• Title/Summary/Keyword: Scan motion

Search Result 159, Processing Time 0.025 seconds

Pedestrians Action Interpretation based on CUDA for Traffic Signal Control (교통신호제어를 위한 CUDA기반 보행자 행동판단)

  • Lee, Hong-Chang;Rhee, Sang-Yong;Kim, Young-Baek
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.5
    • /
    • pp.631-637
    • /
    • 2010
  • In this paper, We propose a method of motion interpretation of pedestrian for active traffic signal control. We detect pedestrian object in a movie of crosswalk area by using the code book method and acquire contour information. To do this stage fast, we use parallel processing based on CUDA (Compute Unified Device Architecture). And we remove shadow which causes shape distortion of objects. Shadow removed object is judged by using the hilbert scan distance whether to human or noise. If the objects are judged as a human, we analyze pedestrian objects' motion, face area feature, waiting time to decide that they have intetion to across a crosswalk for pdestrians. Traffic signal can be controlled after judgement.

Field Mismatch Compensation and Motion Blur Reduction System for Moving Images (동영상의 필드불일치 보정 및 움직임열화 제거 시스템 개발)

  • Choung, Yoo-Chan;Paik, Joon-Ki
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.81-87
    • /
    • 1999
  • In this research, we propose a field mismatch compensation method for interlaced scan image and a image restoration technique for removing motion blur. In order to compensate field mismatch, the edge classification-based linear interpolation technique and the method using the object-based motion compensation are described. We also propose an edge estimation method and an motion-based image segmentation algorithm. For removing motion blur, we adopt an adaptive iterative image restoration method using the motion-based segmentation result to improve the quality of restored image.

  • PDF

Using dental virtual patients with dynamic occlusion in esthetic restoration of anterior teeth: case reports (동적 교합을 나타내는 가상 환자의 형성을 통한 심미적인 전치부 보철 수복 증례)

  • Phil-Joon Koo;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.328-343
    • /
    • 2023
  • Recently, a method of fabricating an esthetic anterior fixed prosthesis by integrating data such as three-dimensional facial scan and jaw motion to form a virtual patient with dynamic occlusion has been introduced. This enables smooth communication with patients during the diagnosis process, improves the predictability of esthetic prosthetic treatment, and lowers the possibility of occlusal adjustment. In this case report, a virtual patient with dynamic occlusion was created in which the results of the treatment were simulated, and esthetic maxillary anterior fixed prosthesis was fabricated. With the aid of the virtual patient, the final restorations were satisfactory both in terms of esthetic and function.

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion (표적이 규칙적으로 움직일 때 생기는 4DCT 영상의 모션 아티팩트(Motion Artifact) 관련된 원인분석)

  • Sheen, Heesoon;Han, Youngyih;Shin, Eunhyuk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2013
  • The aim of this study was to clarify the impacts of acquisition parameters on artifacts in four-dimensional computed tomography (4D CT) images, such as the partial volume effect (PVE), partial projection effect (PPE), and mis-matching of initial motion phases between adjacent beds (MMimph) in cine mode scanning. A thoracic phantom and two cylindrical phantoms (2 cm diameter and heights of 0.5 cm for No.1 and 10 cm for No.2) were scanned using 4D CT. For the thoracic phantom, acquisition was started automatically in the first scan with 5 sec and 8 sec of gantry rotation, thereby allowing a different phase at the initial projection of each bed. In the second scan, the initial projection at each bed was manually synchronized with the inhalation phase to minimize the MMimph. The third scan was intentionally un-synchronized with the inhalation phase. In the cylindrical phantom scan, one bed (2 cm) and three beds (6 cm) were used for 2 and 6 sec motion periods. Measured target volume to true volume ratios (MsTrueV) were computed. The relationships among MMimph, MsTrueV, and velocity were investigated. In the thoracic phantom, shorter gantry rotation provided more precise volume and was highly correlated with velocity when MMimph was minimal. MMimph reduced the correlation. For moving cylinder No. 1, MsTrueV was correlated with velocity, but the larger MMimph for 2 sec of motion removed the correlation. The volume of No. 2 was similar to the static volume due to the small PVE, PPE, and MMimph. Smaller target velocity and faster gantry rotation resulted in a more accurate volume description. The MMimph was the main parameter weakening the correlation between MsTrueV and velocity. Without reducing the MMimph, controlling target velocity and gantry rotation will not guarantee accurate image presentation given current 4D CT technology.

An Effective De-Interlacing Technique Using Bi-directional Motion (양방향 움직임을 사용한 효과적인 디인터레이싱 기법)

  • 정유영;고성제
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.873-876
    • /
    • 2000
  • 본 논문에서는 양방향 움직임 보상에 의한 필드 보간(bi-directional motion-compensated field interpolation) 방법을 사용한 효과적인 디인터레이싱(de-interlacing) 기법을 제안한다. 움직임 추정(motion estimation)을 이용한 일반적인 디인터레이싱 기법은 서로 다른 샘플링 격자(sampling grid) 관계인 연속한 두 필드(field)들간의 움직임 추정을 위해 line average 같은 비교적 간단한 형태의 디인터레이싱 기법이 선행된다. 그러나, 제안한 방법은 보간할 필드(the interpolated field)의 전후 필드들의 같은 샘플링 관계인 존재하는 스캔 라인(the existing scan line)들 사이에서만 움직임 추정이 이루어지므로 구현이 용이하다. 이때 구해진 움직임 벡터는 양방향 움직임 추정을 위한 초기 값으로 사용되어 진다. 제안한 알고리듬은 기존의 움직임 정보를 이용한 기법에 비해 구현이 용이하며, 카메라 움직임이 있는 panning, zooming 영상에 특히 효율적이다.

  • PDF

The design of XYZ 3-axis stage for AFM system (AFM 시스템을 위한 XYZ 3축 스테이지의 설계)

  • 김동민;김기현;심종엽;권대갑;엄천일
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.36-36
    • /
    • 2002
  • To Establish of standard technique of length measurent in 2D plane, we develope AFM system. The XY scanner scans the sample only in XY plane, while the Z scanner scans the specimen only in Z-direction. Cantilever tip is controlled to has constant height relative to speciman surface by feedback of PSPD signal. To acquire high accuracy, Z-axis measuring sensor will be added.(COXI or others). In this paper we design XYZ stage suitable for this AEM system. For XY stage, single module parallel-kinnematic flexure stage is used which has high orthogonality and minimum out-of-plane motion. To obtain best performance optimal design is performed. For XY stage, to be robust about parasitic motion optimal design of maximizing Z and tilt stiffness is performed under the constraint of motion range and stage size. And for Z stage, optimal design of maximizing 1st resonant frequency is performed. Because if resonant frequency is get higher, scan speed is improved. So it makes reduce the error by sensor drift. Resultly XYZ stage each have 1st natural frequency of 115㎐, 201㎐, 2.66㎑ and range 109㎛, 110㎛, 12㎛.

  • PDF

A Study on the Left Ventricular Function Evaluation with ECG Gated Cardiac Blood Pool Scan (ECG Gated Cardiac Blood Poot Scan에서 좌심실기능(左心室機能) 분석(分析)에 관(關)한 연구(硏究))

  • Chung, June-Key;Lee, Jung-Kyoon;Kim, Kwang-Won;Lee, Myung-Chul;Cho, Bo-Yeon;Lee, Young-Woo;Koh, Chang-Soon;Han, Man-Chung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.29-36
    • /
    • 1980
  • Most of clinical morbidity in cardiology are associated with abnormalities of the left ventricle. Several methods have been developed to measure the left ventricular function, including cardiac catheterization with cineangiography, echocardiography, and systolic time interval. But these methods have many limitations. ECG gated cardiac blood pool scan provides a safe, noninvasive, repeatable method for determining the left ventricular function. Utilizing the cardiac blood pool scan, we measured the left ventricular function in 165 cardiac patients, and in 26 normal subject. 1. Left ventricular ejection fractions were measured by cardiac blood pool scan, and compared in 20 patients with that measured by x-ray cineangiography. Correlation coefficient was 0.885. 2. Ejection fractions were classified by funtional class made in New York Heart Association. Ejection fractions well represented the functional status. 3. Ejection fractions decreased in cardiomyopathy ($20.1{\pm}4.8%$) and ischemic heart disease ($34.4{\pm}16.7%$). Impaired ejection fractions in myocardial infarction were associated with the extent of infarction. 4. Regional left ventricular wall motion was evaluated from the end-diastolic and end-systolic images. In cardiomyopathy diffuse hypokinesia was noted and in myocardial infarction akinesia was noted on the infarcted areas.

  • PDF

An analysis on the Fit Preferences of Breeches using 3D Lower Body Scan data (3차원 하반신 스캔데이터를 이용한 승마바지의 맞음새 분석)

  • Kang, Mi-Jung;Kwon, Young-Ah
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.1000-1009
    • /
    • 2013
  • Well-fitting riding breeches provide a comfortable ride. Horse-riding breeches should fit the lower body with patches located on the inside of hip and knees to prevent tears and slips. This study provides information about the fit of women's breeches using 3D human body scan data wearing commercially available two breeches according to posture. To get information about breeches fit, we measured the angle of waist line, the length, and the area of the breeches fit on four 20's women. This research showed the problem which was down for waist back line in the case of the horseback riding pose. The back waistline of the riding breeches should be raised compared to the front waistline; subsequently, an increased waistline angle results in less back waistline decrease. The breeches have plenty of length from back waist to crotch so the breech fit can be improved. The thigh circumference increased when riding in the front; therefore, good elasticity of the weft direction of the fabric is recommended. The length increase and the peripheral increase of the front knee significantly increased the surface area of the knee; consequently, knee patch material should be a two-way elastic fabric in all directions to enhance comfort according to riding motion.

Comparison of Avatar Posture Formation According to 3D Virtual Garment Modeling Programs -Focusing on Cycling Movements of High-School Male Cyclist-

  • Park, Hyunjeong;Do, Wolhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.965-977
    • /
    • 2021
  • The study aimed to analyze the functional differences in 3D virtual garment programs and compare body scan data with the corresponding 3D virtual models. We selected 3D virtual garment programs, formed virtual models in a representative size for high-school male cyclists, and analyzed them using the Design-X program. The results were as follows. In the 3D virtual garment programs, the anthropometric items for virtual model forming differed significantly from the standard anthropometric items suggested by Size Korea. Comparing the lower body scan data and virtual models formed by the 3D virtual garment programs, the biggest difference was in the shapes of the waist and hips, i.e., the flatness values of the waist and hips were different for each program in the cross-section view. In the lower body, a data-input-based program was needed for changing the exact measurement position of the waist circumference and hips' shape in detail. If a 3D virtual garment program provides functions for the virtual model's joint angle input and free motion transformation, it is expected to be widely used in the sportswear industry.

Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET (13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가)

  • Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.20-23
    • /
    • 2016
  • Purpose Because of heart movement, PET image of heart is very blur. So, PET scan gated with ECG is necessary to improve a spatial resolution of heart PET image. In this study, we will evaluate a image quality of both gated $^{13}N-ammonia$ PET scan and non-gated one. Materials and Methods Before start a heart PET, we attached a ECG electrode on patients (n = 5, $aged=54{\pm}17$). And we started a list mode PET scan that used by a mCT40 PET/CT (siemens, germany) during 10 minute, injected $^{13}N-ammonia$ ($378{\pm}50MBq$) to a patients at same time. By using this list mode data, we reconstructed both gated PET image and non-gated PET image. Then we analysed a profiles of those images, performed a blind test, and subtracted a gated image on non-gated image. Results FWHM of a gated image is improved about 23% and there is a differency count distribution at a subtracted image from non-gated image to a gated image. But in case of blind test, everybody select the gated image as a better quality among each images. Conclusion As a result, we can find that image quality will improve by using gated PET scan. In additional, we can calculate a EF valve, apply QGS, QPS of PET. Therefore, the gated PET scan help improving an accuracy, applying a more information for a diagnosis.

  • PDF