• 제목/요약/키워드: Scanned points

검색결과 114건 처리시간 0.031초

The simulation for error analysis of a large scale laser digitizer system

  • Fujimoto, Ikumatsu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.440-445
    • /
    • 1993
  • A two dimensional large scale laser digitizer with a cordless cursor was developed. The coordinate detecting scheme of this digitizer is fundamentally based on the triangulation method, in which two laser-rays are scanned by the rotating plane mirros, reflected backward by the cursor, reflected again by the rotating mirrors, and detected by optical sensors. From angles in which the cursor reflections are detected, we can determine the position of the cursor. But this method involves several problems about optical alignment and its calibration especially when it is applied to a large scale digitizer. In this paper, especially we propose simulation for error analysis with connection to angles measured at five control points which are needed to decide an appropriate model for calculating coordinates and optimal simulation for deciding the position of five control points to give the better coordinate accuracy. In this way, we realized the on-site calibration and on-site insurance of measurement accuracy with our appropriate model for calculating coordinates. The time required for on-site calibration is within 5 minutes and the average accuracy of 4m * 3m digitizer is about .+-.0.12mm.

이진 영상점들에 대한 구역별 직선 근사화 (Piecewise-Linear Curve Approximation for a Set of Digital Points)

  • 이문규;이백
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2003년도 춘계공동학술대회
    • /
    • pp.1122-1127
    • /
    • 2003
  • Typical application of detecting piecewise-linear curves includes vectorizing of scanned drawings whirh is a vital step in installing any geographic information system. This paper considers the problem of optimally approximating a piecewise linear curve to a set of digital points while satisfying given intersection angles between each pair of neighboring lines. The criterion for optimality is to minimize the sum of squared deviations. The problem is formulated as an unconstrained nonlinear programming model. An algorithm which guarantees an optimal solution is then proposed and its validity is tested with both a synthetically generated image and a real image. The test results illustrate the excellent performance of the proposed algorithm.

  • PDF

등고선 벡터라이징을 위한 끊어진 등고선의 자동 연결 기법 (An Automatic Connection Scheme of Disconnected Contours for the Vectorizing of Contours)

  • 전일수;남인길
    • 한국산업정보학회논문지
    • /
    • 제5권4호
    • /
    • pp.60-66
    • /
    • 2000
  • 본 논문에서는 등고선 자동 벡터화 시스템 개발을 위해 등고선의 끊어짐을 포함하는 스캔된 등고선 이미지에서 등고선을 연결하는 기법을 제안한다. 제안된 기법에서는 등고선의 세선화를 먼저 수행하고 나서 끊어진 선들을 연결한다. 등고선들은 끊어짐이 존재하면 끝점들을 가지므로 이들 끝점 쌍들을 연속적으로 연결하여 하나의 등고선이 하나의 연결요소를 이루도록 연결한다. 제안된 기법은 효율적인 등고선 자동벡터화 시스템을 개발하는데 적용될 수 있다.

  • PDF

도심지 지상 LiDAR 자료의 Geo-Referencing을 위한 기준점 선정 및 특징점 측량 방안 연구 (A Study on Determining Control Points and Surveying Feature Points for Geo-Referencing of Terrestrial LiDAR Data in Urban Areas)

  • 박효근;한수희;조형식;김성훈;손홍규;허준
    • 한국측량학회지
    • /
    • 제28권1호
    • /
    • pp.179-186
    • /
    • 2010
  • 본 연구에서는, 건물이 밀집한 도심지를 대상으로 취득한 지상 LiDAR 자료의 geo-referencing을 위해 필요한 특정정의 절대좌표를 효율적으로 취득할 수 있는 방안을 모색하였다. 도심지에서는 GPS 신호 수신의 문제점, 다각측량 및 수준측량을 통한 원거리 기준점 측량의 비용적 문제점 등이 발생할 수 있으며 이를 극복하기 위하여 건물의 옥상에서 GPS 측량을 통해 기준점을 설치하고 특징점의 절대좌표를 취득하는 방식을 제안하였다. 제안된 방식에서는 옥상에서의 지상 레이저 스캐닝이 가능할 경우 기준점 자체를 특징점으로 사용함으로써 별도의 특징점 선정 및 측량을 필요로 하지 않으며 안정적인 스캐닝도 보장받을 수 있다. 실제 대상지역에 적용한 결과 본 연구에서 제안된 방식이 기존 방식에 비하여 충분히 비용 효율적일 수 있다는 가능성을 확인하였다.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas

  • Yus, Estefania Aranda;Cantarell, Josep Maria Anglada;Alonso, Antonio Minarro
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.236-244
    • /
    • 2018
  • PURPOSE. To determine the discrepancy in monolithic zirconium dioxide crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems by comparing scans of silicone impressions and of master casts. MATERIALS AND METHODS. From a Cr-Co master die of a first upper left molar, 30 silicone impressions were taken. The 30 silicone impressions were scanned with the laboratory scanner, thus obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the silicone group). They were poured and the working models were scanned, obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the plaster group). Three predetermined points were analyzed in each side of the crown (Mesial, Distal, Vestibular and Palatal), and the marginal fit was evaluated with SEM (${\times}600$). The response variable is the discrepancy from the master model. A repeated measures ANOVA with two within subject factors was performed to study significance of main factors and interaction. RESULTS. Mean marginal discrepancy was $22.42{\pm}35.65{\mu}m$ in the silicone group and $8.94{\pm}14.69{\mu}m$ in the plaster group. The statistical analysis showed significant differences between the two groups and also among the four aspects. Interaction was also significant (P=.02). CONCLUSION. The mean marginal fit values of the two groups were within the clinically acceptable values. Significant differences were found between the groups according to the aspects studied. Various factors influenced the accuracy of digitizing, such as the design, the geometry, and the preparation guidance, as well as the texture, roughness and the color of the scanned material.

3D 스캔 데이터를 이용한 얼굴 애니메이션 시스템 (A Facial Animation System Using 3D Scanned Data)

  • 구본관;정철희;이재윤;조선영;이명원
    • 정보처리학회논문지A
    • /
    • 제17A권6호
    • /
    • pp.281-288
    • /
    • 2010
  • 본 논문에서는 3차원 얼굴 스캔 데이터와 사진 이미지를 이용하여 고화질의 3차원 얼굴 모델과 모핑 애니메이션을 생성하는 시스템 개발에 대해 기술한다. 본 시스템은 얼굴 특징점 입력 도구, 얼굴 텍스처매핑 인터페이스, 3차원 얼굴 모핑 인터페이스로 구성되어 있다. 얼굴 특징점 입력 도구는 3차원 텍스처매핑과 모핑 애니메이션을 위한 보조 도구로서 얼굴의 특징점을 입력하여 텍스처매핑과 임의의 두 얼굴간의 모핑 영역을 정할 때 사용된다. 텍스처매핑은 3D 스캐너로부터 획득한 얼굴의 기하 데이터에 세 방향의 사진 이미지를 이용하여 매핑한다. 3D 얼굴모핑은 얼굴 특징점 입력 도구로부터 얻은 특징점을 중심으로 얼굴 영역을 분류하여 임의의 두 얼굴 간의 영역간 매핑을 실현한다. 본 시스템은 사용자가 별도의 프로그래밍 작업 없이 대화형 인터페이스에서 3D 스캐너에서 획득한 얼굴 메쉬 데이터를 이용하여 사진 이미지로 텍스처 매핑을 실행하여 사실적인 3D 얼굴 모델을 얻을 수 있고, 임의의 서로 다른 얼굴 모델들간의 모핑 애니메이션을 쉽게 실현할 수가 있다.

STL 메쉬를 이용한 자유곡면의 레이저 측정경로 생성 연구 (STL mesh based laser scan planning system for complex freeform surfaces)

  • 손석배;김승만;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.595-598
    • /
    • 2002
  • Laser scanners are getting used more and more in reverse engineering and inspection. For CNC-driven laser scanners, it is important to automate the scanning operations to improve the accuracy of capture point data and to reduce scanning time in industry. However, there are few research works on laser scan planning system. In addition, it is difficult to directly analyze multi-patched freeform models. In this paper, we propose an STL (Stereolithography) mesh based laser scan planning system for complex freeform surfaces. The scan planning system consists of three steps and it is assumed that the CAD model of the part exists. Firstly, the surface model is approximated into STL meshes. From the mesh model, normal vector of each node point is estimated. Second, scan directions and regions are determined through the region growing method. Also, scan paths are generated by calculating the minimum-bounding rectangle of points that can be scanned in each scan direction. Finally, the generated scan directions and paths are validated by checking optical constraints and the collision between the laser probe and the part to be scanned.

  • PDF

건설현장 3차원 점군 데이터 정합 정확성 향상을 위한 중첩비율 분석 (Analysis of overlap ratio for registration accuracy improvement of 3D point cloud data at construction sites)

  • 박수열;김석
    • 한국BIM학회 논문집
    • /
    • 제11권4호
    • /
    • pp.1-9
    • /
    • 2021
  • Comparing to general scanning data, the 3D digital map for large construction sites and complex buildings consists of millions of points. The large construction site needs to be scanned multiple times by drone photogrammetry or terrestrial laser scanner (TLS) survey. The scanned point cloud data are required to be registrated with high resolution and high point density. Unlike the registration of 2D data, the matrix of translation and rotation are used for registration of 3D point cloud data. Archiving high accuracy with 3D point cloud data is not easy due to 3D Cartesian coordinate system. Therefore, in this study, iterative closest point (ICP) registration method for improve accuracy of 3D digital map was employed by different overlap ratio on 3D digital maps. This study conducted the accuracy test using different overlap ratios of two digital maps from 10% to 100%. The results of the accuracy test presented the optimal overlap ratios for an ICP registration method on digital maps.

Anterior and Posterior Overjet for Clinical Arch Coordination using 3-dimensional Analysis

  • Lee, Young-Wuk;Bayome, Mohamed;Baek, Seung-Hak;Kook, Yoon-Ah
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.18-23
    • /
    • 2009
  • Introduction : The purposes of this study were to analyze the differences between the anterior and posterior overjets using bracket slot points, and compare two methods of overjet calculation according to different reference points using clinical bracket points on three-dimensional digital models. Methods : A total of 35 normal occlusion models were scanned using a three-dimensional scanner (Orapix$^{(R)}$, Orapix Co., Ltd, Seoul, Korea) and then, virtual brackets (0.022" Slot MBT preadjusted brackets, 3 M Co.CA. USA) were placed on the digital models using virtual setup program (3Txer$^{(R)}$ ver. 1.9.6, Orapix co., Ltd). Archwire-like curves were designed to analyze labial and buccal overjet. Results : There were no statistically significance differences between the right and left overjet and between genders. The average overjet was found to be $1.67{\pm}0.85mm$ at the central incisor area, $2.16{\pm}0.88mm$ at the second premolar and $1.53{\pm}0.71mm$ at the first molar. Conclusion : It is recommended that overjet of individualized upper and lower arch to be 2.0mm at the anterior and posterior teeth.

  • PDF