• Title/Summary/Keyword: Scan Testing

Search Result 228, Processing Time 0.022 seconds

A Study on a Crack Evaluation Technique for Turbine Blade Root Using Phased Array Ultrasonics (위상배열 초음파를 이용한 터빈 블레이드 루트부내 결함평가 기법 연구)

  • Cho, Yong-Sang;Jung, Gye-Jo;Park, Sang-Ki;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.151-157
    • /
    • 2004
  • Ultrasonic testing is a kind of nondestructive test to detect a crack or discontinuity in materials or on material surfaces by sending ultrasound to it. This conventional ultrasonic technique has some limitations in reliably detecting crack or accurately assessing materials in the case of complex-shaped power plant components such as a turbine blade root. An alternative method for such a difficult inspection is highly needed. In this study, application of a phased array ultrasonic testing (UT) system to a turbine blade, one of the critical power plant components, has been considered, and the particular incident angle has been determined so that the greatest track detectability and the most accurate crack length evaluation nay be achieved. The response of ultrasonic phased array was also analyzed to establish a special method to determine the track )ength without moving the transducer. The result showed that the developed method for crack length assessment is a more accurate and effective method, compared with the conventional method.

Method to Evaluate Fabric Contamination Due to Fine Dust (섬유소재의 미세먼지 오염도 평가 방법 개발에 관한 연구)

  • Hwang, So-Young;Kwon, Jin-Kyung;Kim, Young-Sil;Choi, Eun-Jin;Kim, Da-Jin;Kim, Min;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.86-91
    • /
    • 2021
  • Recently, functional clothes that can reduce deposition and/or penetration of fine dust have been developed. However, there are no methods to quantitatively evaluate the performance of these clothes. In this study, we developed a method to contaminate a fabric using fine dust and established an approach to quantitatively assess the degree of particle contamination on the fabric surface. Silicate powder was chosen as the particle to simulate fine dust because silicate particles are fluorescent under UV light; therefore, they can be distinguished from any color of non-fluorescent fabric surface. A camera with a high-resolution lens system was used to scan the surface of the contaminated fabric surface, and the degree of particle contamination of the fabric surface was analyzed in terms of the pixels corresponding to the area of the fabric surface contaminated by silicate particles. Finished or unfinished nylon fabrics as well as cotton fabrics were contaminated with silicate particles, and their surfaces were scanned using the established camera. The proposed assessment method was found to be useful for quantitatively comparing the degree of particle contamination of the fabrics.

A Measure for Improvement in Accuracy by Performance Evaluation of a DPRMs (말뚝 변위 측정시스템의 진동 평가에 의한 정확도 향상 대책)

  • Choi Youngsam;Chung Jintai;Lee Kyeyoung;Han Changsoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1653-1659
    • /
    • 2005
  • In this study, the performance of a DPRMs is evaluated and the measurement precision for the pile driving is presented. The DPRMs is a visual-measurement system for the pile rebound and the penetration movement using a high speed line-scan camera. The DPRMs generates the measurement deviation. It is caused by the strong impact for the pile driving. To reduce it, the vibration signal analysis about the pile driving is performed. As a result, it is confirmed that the tilting frequency of a camera-tripod structure corresponding to excitation frequency range of the ground is under 40Hz. Through the structure modification, the camera-tripod structure is redesigned to the model being free itself from the excitation frequency range of the ground. By the verification testing about the improvement effects, it is inspected that the tilting and measurement deviation of the redesigned DPRMs are reduced.

Quality Characteristics of Bread Added with Turmeric Powder (울금 분말을 첨가한 식빵의 품질 특성)

  • Jeon, Tae-Geon;An, Hye-Lyung;Lee, Kwang-Suck
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.20 no.1
    • /
    • pp.113-121
    • /
    • 2010
  • Recently, there has been a great deal of public interest in health foods, such as turmeric (Curcuma longa L). In this study, the baking features of turmeric powder were evaluated by making pan bread. To accomplish this, the effects of added turmeric powder on the results of mixograph analysis as well as, the pH and, fermentation rate were measured. In addition, the features of the bread were examined by testing the stickiness of the dough and the TPA of the product using a texture analyzer. Finally, the consumer's preferences were investigated by evaluation of the color difference, crumbScan and sensory evaluation. The results revealed that as the level of turmeric powder increased, the pH decreased. which resulted in the gas possessing capacity of the dough improving and the fermentation persistence of the dough increasing. In addition, the stickiness increased as the turmeric powder content increased. However, there were significant differences among breads produced using different amounts of turmeric powder. Evaluation of the taste revealed that the TP3 group had the higher score than control score and TP7 had the lowest score. In overall preference, TP7 was especially low and the preference decreased as the content of turmeric powder increased.

An Efficient Technique to Improve Compression for Low-Power Scan Test Data (저전력 테스트 데이터 압축 개선을 위한 효과적인 기법)

  • Song, Jae-Hoon;Kim, Doo-Young;Kim, Ki-Tae;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.104-110
    • /
    • 2006
  • The huge test data volume, test time and power consumption are major problems in system-on-a-chip testing. To tackle those problems, we propose a new test data compression technique. Initially, don't-cares in a pre-computed test cube set are assigned to reduce the test power consumption, and then, the fully specified low-power test data is transformed to improve compression efficiency by neighboring bit-wise exclusive-or (NB-XOR) scheme. Finally, the transformed test set is compressed to reduce both the test equipment storage requirements and test application time.

A New Test Algorithm for Effective Interconnect Testing Among SoC IPs (SoC IP 간의 효과적인 연결 테스트를 위한 알고리듬 개발)

  • 김용준;강성호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.1
    • /
    • pp.61-71
    • /
    • 2003
  • Interconnect test for highly integrated environments like SoC, becomes more important as the complexity of a circuit increases. This importance is from two facts, test time and complete diagnosis. Since the interconnect test between IPs is based on the scan technology such as IEEE1149.1 and IEEE P1500, it takes long test time to apply test vectors serially through a long scan chain. Complete diagnosis is another important issue because a defect on interconnects are shown as a defect on a chip. But generally, interconnect test algorithms that need the short test time can not do complete diagnosis and algorithms that perform complete diagnosis need long test time. A new interconnect test algorithm is developed. The new algorithm can provide a complete diagnosis for all faults with shorter test length compared to the previous algorithms.

Development of Simulated signal generator for Small Millimeter-wave Tracking Radar (소형 밀리미터파 추적 레이다용 모의신호 발생장치 개발)

  • Kim, Hong-Rak;Park, Seung-Wook;Woo, Seon-Keol;Kim, Youn-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.157-163
    • /
    • 2019
  • A small millimeter-wave tracking radar is a pulse radar that searches, detects, and tracks a target in real time through a TWS (Track While Scan) method on a sea-going traps target with a large RCS running at low speed. This paper describes the development of a simulated signal generator to verify the performance of a small millimeter wave tracking radar in laboratory anechoic chamber environment. We describe a GUI program for testing and performance analysis in conjunction with hardware configuration and tracking radar, and verified the simulated signal generator implemented through performance test.

Probability Analysis for Impact Behavior of Composite Laminates Subjected to Low-Velocity Impact (저속충격을 받는 복합적층판의 충격거동에 대한 확률분포 특성)

  • Ha, Seung-Chul;Kim, In-Gul;Lee, Seok-Je;Cho, Sang-Gyu;Jang, Moon-Ho;Choi, Ik-Hyeon
    • Composites Research
    • /
    • v.22 no.6
    • /
    • pp.18-22
    • /
    • 2009
  • In this paper, we examined impact force and impact behavior through low velocity impact tests of composite laminates. And through c-scan as nondestructive inspection, explored the damaged area being difficult to examine with the visual inspection. Through CAI tests, we also measured the compression strength of composite laminates subjected to low velocity impact. To examine the characteristics of impact behavior measured from low velocity impact test, nondestructive inspection, and CAI test, the simulated data are generated from the test data using Monte-Carlo simulation, then represented it by probability distribution. The testing results using visible stochastic distribution were examined and compared.

Detection of Small Flaws in SiC Structural Ceramic in High Frequency Detection Field (고주파수 초음파 검출장에서 SiC 세라믹 내부의 미세결함 검출)

  • Kim, Byoung-Geuk;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.2
    • /
    • pp.100-107
    • /
    • 1997
  • It has been required to find flaws smaller than $100{\mu}m$ by fracture mechanic consideration. We prepared the infiltrated and sintered SiC structural ceramic specimens including artificial flaws, Fe, pore, WC, Si particles of size ranging from $36{\mu}m$ to $200{\mu}m$. We performed C-scan for the specimen using a high frequency and broad-band ultrasonic transducer to employ polyvinylidene fluoride(PVDF) and a broad-band electric scanning system. The flaws in the ceramic specimens were detected in the high frequency detection field up to 100MHz. But, the flaws were not detected in lower frequency detection field up to 60MHz. The ratio of the detected smallest flaw size to the wavelength calculated at the center frequency, 80MHz, was about 0.25 in Rayleigh scattering region.

  • PDF

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF