• Title/Summary/Keyword: Scan motion

Search Result 159, Processing Time 0.027 seconds

3D Deinterlacing Algorithm Based on Wide Sparse Vector Correlations

  • Kim, Yeong-Taeg
    • Journal of Broadcast Engineering
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1996
  • In this paper, we propose a new 3-D deinterlacing algorithm based on wide sparse vector correlations and a vertical edge based motion detection algorithm. which is an extension of the deinterlacing algorithm proposed in [10. llJ by the authors. The prooised algorithm is developed mainly for the format conversion problem encountered in current HDTV system, but can also be aplicable to the double scan conversion problesm frequently encountered in ths NTSC systems. By exploiting the edge oriented spatial interpolation based on the wide vector correlations, visually annoying artifiacts caused by interlacing such as a serrate line. line crawling, a line flicker, and a large area flicker can be remarkably reduced since the use of the wide vectors increases the range of the edge orientations that can be detected, and by exploiting sparse vectors correlations the HjW complexity for realizing the algorithm in applications cam be significantly simplified. Simulations are provided indicating thet the proposed algorithm results in a high performance comparable to the performance of the deinterlacing algorithm. based on the wide vector correlations.

  • PDF

Digital Hologram Coding Technique using Block Matching of Localized Region and MCTF (로컬영역의 정합기법 및 MCTF를 이용한 디지털 홀로그램 부호화 기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kim, Dong-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.415-416
    • /
    • 2006
  • In this paper, we proposed a new coding technique of digital hologram video using 3D scanning method and video compression technique. The proposed coding consists of capturing a digital hologram to separate into RGB color space components, localization by segmenting the fringe pattern, frequency transform using $M{\tiems}N$ (segment size) 2D DCT (2 Dimensional Discrete Cosine Transform) for extracting redundancy, 3D scan of segment to form a video sequence, motion compensated temporal filtering (MCTF) and modified video coding which uses H.264/AVC.

  • PDF

Atmospheric Metal Doping System and Application for Poly-Si Backplane

  • Shin, D.H.;Lee, J.M.;Lee, S.K.;Kim, H.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.87-90
    • /
    • 2007
  • VIATRON TECHNOLOGIES has developed an $\underline{A}$tmospheric $\underline{M}$etal $\underline{D}$oping (AMD) system which uniformly dopes metal species onto a substrate. The AMD system injects metal-organic vapor over substrate using an injection head with a scan motion. One of important application of this system is a metalinduced crystallization of amorphous Si for manufacturing AMOLED poly-Si panels. The AMD system with a use of Ni vapor source produces doping of trace amount of Ni onto amorphous Si, enabling uniform MIC crystallization. Also, the operation without vacuum condition offers advantages such as easy maintenance, low cost production, and large glass processes.

  • PDF

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

The Effect of Aquatic Gait Training on Foot Kinesiology and Gait Speed in Right Hemiplegic Patients (수중 걷기 운동이 우측 편마비 환자의 발 운동학과 보행 속도에 미치는 영향)

  • Lee, Sang-Yeol;Hyong, In-Hyouk;Shim, Je-Myung
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.674-682
    • /
    • 2009
  • The purpose of this study was to investigate the effect of aquatic gait training on plantar foot pressure, foot kinesiology and gait speed in right hemiplegic patients. The subject were 20 stroke patients who elapsed from 12 month to 24 month after stroke(aquatic gait training group(n=10), land gait training group(n=10)). This study measured plantar foot pressure, toe out angle, subtalar joint angle, gait speed from data of gate on 2m long measuring apparatus for RS-scan system(RS scan Ltd. German). This experiment performed in twice, before and after the aquatic gait training and land gait training. Collected data were statistically analyzed by SPSS Ver. 12.0 using descriptive statistics, paired t-test. Aquatic gait training group had more variety pressure area on their foot such as T1(Toe 1), HM(Heel medial), and HL(Heel lateral). But motion of subtalar joint flexibility and toe out angle decreased considerably and gate speed also increased. According to the result, aquatic gait training is considered as more effective way in foot stability and normal gait pattern than land gait training.

Operative Treatment of Intraarticular Calcaneal Fractures using Extensile Lateral Approach (광범위 외측 도달법을 이용한 관절내 종골 골절의 수술적 치료)

  • Chung, Hyung-Jin;Ahn, Jong-Kuk;Bae, Su-Young;Jung, Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.60-67
    • /
    • 2009
  • Purpose: This study was designed to investigate the usefulness of extensile lateral approach for accurate reduction and rigid internal fixation in comminuted intraarticular fractures of calcaneus. Materials and Methods: From October 2002 to May 2007, we managed 55 patients (62 cases) with open reduction and internal fixation using extensile lateral approach. Among these, 38 patients (43 cases) who underwent preoperative and postoperative CT scan were enrolled. All patients were evaluated over 24 months after surgery. Bohler angle and Gissane angle on plain X-ray, displacement and step-off of articular surface of calcaneus on CT scan were measured and we compared the difference between preoperative and postoperative value of them. Clinical results were assessed by using AOFAS Ankle-Hindfoot Scale. Results: The average Bohler angle was restored from $6.8^{\circ}$ to $23.5^{\circ}$ and Gissane angle was improved from $116.4^{\circ}$ to $113.5^{\circ}$ after operation. The average distance of displacement was restored from 4.2 mm to 1.4 mm and step-off of articular surface was recovered from 5.1 mm to 1.3 mm. Clinical results were excellent in 17 cases, good in 18 cases, fair in 3 cases, and poor in 5 cases. 10 cases developed postoperative complications such as skin necrosis, heel pain, limitation of motion of ankle and subtalar arthritis. Conclusion: The extensile lateral approach is valuable for the comminuted intraarticular fractures of calcaneus that enables accurate anatomical reduction and rigid internal fixation by providing direct exposure of subtalar joint.

  • PDF

Comparative clinical and radiologic evaluation between patients undergoing standard reversed shoulder arthroplasty or bony increased offset

  • Tiago Amorim-Barbosa;Ana Ribau;Helder Fonte;Luis Henrique Barros;Rui Claro
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.3-9
    • /
    • 2023
  • Background: Modifications of the medialized design of Grammont-type reverse shoulder arthroplasty (RSA) using a bony increased offset (BIO-RSA) has shown better clinical results and fewer complications. The aim of this study is to compare the clinical results, complications, and radiological outcomes between patients undergoing standard RSA and BIO-RSA. Methods: A retrospective review was performed of 42 RSA procedures (22 standard RSA and 20 BIO-RSA). With a minimum of 1 year of follow-up, range of motion (ROM), Constant shoulder score (CSS), visual analog scale (VAS), and subjective shoulder score (SSS) were compared. Radiographs and computed tomography (CT) scan were examined for scapular notching, glenoid and humeral fixation, and graft healing. Results: At a mean follow-up of 27.6 months (range, 12-48 months), a significant difference was found for active-internal rotation (P=0.038) and for passive-external rotation (P=0.013), with better results in BIO-RSA. No other differences were found in ROM, CSS (P=0.884), VAS score, and SSS. Graft healing and viability were verified in all patients with CT scan (n=34). The notching rate was 28% in the standard RSA group and 33% in the BIO-RSA group, but the standard RSA had more severe notching (grade 2) than BIO-RSA (P=0.039). No other significative differences were found in glenoid and humeral fixation. Conclusions: Bone-graft lateralization is associated with better internal and external rotation and with less severe scapular notching compared to the standard RSA. Integration of the bone graft occurs effectively, with no relevant changes observed on radiographic evaluation. Level of evidence: III.

Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity

  • Block, Kai Tobias;Chandarana, Hersh;Milla, Sarah;Bruno, Mary;Mulholland, Tom;Fatterpekar, Girish;Hagiwara, Mari;Grimm, Robert;Geppert, Christian;Kiefer, Berthold;Sodickson, Daniel K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.87-106
    • /
    • 2014
  • Purpose : To describe how a robust implementation of a radial 3D gradient-echo sequence with stack-of-stars sampling can be achieved, to review the imaging properties of radial acquisitions, and to share the experience from more than 5000 clinical patient scans. Materials and Methods: A radial stack-of-stars sequence was implemented and installed on 9 clinical MR systems operating at 1.5 and 3 Tesla. Protocols were designed for various applications in which motion artifacts frequently pose a problem with conventional Cartesian techniques. Radial scans were added to routine examinations without selection of specific patient cohorts. Results: Radial acquisitions show significantly lower sensitivity to motion and allow examinations during free breathing. Elimination of breath-holding reduces failure rates for non-compliant patients and enables imaging at higher resolution. Residual artifacts appear as streaks, which are easy to identify and rarely obscure diagnostic information. The improved robustness comes at the expense of longer scan durations, the requirement for fat suppression, and the nonexistence of a time-to-center value. Care needs to be taken during the configuration of receive coils. Conclusion: Routine clinical use of radial stack-of-stars sequences is feasible with current MR systems and may serve as substitute for conventional fat-suppressed T1-weighted protocols in applications where motion is likely to degrade the image quality.

Quantitative Comparison of Motion Artifacts in PET Images using Data-Based Gating (데이터 기반 게이팅을 이용한 PET 영상의 움직임 인공물의 정량적 비교)

  • Jin Young, Kim;Gye Hwan, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.91-98
    • /
    • 2023
  • PET is used effectively for biochemical or pathological phenomena, disease diagnosis, prognosis determination after treatment, and treatment planning because it can quantify physiological indicators in the human body by imaging the distribution of various biochemical substances. However, since respiratory motion artifacts may occur due to the movement of the diaphragm due to breathing, we would like to evaluate the practical effect by using the a device-less data-driven gated (DDG) technique called MotionFree with the phase-based gating correction method called Q.static scan mode. In this study, images of changes in moving distance (0 cm, 1 cm, 2 cm, 3 cm) are acquired using a breathing-simulated moving phantom. The diameters of the six spheres in the phantom are 10 mm, 13 mm, 17 mm, 22 mm, 28 mm, and 37 mm, respectively. According to maximum standardized uptake value (SUVmax) measurements, when DDG was applied based on the moving distance, the average SUVmax of the correction effect by the moving distance was improved by 1.92, 2.48, 3.23 and 3.00, respectively. When DDG was applied based on the diameter of the phantom spheres, the average SUVmax of the correction effect by the moving distance was improved by 2.37, 2.02, 1.44, 1.20, 0.42 and 0.52 respectively.

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.