

Search Result 14,168, Processing Time 0.041 seconds

A STUDY ON THE RELATIONS OF VARIOUS PARTS OF THE PALATE FOR PRIMARY AND PERMANENT DENTITION (유치열과 영구치열의 구개 각부의 관계에 관한 연구)

  • Lee, Yong-Hoon;Yang, Yeon-Mi;Lee, Yong-Hee;Kim, Sang-Hoon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.569-578
    • /
    • 2004
  • The purpose of this study was to clarify the palatal arch length, width and height in the primary and permanent dentition. Samples were consisted of normal occlusions both in the primary dentition(50 males and 50 females) and in the permanent dentition(50 males and 50 females). With their upper plaster casts were used and through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), cloud data, polygonization, section curve and loft surface, fit and horizontal plane were based to measure the palatal arch length, width and height(Surfacer 10.0, Imageware, U.S.A.). T-tests were applied for the statistical analyze of the data. The results were as follows : 1. In the measurement values, the values of the male were higher than those of the female except primary anterior palatal height. There were not only statistically significant differences in anterior palatal width(p<0.05) and posterior palatal width(p<0.01) in primary dentition but palatal width(p<0.05), anterior palatal length(p<0.01), middle and posterior palatal length(p<0.05) in permanent dentition between male and female. 2. In the indices of palate, there were statistically significant differences in height-length index(p<0.05) and width-length index(p<0.01) between male and female in primary dentition. In permanent dentition, there was statistically difference between male and female. 3. In the measurement values, posterior palatal width was increased most greatly. Posterior palatal height, anterior palatal width and anterior palatal length were followed by descending order. On the other hand, anterior palatal height and posterior palatal length were decreased. 4. In the indices of palate, the height-length index, the width-length index and posterior height-width index were increased, but the others were decreased.

  • PDF

Development of Quantification Methods for the Myocardial Blood Flow Using Ensemble Independent Component Analysis for Dynamic $H_2^{15}O$ PET (동적 $H_2^{15}O$ PET에서 앙상블 독립성분분석법을 이용한 심근 혈류 정량화 방법 개발)

  • Lee, Byeong-Il;Lee, Jae-Sung;Lee, Dong-Soo;Kang, Won-Jun;Lee, Jong-Jin;Kim, Soo-Jin;Choi, Seung-Jin;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.486-491
    • /
    • 2004
  • Purpose: factor analysis and independent component analysis (ICA) has been used for handling dynamic image sequences. Theoretical advantages of a newly suggested ICA method, ensemble ICA, leaded us to consider applying this method to the analysis of dynamic myocardial $H_2^{15}O$ PET data. In this study, we quantified patients' blood flow using the ensemble ICA method. Materials and Methods: Twenty subjects underwent $H_2^{15}O$ PET scans using ECAT EXACT 47 scanner and myocardial perfusion SPECT using Vertex scanner. After transmission scanning, dynamic emission scans were initiated simultaneously with the injection of $555{\sim}740$ MBq $H_2^{15}O$. Hidden independent components can be extracted from the observed mixed data (PET image) by means of ICA algorithms. Ensemble learning is a variational Bayesian method that provides an analytical approximation to the parameter posterior using a tractable distribution. Variational approximation forms a lower bound on the ensemble likelihood and the maximization of the lower bound is achieved through minimizing the Kullback-Leibler divergence between the true posterior and the variational posterior. In this study, posterior pdf was approximated by a rectified Gaussian distribution to incorporate non-negativity constraint, which is suitable to dynamic images in nuclear medicine. Blood flow was measured in 9 regions - apex, four areas in mid wall, and four areas in base wall. Myocardial perfusion SPECT score and angiography results were compared with the regional blood flow. Results: Major cardiac components were separated successfully by the ensemble ICA method and blood flow could be estimated in 15 among 20 patients. Mean myocardial blood flow was $1.2{\pm}0.40$ ml/min/g in rest, $1.85{\pm}1.12$ ml/min/g in stress state. Blood flow values obtained by an operator in two different occasion were highly correlated (r=0.99). In myocardium component image, the image contrast between left ventricle and myocardium was 1:2.7 in average. Perfusion reserve was significantly different between the regions with and without stenosis detected by the coronary angiography (P<0.01). In 66 segment with stenosis confirmed by angiography, the segments with reversible perfusion decrease in perfusion SPECT showed lower perfusion reserve values in $H_2^{15}O$ PET. Conclusions: Myocardial blood flow could be estimated using an ICA method with ensemble learning. We suggest that the ensemble ICA incorporating non-negative constraint is a feasible method to handle dynamic image sequence obtained by the nuclear medicine techniques.

Serial Changes of Serum Thyroid-Stimulating Hormone after Total Thyroidectomy or Withdrawal of Suppressive Thyroxine Therapy in Patients with Differentiated Thyroid Cancer (분화성 갑상선 암 환자에서 갑상선 전절제술후 또는 갑상선 호르몬 억제 요법 중단에 따른 갑상선 자극호르몬의 변화)

  • Bae, Jin-Ho;Lee, Jae-Tae;Seo, Ji-Hyoung;Jeong, Shin-Young;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ahn, Byeong-Cheol;Sohn, Jin-Ho;Kim, Bo-Wan;Park, June-Sik;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.516-521
    • /
    • 2004
  • Background: Radioactive iodine (RAI) therapy and whole-body scanning are the fundamentals of treatment and follow-up of patients with differentiated thyroid cancer. It is generally accepted that a Thyroid-Stimulating Hormone (TSH) level of at least 30 ${\mu}U/ml$ is a prerequisite for the effective use of RAI, and that it requires 4-6 weeks of off-thyroxine to attain these levels. Because thyroxine withdrawal and the consequent hypothyroidism are often poorly tolerated, and occasionally might be hazardous, it is important to be certain that these assumptions are correct. We have measured serial changes in serum TSH after total thyroidectomy or withdrawl of thyroxine in patients with thyroid cancer. Subjects and Methods: Serum TSH levels were measured weekly after thyroidectomy in 10 patients (group A) and after the discontinuation of thyroxine in 12 patients (group B). Symptoms and signs of hypothyroidism were also evaluated weekly by modified Billewicz diagnostic index. Results: By the second week, 78% of group A patients and 17% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the third week, 89% of group A patients and 90% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the fourth week, all patients in two groups achieved target TSH levels and there were no overt hypothyroidism. Conclusion: in all patients, serum TSH elevated to the target concentration (${\geq}30{\mu}U/ml$) within 4 weeks without significant manifestation of hypothyroidism. The schedule of RAI administration could be adjusted to fit the needs and circumstances of individual patients with a shorter preparation period than the conventional.

Fundamental Studies on the Ultrasonographic Diagnosis in Korean Native Cattle (한우에서의 초음파화상진단에 관한 연구)

  • Kim Myung-cheol;Park Kwan-ho
    • Journal of Veterinary Clinics
    • /
    • v.12 no.1
    • /
    • pp.861-876
    • /
    • 1995
  • This study was carried out to get fundamental information about the normal ultrasonogram of the liver and heart in Korean native cattle and calves. The interventricular septum, left ventricular internal diameter, left ventricular free wall thickness, aortic diameter, left atrial diameter, and right ventricular internal diameter of hear in 10 Korean native calves were determined at 4-5 right intercostal spare by use of ultrasonography. The caudal vena cava, portal vein, gallbladder, liver of 9 Korean native cattle and 10 calves were determined at 12, 11 and 10th intercostal spares by use of ultrasonography. Cursor-directed M-mode and gray-scale, B-mode ultrasonograms were obtained with electronic scanning ultrasound equipment with a 3.5 or 5.0-MHz convex transducer. The results obtained through the experiments were summarized as follows: 1. The result of ultrasonographic examination of the korean native calves' heart 1) Interventricular septum in systole and diastole was 1.23 and 0.81 cm, respectively(vc=28.84, 17.4). 2) Ventricular internal diameter in systole and diastole was 2.50 and 4.91 cm, respectively(vc=17.44, 12.73). 3) Left ventricular free was thickness in systole and diastole was 1.44 and 0.92 cm, respectively(vc=26.85, 23.54). 4) Aortic diameter was 2.69.m, .rspectevely(vc=11.29). 5) Left atrial diameter was 1.82 cm(vc=15.31). 6) Right ventricular internal diameter in systole and diastole was 1.12 and 1.9 cm, respectively(vc=33.71, 24.43). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native calves 1) Dorsal margin of caudal vena cava at the 12, 11 and 10th intercostal space was 13.5, 15.3 and 18.1 cm, respectively(p<0.01). 3) Depth of caudal vena cava at the 12, 11 and 10th intercostal space was 4.4, 4.5 and 4.6 cm, respectively. 3) Diameter of caudal vena cava at the 12, 11 and 10th intercostal space was 11.6, 1.7 and 1.6 cm, respectively. 4) Dorsal margin of portal vein at the 12, 11 and 10th intercostal space was 16.2, 18.6 and 21.4 cm, respectively(p<0.01) 5) Depth of portal vein at the 12, 11 and 10th intercostal spare was 4.5, 4.4 and 3.9 cm respectively. 6) Diameter of portal vein at the 13, 11 and 10th intercostal space was 2.1, 2.2 and 1.9 cm respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 23.6 and 23.9 cm, respectively(p<0.01), 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 7.1 and 5.9 cm, respectively(p<0.05). 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 2.4 and 2.1 cm respectively(p<0.01). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native cattle 1) Dorsal margin of caudal vena cava at the 12 and 11th intercostal space was 22.2, and 25.4 cm, respectively(p<0.01). 2) Depth of caudal vena cava at the 12 and 11th intercostal space was 103 and 11.1 cm, respectively(p<0.01). 3) Diameter of caudal vena cava at the 12 and 11th intercostal space was 3.1 and 3.0 cm, respectively. 4) Dorsal margin of portal vein at the 12 and 11th intercostal space was 29.3 and 32.9 cm, respectively(p<0.01). 5) Depth of portal vein at the 12 and 11th intercostal space was 9.6, and 9.2 cm, respectively. 6) Diameter of portal vein at the 12 and lith intercostal space was 3.4 and 3.3 cm, respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 43.1 and 45.5 cm, respectively(p<0.01). 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 10.1 and 9.4 cm, respectively. 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 4.0 and 3.7 cm, respectively. 4, Ultrasonogaphic measurments of dorsal margin, ventral margin, size and angles of the Korean native calves' liver. 1) Dorsal margin of liver at the 12, 11 and 10th intercostal space was 11.0, 9.6, and 12.4 cm, respectively(p<0.01). 2) Ventral margin of liver at the 12, 11 and 10th intercostal spate was 20, 24 and 26.1 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 9.0, 14.6 and 13.8 cm, respectively(p<0.01). 4) Angle of liver at the 12, 11 and 10th intercostal space was 40, 46 and 37, respectively(p<0.01). 5. Ultrasonographic measurmants of dorsal margin, ventral margin, size and anglses of the korean native cattle's liver 1) Dorsal margin of the liver at the 12, 11 and 10th intercostal space was 14.4, 18.2 and 26, 3 cm, respectively. 2) Ventral margin of liver at the 12, 11 and 10th intercostal space was 41.1, 46.4 and 49.3 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 26.8, 28.2 and 23.2 cm, respectively(p<0.01). 4) Angel of liverat the 15, 11 and 10 intercostal space was 41, 40.6 and 35.7, respectively(p<0.05). It was concluded that the ultrasonographic values oletermined in this study can be used as references for the diagnosis of morphologic changes in the hear and liver in korean native calves, and in the liver in korean native rattle.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Current Status and Perspectives in Varietal Improvement of Rice Cultivars for High-Quality and Value-Added Products (쌀 품질 고급화 및 고부가가치화를 위한 육종현황과 전망)

  • 최해춘
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47
    • /
    • pp.15-32
    • /
    • 2002
  • The endeavors enhancing the grain quality of high-yielding japonica rice were steadily continued during 1980s-1990s along with the self-sufficiency of rice production and the increasing demands of high-quality rices. During this time, considerably great progress and success was obtained in development of high-quality japonica cultivars and quality evaluation techniques including the elucidation of interrelationship between the physicochemical properties of rice grain and the physical or palatability components of cooked rice. In 1990s, some high-quality japonica rice cultivars and special rices adaptable for food processing such as large kernel, chalky endosperm, aromatic and colored rices were developed and its objective preference and utility was also examined by a palatability meter, rapid-visco analyzer and texture analyzer, Recently, new special rices such as extremely low-amylose dull or opaque non-glutinous endosperm mutants were developed. Also, a high-lysine rice variety was developed for higher nutritional utility. The water uptake rate and the maximum water absorption ratio showed significantly negative correlations with the K/Mg ratio and alkali digestion value(ADV) of milled rice. The rice materials showing the higher amount of hot water absorption exhibited the larger volume expansion of cooked rice. The harder rices with lower moisture content revealed the higher rate of water uptake at twenty minutes after soaking and the higher ratio of maximum water uptake under the room temperature condition. These water uptake characteristics were not associated with the protein and amylose contents of milled rice and the palatability of cooked rice. The water/rice ratio (in w/w basis) for optimum cooking was averaged to 1.52 in dry milled rices (12% wet basis) with varietal range from 1.45 to 1.61 and the expansion ratio of milled rice after proper boiling was average to 2.63(in v/v basis). The major physicochemical components of rice grain associated with the palatability of cooked rice were examined using japonica rice materials showing narrow varietal variation in grain size and shape, alkali digestibility, gel consistency, amylose and protein contents, but considerable difference in appearance and texture of cooked rice. The glossiness or gross palatability score of cooked rice were closely associated with the peak, hot paste and consistency viscosities of viscosities with year difference. The high-quality rice variety "IIpumbyeo" showed less portion of amylose on the outer layer of milled rice grain and less and slower change in iodine blue value of extracted paste during twenty minutes of boiling. This highly palatable rice also exhibited very fine net structure in outer layer and fine-spongy and well-swollen shape of gelatinized starch granules in inner layer and core of cooked rice kernel compared with the poor palatable rice through image of scanning electronic microscope. Gross sensory score of cooked rice could be estimated by multiple linear regression formula, deduced from relationship between rice quality components mentioned above and eating quality of cooked rice, with high probability of determination. The $\alpha$-amylose-iodine method was adopted for checking the varietal difference in retrogradation of cooked rice. The rice cultivars revealing the relatively slow retrogradation in aged cooked rice were IIpumbyeo, Chucheongyeo, Sasanishiki, Jinbubyeo and Koshihikari. A Tonsil-type rice, Taebaegbyeo, and a japonica cultivar, Seomjinbyeo, showed the relatively fast deterioration of cooked rice. Generally, the better rice cultivars in eating quality of cooked rice showed less retrogradation and much sponginess in cooled cooked rice. Also, the rice varieties exhibiting less retrogradation in cooled cooked rice revealed higher hot viscosity and lower cool viscosity of rice flour in amylogram. The sponginess of cooled cooked rice was closely associated with magnesium content and volume expansion of cooked rice. The hardness-changed ratio of cooked rice by cooling was negatively correlated with solids amount extracted during boiling and volume expansion of cooked rice. The major physicochemical properties of rice grain closely related to the palatability of cooked rice may be directly or indirectly associated with the retrogradation characteristics of cooked rice. The softer gel consistency and lower amylose content in milled rice revealed the higher ratio of popped rice and larger bulk density of popping. The stronger hardness of rice grain showed relatively higher ratio of popping and the more chalky or less translucent rice exhibited the lower ratio of intact popped brown rice. The potassium and magnesium contents of milled rice were negatively associated with gross score of noodle making mixed with wheat flour in half and the better rice for noodle making revealed relatively less amount of solid extraction during boiling. The more volume expansion of batters for making brown rice bread resulted the better loaf formation and more springiness in rice breed. The higher protein rices produced relatively the more moist white rice bread. The springiness of rice bread was also significantly correlated with high amylose content and hard gel consistency. The completely chalky and large grain rices showed better suitability far fermentation and brewing. The glutinous rice were classified into nine different varietal groups based on various physicochemical and structural characteristics of endosperm. There was some close associations among these grain properties and large varietal difference in suitability to various traditional food processing. Our breeding efforts on improvement of rice quality for high palatability and processing utility or value-adding products in the future should focus on not only continuous enhancement of marketing and eating qualities but also the diversification in morphological, physicochemical and nutritional characteristics of rice grain suitable for processing various value-added rice foods.ice foods.

A Study on the Conservation State and Plans for Stone Cultural Properties in the Unjusa Temple, Korea (운주사 석조문화재의 보존상태와 보존방안에 대한 연구)

  • Sa-Duk, Kim;Chan-Hee, Lee;Seok-Won, Choi;Eun-Jeong, Shin
    • Korean Journal of Heritage: History & Science
    • /
    • v.37
    • /
    • pp.285-307
    • /
    • 2004
  • Synthesize and examine petrological characteristic and geochemical characteristic by weathering formation of rock and progress of weathering laying stress on stone cultural properties of Unjusa temple of Chonnam Hwasun county site in this research. Examine closely weathering element that influence mechanical, chemical, mineralogical and physical weathering of rocks that accomplish stone cultural properties and these do quantification, wish to utilize by a basic knowledge for conservation scientific research of stone cultural properties by these result. Enforced component analysis of rock and mineralogical survey about 18 samples (pyroclastic tuff; 7, ash tuff; 4, granite ; 4, granitic gneiss; 3) all to search petrological characteristic and geochemical characteristic by weathering of Unjusa temple precinct stone cultural properties and recorded deterioration degree about each stone cultural properties observing naked eye. Major rock that constitution Unjusa temple one great geological features has strike of N30-40W and dip of 10-20NE being pyroclastic tuff. This pyroclastic tuff is ranging very extensively laying center on Unjusa temple and stone cultural properties of precinct is modeled by this pyroclastic tuff. Stone cultural propertieses of present Unjusa temple precinct are accomplishing structural imbalance with serious crack, and because weathering of rock with serious biological pollution is gone fairly, rubble break away and weathering and deterioration phenomenon such as fall off of a particle of mineral are appearing extremely. Also, a piece of iron and cement mortar of stone cultural properties everywhere are forming precipitate of reddish brown and light gray being oxidized. About these stone cultural properties, most stone cultural propertieses show SD(severe damage) to MD(moderate damage) as result that record Deterioration degree. X-ray diffraction analysis result samples of each rock are consisted of mineral of quartz, orthoclase,plagioclase, calcite, magnetite etc. Quartz and feldspar alterated extremely in a microscopic analysis, and biotite that show crystalline form of anhedral shows state that become chloritization that is secondary weathering mineral being weathered. Also, see that show iron precipitate of reddish brown to crack zone of tuff everywhere preview rock that weathering is gone deep. Tuffs that accomplish stone cultural properties of study area is illustrated to field of Subalkaline and Peraluminous, $SiO_2$(wt.%) extent of samples pyroclastic tuff 70.08-73.69, ash tuff extent of 70.26-78.42 show. In calculate Chemical Index of Alteration(CIA) and Weathering Potential Index(WPI) about major elements extent of CIA pyroclastic tuff 55.05-60.75, ash tuff 52.10-58.70, granite 49.49-51.06 granitic gneiss shows value of 53.25-67.14 and these have high value gneiss and tuffs. WPI previews that is see as thing which is illustrated being approximated in 0 lines and 0 lines low samples of tuffs and gneiss is receiving esaily weathering process as appear in CIA. As clay mineral of smectite, zeolite that is secondary weathering produce of rock as result that pick powdering of rock and clothing material of stone cultural properties observed by scanning electron micrographs (SEM). And roots of lichen and spore of hyphae that is weathering element are observed together. This rock deep organism being coating to add mechanical weathering process of stone cultural properties do, and is assumed that change the clay mineral is gone fairly in stone cultural properties with these. As the weathering of rocks is under a serious condition, the damage by the natural environment such as rain, wind, trees and the ground is accelerated. As a counter-measure, the first necessary thing is to build the ground environment about protecting water invasion by making the drainage and checking the surrounding environment. The second thing are building hardening and extirpation process that strengthens the rock, dealing biologically by reducing lichens, and sticking crevice part restoration using synthetic resin. Moreover, it is assumed to be desirable to build the protection facility that can block wind, sunlight, and rain which are the cause of the weathering, and that goes well with the surrounding environment.