• Title/Summary/Keyword: Scan motion

Search Result 159, Processing Time 0.027 seconds

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF

DCT Coefficient Block Size Classification for Image Coding (영상 부호화를 위한 DCT 계수 블럭 크기 분류)

  • Gang, Gyeong-In;Kim, Jeong-Il;Jeong, Geun-Won;Lee, Gwang-Bae;Kim, Hyeon-Uk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.3
    • /
    • pp.880-894
    • /
    • 1997
  • In this paper,we propose a new algorithm to perform DCT(Discrete Cosine Transform) withn the area reduced by prdeicting position of quantization coefficients to be zero.This proposed algorithm not only decreases the enoding time and the decoding time by reducing computation amount of FDCT(Forward DCT)and IDCT(Inverse DCT) but also increases comprossion ratio by performing each diffirent horizontal- vereical zig-zag scan assording to the calssified block size for each block on the huffiman coeing.Traditional image coding method performs the samd DCT computation and zig-zag scan over all blocks,however this proposed algorthm reduces FDCT computation time by setting to zero insted of computing DCT for quantization codfficients outside classfified block size on the encoding.Also,the algorithm reduces IDCT computation the by performing IDCT for only dequantization coefficients within calssified block size on the decoding.In addition, the algorithm reduces Run-Length by carrying out horizontal-vertical zig-zag scan approriate to the slassified block chraateristics,thus providing the improverment of the compression ratio,On the on ther hand,this proposed algorithm can be applied to 16*16 block processing in which the compression ratio and the image resolution are optimal but the encoding time and the decoding time take long.Also,the algorithm can be extended to motion image coding requirng real time processing.

  • PDF

Virtual Reality for Dental Implant Surgical Education (가상현실을 이용한 치과 임플란트 수술 교육)

  • Moon, Seong-Yong;Choi, Bong-Du;Moon, Young-Lae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.169-174
    • /
    • 2016
  • In this study, we evaluated the virtual reality model for dental implant surgery and discussed about the method to make the surgical environment for virtual reality with practical patient data. The anatomical model for patient face was fabricated by facial and oral scan data based on CT data. The simulation scenario was composed step by step fashion with Unity3D. From incision and sinus bone graft procedure which is needed to this patient model to implant installation and bone graft was included in this scenario. We used the HMD and leap motion for immersiveness and feeling of real operation. Twenty training doctor was attended this simulation study, and surveyed their satisfactory results by questionnaire. Implant surgery education program was showed the possibilities of educational tool for dental students and training doctors. Virtual reality for surgical education with HMD and leap motion had advantages, in terms of cheap prcie, easy access.

Effective Motor Evoked Potential Waveforms in Patients with Lower Extremity Weakness (다리에 힘이 없는 환자에서 효과적인 운동 유발전위 파형 측정에 대한 고찰)

  • Lim, Sung-Hyuk;Park, Sang-Ku;Han, Hung-Tae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.1
    • /
    • pp.41-48
    • /
    • 2016
  • Motor evoked potential of spinal surgery is known to cause damage due to the movement path of the continuous scan operation and surgery can be performed with minimized disability after surgery. However, if it is not at all formed at the wave motion evoked potential can occur during surgery and, in some cases the size of the waveform to be measured is very small and intermittent. In this case, the surgery cannot provide information about whether there is neurological damage. Increased intensity of the wave-induced motion of the dislocation does not occur if it appears in a very small amplitude stimulus, but changing the inspection area that electrical stimulation of the waveform changes could not be found. However, stimulation of a wide area in the cerebral cortex was found to occur with a waveform in the patients who underwent examination. Through this study, we propose a useful motor evoked potential test. From November to December 2015 three spine surgery patients visited Samsung Medical Center as neurosurgery patients with omission discomfort, gait disturbance, and no symptom of strength before surgery. In spine surgery patients with motor grade weakness, when motor evoked potential waveform has not been measured, in examination of the site of electrical stimulation of the cerebral cortex from entering the C3+C5/C4+C6 or C3+C1/C4+C2 if by the activity of more motor neuron unit, it was found that the waveform is better formed.

Use of an Ultrasonic Osteotome for Direct Removal of Beak-Type Ossification of Posterior Longitudinal Ligament in the Thoracic Spine

  • Kim, Chi Heon;Renaldo, Nicholas;Chung, Chun Kee;Lee, Heui Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.571-577
    • /
    • 2015
  • Direct removal of beak-type ossification of posterior longitudinal ligament at thoracic spine (T-OPLL) is a challenging surgical technique due to the potential risk of neural injury. Slipping off the cutting surface of a high-speed drill may result in entrapment in neural structures, leading to serious complications. Removal of T-OPLL with an ultrasonic osteotome, utilizing back and forth micro-motion of a blade rather than rotatory-motion of drill, may reduce such complications. We have applied the ultrasonic osteotome for posterior circumferential decompression of T-OPLL for three consecutive patients with beak-type OPLL and have described the surgical techniques and patient outcomes. The preoperative chief complaint was gait disturbance in all patients. Japanese orthopedic association scores (JOA) was used for functional assessment. Scores measured 2/11, 5/11, 2/11, and 4/11 for each patient. The ventral T-OPLL mass was exposed after posterior midline approach, laminotomy and transeversectomy. The T-OPLL mass was directly removed with an ultrasonic osteotome and instrumented segmental fixation was performed. The surgeries were uneventful. Detailed surgical techniques were presented. Gait disturbance was improved in all patients. Dural tear occurred in one patient without squeal. Postoperative JOA was 6/11, 10/11, 8/11, and 8/11 (recovery rate; 44%, 83%, 67%, and 43%) respectively at 18, 18, 10, and 1 months postoperative. T-OPLL was completely removed in all patients as confirmed with computed tomography scan. We hope that surgical difficulties in direct removal of T-OPLL might be reduced by utilizing ultrasonic osteotome.

Gesture-based Table Tennis Game in AR Environment (증강현실과 제스처를 이용한 비전기반 탁구 게임)

  • Yang, Jong-Yeol;Lee, Sang-Kyung;Kyoung, Dong-Wuk;Jung, Kee-Chul
    • Journal of Korea Game Society
    • /
    • v.5 no.3
    • /
    • pp.3-10
    • /
    • 2005
  • We present the computer table tennis game using player's swing motion. We need to transform a real world coordinate into a virtual world coordinate in order to hit the virtual ball. We can not get a correct 3-dimension position of racket in environment that using one camera or simple image processing. Therefore we use Augmented Reality (AR) concept to develop the game. This paper shows the AR table tennis game using gesture and method to develop the 3D interaction game that only using one camera without any motion detection device or stereo cameras. Also, we use a scan line method to recognize gesture for speedy processing. The game is developed using ARtoolkit and DirectX that is popular tool of SDK for game development.

  • PDF

Saptio-temporal Deinterlacing Based on Edge Direction and Spatio-temporal Brightness Variations (에지 방향성과 시공간 밝기 변화율을 고려한 시공간 De-Interlacing)

  • Jung, Jee-Hoon;Hong, Sung-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.16 no.5
    • /
    • pp.873-882
    • /
    • 2011
  • In this paper, we propose an efficient deinterlacing algorithm which interpolates the missing scan lines by weighted summing of the intra and the inter interpolation pixels according to the spatio-temporal variation. In the spatial interpolation, we adopt a new edge based spatial interpolation method which includes edge directional refinement. The conventional edge dependent interpolation algorithms are very sensitive to noise due to the failure of estimating edge direction. In order to exactly detect edge direction, our method first finds the edge directions around the pixel to be interpolated and then refines edge direction of the pixel using weighted maximun frequent filter. Futhermore, we improve the accuracy of motion detection by reducing the possibility of motion detection error using 3 tab median filter. In the final interpolation step, we adopt weighted sum of intra and inter interpolation pixels according to spatio-temporal variation ratio, thereby improving the quality in slow moving area. Simulation results show the efficacy of the proposed method with significant improvement over the previous methods in terms of the objective PSNR quality as well as the subjective image quality.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF