• 제목/요약/키워드: Scan Model

검색결과 472건 처리시간 0.024초

StereoLithography로 3차원 형상가공을 위한 레이저 조사경로 생성에 관한 연구 (A study on laser scan path generation for manufacturing 3-dimensional body using StereoLithography)

  • 안대건;김준안;이석희;백인환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.687-692
    • /
    • 1993
  • This paper deals with the generation of laser scan path for manufacturing 3-dimensional body using StereoLithography. The purpose of this study is to develop one module of the StersoLithography system(SLA) for Rapid Protyping and Manufacturing. AutoCAD system is used to supply CAD information from model. The X-Y controller which was made for a special purpose is used to test this system. The system software developed is composed of 3 main modules, the first module is calculating the boundary point os laser scan path. The scound module is generating final output file which is used to down load on the controller. The result of this study shows a good algorithm to generate laser scan path on the basis of simple mathematical background.

  • PDF

A-Scan 초음파 신호의 시간분해능 향상을 위한 웨이브렛 해석 기반 디컨벌루션 기법 (Wavelet Transform Based Deconvolution for Improvement of Time-Resolution of A-Scan Ultrasonic Signal)

  • 하욥;장경영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.84-89
    • /
    • 2001
  • Ultrasonic pulse echo method comes to be difficult to apply to the multi-layered structure with very thin layer, because the echoes from the top and the bottom of the layer are overlapped. Conventionally method, deconvolution technique has been used for the decomposition of overlapped UT signals, however it has disabilities when the waveform of the transmitted signal is distorted according to the propagation. In this paper, the wavelet transform based deconvolution (WTBD) technique is proposed as a new signal processing method that can decompose the overlapped echo signals in A-Scan signal with superior performances compared to the conventional deconvolution technique. Performances of the proposed method are shown by through computer simulations using model signal with noise and are demonstrated by through experiments for the fabricated acryl rod with a thin steel plate bonded to it.

  • PDF

경계면 스캔 기저 구조를 위한 지연시험 (Delay Test for Boundary-Scan based Architectures)

  • 강병욱;안광선
    • 전자공학회논문지A
    • /
    • 제31A권6호
    • /
    • pp.199-208
    • /
    • 1994
  • This paper proposes a delay fault test technique for ICs and PCBs with the boundary-scan architectures supporting ANSI/IEEE Std 1149.1-1990. The hybrid delay fault model, which comprises both of gate delay faults and path delay faults, is selected. We developed a procedure for testing delay faults in the circuits with typical boundary scan cells supporting the standard. Analyzing it,we concluded that it is impractical because the test clock must be 2.5 times faster than the system clock with the cell architect-ures following up the state transition of the TAP controller and test instruction set. We modified the boundary-scan cell and developed test instructions and the test procedure. The modified cell and the procedure need test clock two times slower than the system clock and support the ANSI/IEEE standard perfectly. A 4-bit ALU is selected for the circuits under test. and delay tests are simulated by the SILOS simulator. The simulation results ascertain the accurate operation and effectiveeness of the modified mechanism.

  • PDF

디지털 고령 인체 모델 구축 Part I : 표준 Anthropometry 및 내외형상 (Digital Elderly Human Body Modeling Part I : Standard Anthropometry and Exterior/Interior Geometries)

  • 한지원;최형연;윤경한;박요한
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.96-104
    • /
    • 2009
  • An anatomically detailed elderly human body model is under development. Using the anthropometric database of domestic nation-wide size survey, SizeKorea, a standard size and shape of 50th %tile elderly was constructed. Through the local recruitment process, a male volunteer with 71 years of age, 163cm of height and 63kg of weight has been selected. The exterior (skin) and interior (skeleton and organ) geometries were acquired from whole body 3D laser scan and various medical images such as CT, X-ray, and Ultrasonic of the volunteer. A particular attention has been paid into the combining process of exterior and interior geometries especially for joint articulation positions since they were measured at different postures (sitting vs. supine). A whole ribcage of PMHS which possessed similar anthropometry and age of standard 50th %tile elderly was prepared and dissected for the precise gauge of cortical rib bone thickness distributions. After completing the morphological construction of elderly human body, the finite element modeling will be processed by meshing elements and assigning mechanical properties to various biological tissues which reflect the aging effect.

Comparison of Avatar Posture Formation According to 3D Virtual Garment Modeling Programs -Focusing on Cycling Movements of High-School Male Cyclist-

  • Park, Hyunjeong;Do, Wolhee
    • 한국의류학회지
    • /
    • 제45권6호
    • /
    • pp.965-977
    • /
    • 2021
  • The study aimed to analyze the functional differences in 3D virtual garment programs and compare body scan data with the corresponding 3D virtual models. We selected 3D virtual garment programs, formed virtual models in a representative size for high-school male cyclists, and analyzed them using the Design-X program. The results were as follows. In the 3D virtual garment programs, the anthropometric items for virtual model forming differed significantly from the standard anthropometric items suggested by Size Korea. Comparing the lower body scan data and virtual models formed by the 3D virtual garment programs, the biggest difference was in the shapes of the waist and hips, i.e., the flatness values of the waist and hips were different for each program in the cross-section view. In the lower body, a data-input-based program was needed for changing the exact measurement position of the waist circumference and hips' shape in detail. If a 3D virtual garment program provides functions for the virtual model's joint angle input and free motion transformation, it is expected to be widely used in the sportswear industry.

Fast Spectral Inversion of the Strong Absorption Lines in the Solar Chromosphere Based on a Deep Learning Model

  • Lee, Kyoung-Sun;Chae, Jongchul;Park, Eunsu;Moon, Yong-Jae;Kwak, Hannah;Cho, Kyuhyun
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.46.3-47
    • /
    • 2021
  • Recently a multilayer spectral inversion (MLSI) model has been proposed to infer the physical parameters of plasmas in the solar chromosphere. The inversion solves a three-layer radiative transfer model using the strong absorption line profiles, H alpha and Ca II 8542 Å, taken by the Fast Imaging Solar Spectrograph (FISS). The model successfully provides the physical plasma parameters, such as source functions, Doppler velocities, and Doppler widths in the layers of the photosphere to the chromosphere. However, it is quite expensive to apply the MLSI to a huge number of line profiles. For example, the calculating time is an hour to several hours depending on the size of the scan raster. We apply deep neural network (DNN) to the inversion code to reduce the cost of calculating the physical parameters. We train the models using pairs of absorption line profiles from FISS and their 13 physical parameters (source functions, Doppler velocities, Doppler widths in the chromosphere, and the pre-determined parameters for the photosphere) calculated from the spectral inversion code for 49 scan rasters (~2,000,000 dataset) including quiet and active regions. We use fully connected dense layers for training the model. In addition, we utilize a skip connection to avoid a problem of vanishing gradients. We evaluate the model by comparing the pairs of absorption line profiles and their inverted physical parameters from other quiet and active regions. Our result shows that the deep learning model successfully reproduces physical parameter maps of a scan raster observation per second within 15% of mean absolute percentage error and the mean squared error of 0.3 to 0.003 depending on the parameters. Taking this advantage of high performance of the deep learning model, we plan to provide the physical parameter maps from the FISS observations to understand the chromospheric plasma conditions in various solar features.

  • PDF

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

CNN 기반 전이학습을 이용한 뼈 전이가 존재하는 뼈 스캔 영상 분류 (Classification of Whole Body Bone Scan Image with Bone Metastasis using CNN-based Transfer Learning)

  • 임지영;도탄콩;김수형;이귀상;이민희;민정준;범희승;김현식;강세령;양형정
    • 한국멀티미디어학회논문지
    • /
    • 제25권8호
    • /
    • pp.1224-1232
    • /
    • 2022
  • Whole body bone scan is the most frequently performed nuclear medicine imaging to evaluate bone metastasis in cancer patients. We evaluated the performance of a VGG16-based transfer learning classifier for bone scan images in which metastatic bone lesion was present. A total of 1,000 bone scans in 1,000 cancer patients (500 patients with bone metastasis, 500 patients without bone metastasis) were evaluated. Bone scans were labeled with abnormal/normal for bone metastasis using medical reports and image review. Subsequently, gradient-weighted class activation maps (Grad-CAMs) were generated for explainable AI. The proposed model showed AUROC 0.96 and F1-Score 0.90, indicating that it outperforms to VGG16, ResNet50, Xception, DenseNet121 and InceptionV3. Grad-CAM visualized that the proposed model focuses on hot uptakes, which are indicating active bone lesions, for classification of whole body bone scan images with bone metastases.

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.

A Study on the Automatic Pattern Development of Adult Male Basic Pattern Using 3D Body Scan Data

  • Jeong, Mi-E;Nam, Yun-Ja
    • 패션비즈니스
    • /
    • 제11권3호
    • /
    • pp.35-45
    • /
    • 2007
  • This study examined how to create 2D basic pattern of individuals by means of 3-D body figure, which is to develop a flat of individual basic pattern directly from the 3-D body scan data of each subject using that of the upper body of a male adult. In terms of methodology, this study adopted 3D body scan data on system and body to make examinations in the following steps: 1. Standard point and line were set on human body, along with 3-D definition points(feature points). 2. PB was created by modifying horizontal and longitudinal section of scan data. 3. Ways to set reserve were established in the findings of PB planar development. Respective developed flat patterns were compared with pattern findings in previous studies by means of sensory evaluation. As a result, it was found that both system and body model are basic pattern and belong to appropriate pattern as semi-tight-fit basic pattern with overall appropriate tolerances. Thus, this study came to a conclusion that it is feasible and valid to develop theories for flat development as considered herein.