• Title/Summary/Keyword: Scan motion

Search Result 159, Processing Time 0.025 seconds

3D Body Scan Data Analysis for the Slim-fit Dress Shirts Pattern Design -Focused on the 40s Male- (슬림 핏(Slim-fit) 드레스 셔츠 패턴 설계를 위한 3D Body Scan Data 활용에 관한 연구 -40대 남성을 중심으로-)

  • Shin, Kyounghee;Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.1
    • /
    • pp.97-109
    • /
    • 2014
  • This study developed a functional dress shirt for adult males that reflected the body surface variation of a human body section by motion. This study conducted a 3D body scan for 8 subjects in their 40's based on the Size Korea 2010 database. Data recorded the proper posture change value and body surface change value to develop functional dress shirts for adult males. We scanned the subjects with a 3D body scanner for five primarily male wearing dress shirts and operating postures, right standing, arms raised to $90^{\circ}$ horizontal forward position, arms raised $90^{\circ}$ to the horizontal position side, lift up the arm $180^{\circ}$, and arm forward $90^{\circ}$ in a bent posture. We analyzed the 3D scan data from those motions to examine change of length using 3D software Rapidform XOS. The results indicated that the body surface sections with contraction were the front and rear shoulder area, armpit and central length as well the width of arms at more than 10%. The increased body section included the body and armpit back length; in addition, the rear arm vibration girth and under arm girth were more than 10%. In order to reflect the size variation of for each motion, the ease amount of the front and rear shoulder length and width needs to be reduced 20% because it affects the shoulder length during the right standing. The results suggest that the ease amount of the shoulder length should be minimal. The ease amount of the back size needs to be 0.5-2cm bigger and set 0.5-1.5cm longer than the dress shirt length side drooping to compensate for the side length shortage of each motion. The sleeve length needs to be 0-0.5cm shorter, and ease amount of the girth of sleeve bottom needs to be reduced 0-0.7cm due to the size variation of arms. However, the girth of the rear arms is suggested to be 0-0.6cm longer in the ease amount to the rear arm girth as the extension is more than 10% over the width and length of each motion.

Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study (자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구)

  • Kim, Nam Young;Kim, Ju Hui;Lim, Jun;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • Recently, magnetic resonance imaging (MRI), which can acquire images with good contrast without exposure to radiation, has been widely used for diagnosis. However, noise that reduces the accuracy of diagnosis is essentially generated when acquiring the MR images, and by adjusting the parameters, the noise problem can be solved to obtain an image with excellent characteristics. Among the parameters, the number of excitation (NEX) can acquire images with excellent characteristics without additional degradation of image characteristics. In contrast, appropriate NEX setting is required since the scan time increases and motion artifacts may occur. Therefore, in this study, after fixing all MRI parameters through the MRiLab simulation program, we tried to evaluate the tendency of image characteristics according to changing NEX through quantitative evaluation of brain T2 weighted images acquired by adjusting only NEX. To evaluate the noise level and similarity of the acquired image, signal to noise ratio (SNR), contrast to noise ratio (CNR), root mean square error (RMSE) and peak signal to noise ratio (PSNR) were calculated. As a result, both noise level and similarity evaluation factors showed improved values as NEX increased, while the increasing width gradually decreased. In conclusion, we demonstrated that an appropriate NEX setting is important because an excessively large NEX does not affect image characteristics improvement and cause motion artifacts due to a long scan.

An Efficient Motion Estimation Method which Supports Variable Block Sizes and Multi-frames for H.264 Video Compression (H.264 동영상 압축에서의 가변 블록과 다중 프레임을 지원하는 효율적인 움직임 추정 방법)

  • Yoon, Mi-Sun;Chang, Seung-Ho;Moon, Dong-Sun;Shin, Hyun-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.5
    • /
    • pp.58-65
    • /
    • 2007
  • As multimedia portable devices become popular, the amount of computation for processing data including video compression has significantly increased. Various researches for low power consumption of the mobile devices and real time processing have been reported. Motion Estimation is responsible for 67% of H.264 encoder complexity. In this research, a new circuit is designed for motion estimation. The new circuit uses motion prediction based on approximate SAD, Alternative Row Scan (ARS), DAU, and FDVS algorithms. Our new method can reduce the amount of computation by 75% when compared to multi-frame motion estimation suggested in JM8.2. Furthermore, optimal number and size of reference frame blocks are determined to reduce computation without affecting the PSNR. The proposed Motion Estimation method has been verified by using the hardware and software Co-Simulation with iPROVE. It can process 30 CIF frames/sec at 50MHz.

Visual Measurement of Pile Movement for the Foundation Work using a High-Speed Line-Scan

  • Lim, Mee-Seub;Lim, Joon-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1802-1807
    • /
    • 2004
  • When a construction company builds a high structure, many piles should be driven into the ground by a hammer whose weight is 7,000 Kg in order to make the ground under the structure safe and strong. So, it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously

  • PDF

Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator (Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석)

  • 이문규;김종민;김동민;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.363-367
    • /
    • 2003
  • Contact area and pressure are important factors which directly influence a life of knee implants. Since implant's mechanical functions should be experimentally evaluated for clinical use, many studies using a knee simulator and a pressure sensor system have been conducted. However it has not been reported that the contact pressure's distribution of a knee implant motion was estimated in real-time during a gate cycle. Therefore. the objective of this study was to analyze the contact pressure distribution for the motion of a joint using the knee simulator and I-scan sensor system. For this purpose, we developed a force-controlled dynamic knee simulator to evaluate the mechanical performance of artificial knee joint. This simulator includes a function of a soft tissue and has a 4-degree-of-freedom to represent an axial compressive load and a flexion angle. As axial compressive force and a flexion angle of the femoral component can be controlled by PC program. The pressure is also measured from I-scan system and simulator to visualize the pressure distribution on the joint contact surfaces under loading condition during walking cycle. The compressive loading curve was the major cause for the contact pressure distribution and its center move in a cycle as to a flexion angie. In conclusion, this system can be used to evaluate to the geometric interaction of femoral and tibial design due to a measured mechanical function such as a contact pressure, contact area and a motion of a loading center.

A study of the variations by motion of the Lower body Using 3D Body Surface Scan Data of a man in his early twenties (3차원 스캐너를 이용한 20대 남성의 하반신 신축량 분석)

  • Sohn, Boo-Hyun;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.18 no.3
    • /
    • pp.729-740
    • /
    • 2009
  • This study is to research on the rate of expansion or contraction according to movement of the lower body of the man their twenties using Rapid Form software. And aim of this study is to get information of ease allowance in developing slacks pattern using 3D body surface scan data through comparison with existing slacks patterns. Considering on the contraction and expansion according to movement, it need to set the more ease allowance in hip circumference than waist circumference, and the more ease allowance in back hip width than front hip width in slacks. In crotch length, the length of front crotch is revealed contraction but the length of back crotch is revealed expansion. It is desirable lowering front waist line and raising back waist line to possess ease allowance in back crotch area. The length of side seam is revealed a little expansion but the length of inseam is showed a great expansion. To develop slacks pattern of scientific approach using 3D body surface scan data, it need to analysis the rate of expansion and contraction of the lower body based on the movement, shear deformation, slip in fabrics and skin, or in fabrics and fabrics, and slip down from waist line.

Identification and Assessment of Paradoxical Ventricular Wall Motion Using ECG Gated Blood Pool Scan - Comparison of Cine Loop, Phase Analysis and Paradox Image - (ECG Gated Blood Pool Scan을 이용한 심실벽 역행성 운동의 평가 - Cine Loop, Phase Analysis, Paradox Image의 비교 -)

  • Lee, Jae-Tae;Kim, Gwang-Weon;Jeong, Byeong-Cheon;Lee, Kyu-Bo;Whang, Kee-Suk;Chae, Sung-Chul;Jeon, Jae-Eun;Park, Wee-Hyun;Lee, Hyong-Woo;Chung, Jin-Hong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.244-253
    • /
    • 1990
  • Sixty-four patients with paradoxical ventricular wall motion noticed both in angiocardiography or 2-dimensional echocardiography were assessed by ECG gated blood pool scan (GBPS). Endless cine loop image, phase and amplitude images and paradox image obtained by visual inspection of each cardiac beat or Fourier transformation of acquired raw data were investigated to determine the incremental value of GBPS with these processing methods for identification of paradoxical ventricular wall motion. The results were as follows: 1) Paradoxical wall motions were observed on interventricular septum in 34 cases, left ventricular free wall in 26 and right ventricular wall in 24. Underlying heart diseases were ischemic (23 cases) valvular(9), congenital heart disease (12), cardiomyopathy (5). pericardial effusion(5), post cardiac surgery(3), col pulmonale (2), endocarditis(1) and right ventricular tumor(1). 2) Left ventricular ejection fractions of patients with paradoxical left ventricular wall motion were significantly lower than those with paradoxical septal motion(p<0.005). 3) The sensitivity of each processing methods for detecting paradoxical wall motion was 76.9% by phase analysis, 74.6% by endless cine loop mapping and 68.4% by paradox image manipultion respectively. Paradoxial motions visualized only in phase, paradox or both images were appeared as hypokinesia or akinesia in cine loop image. 4) All events could be identified by at least one of above three processing methods, however only 34 cases (48.4%) showed the paradoxical molies in all of the three images. By these findings, we concluded that simultaneous inspection of all above three processing methods-endless cine loop, phase analysis and paradox image-is necessary for accurate identification and assessment of paradoxical ventricular wall motion when performing GBPS.

  • PDF

Fast Motion Estimation Algorithms Through Adaptive Application of the Hadamard Transform (하다마드 변환의 적응적 적용을 이용한 고속 움직임 예측 알고리즘)

  • Lee, Hyuk;Kim, Jong-Ho;Jin, Soon-Jong;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.8C
    • /
    • pp.712-719
    • /
    • 2007
  • In this paper, we propose a new, effective, fast motion estimation algorithms using $4{\times}4$ pixels Hadamard transform. The Hadamard transform has the advantage of simplicity because it uses only addition and subtraction. Motion estimation is composed of three stages. First, it should be decided whether to terminate the search early and use a previous motion vector with DC(Direct Current) coefficients. Then the adaptive matching scan order for motion estimation should be determined according to the image complexity using AC(Alternating Current) coefficients. Experimentally, we adapted this algorithms to MVFAST and PMVFAST algorithms, and the proposed algorithms turn out to be very efficient in terms of computational speed while remaining almost the same in terms of PSNR(Peak Signal-to-Noise Ratio) compared to MVFAST and PMVFAST algorithms.

The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가)

  • Lee, Dong-Hun;Yoo, Hee-Jae;Lee, Jong-Hun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

Design of the Step-stare Image Gathering System for an Aerial Reconnaissance (항공 정찰용 Step-stare 영상획득 시스템 설계)

  • Baek, Woonhyuk;Park, Jaeyoung;Ahn, Junghun;Lee, Jungsuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.813-820
    • /
    • 2014
  • This paper presents design and performance validation of a method for motion compensation using fast steering mirror. First of all, the schematics of the Electro Optical/Infra-Red (EO/IR) and step-stare image gathering system for an aerial reconnaissance are introduced. Because of the steering mirror with low inertia so called Back scan mechanism (BSM), the fast step-stare image gathering technique that is required for taking a high-definition still image will be realized. After then, the BSM hardware includes motors and feedback sensors are introduced. Also, the motion profile for BSM will be designed to compensate roll scan motion of the gimbals. At the end of this paper, designed profile and tracking performance of the EO/IR system with BSM will be validated through experiments.