• Title/Summary/Keyword: Scan Model

Search Result 475, Processing Time 0.027 seconds

Two-degree-of freedom $H_{\infty}$ control of a seeker scan loop using normalized coprime factorization (정규화 소인수분해를 이용한 탐색기 주사루프의 2자유도 $H_{\infty}$ 제어)

  • Lee, H.P.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.102-109
    • /
    • 1997
  • A two-degree-of freedom (TDF) $H_{\infty}$controller for a seeker scan loop is presented for the purpose of improving scanning performances. The perturbed plant model is characterized via the normalized coprime factorization. The TDF $H_{\infty}$controller is designed based on the loop shaping design procedure and model matching approach, and its performances are evaluated and compared with those of a previous work. It is demonstrated that the proposed TDF $H_{\infty}$controller is more effective to the control of the seeker scan loop than the previous controller.oller.

  • PDF

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Design of High-Speed Image Processing System for Line-Scan Camera (라인 스캔 카메라를 위한 고속 영상 처리 시스템 설계)

  • 이운근;백광렬;조석빈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.2
    • /
    • pp.178-184
    • /
    • 2004
  • In this paper, we designed an image processing system for the high speed line-scan camera which adopts the new memory model we proposed. As a resolution and a data rate of the line-scan camera are becoming higher, the faster image processing systems are needed. But many conventional systems are not sufficient to process the image data from the line-scan camera during a very short time. We designed the memory controller which eliminates the time for transferring image data from the line-scan camera to the main memory with high-speed SRAM and has a dual-port configuration therefore the DSP can access the main memory even though the memory controller are writing the image data. The memory controller is implemented by VHDL and Xilinx SPARTAN-IIE FPGA.

A decoupling controller design for the seeker scan loop with a spin-stabilized platform (자전 안정화형 탐색기 주사루프의 비연성 제어기 설계)

  • 유인억;이상정
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.35-41
    • /
    • 1998
  • This paper presents a decoupling controller of the missile seeker scan loop with a spin-stabilized platform. A precise seeker motion with respect to the scan command is essential for the higher acquisition probability of the target. As the seeker scan loop is a deeply cross-coupled two input two output system, an accurate pointing or scanning for each axis to the target is very difficult, even though provided with the help of a high performance controller. When a decoupling control is applied to the seeker scan loop, the cross-coupling between two axes can be reduced to a remarkable amount. As a low order of controller is required for the real time operation, a PI controller with decoupling filter is suggested and compared with other controllers. A linearized dynamic model of seeker scan loop is used and validated through the comparison of experimental results of step responses.

  • PDF

Algorithm for Fabricating 3D Breast Implants by Using MRI and 3D Scan Data (MRI와 3D 스캔 데이터를 이용한 3D 프린팅 유방 인공보형물의 제작 알고리즘)

  • Jeong, Young Jin;Choi, Dong Hun;Kim, Ku-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1385-1395
    • /
    • 2019
  • In this paper, we propose a method to fabricate a patient-specific breast implant using MRI images and 3D scan data. Existing breast implants for breast reconstruction surgery are primarily fabricated products for shaping, and among the limited types of implants, products similar to the patient's breast have been used. In fact, the larger the difference between the shape of the breast and the implant, the more frequent the postoperative side effects and the lower the satisfaction. Previous researches on the fabrication of patient-specific breast implants have used limited information based on only MRI images or on only 3D scan data. In this paper, we propose an algorithm for the fabrication of patient-specific breast implants that combines MRI images with 3D scan data, considering anatomical suitability for external shape, volume, and pectoral muscle. Experimental results show that we can produce precise breast implants using the proposed algorithm.

Anlaysis of Eukaryotic Sequence Pattern using GenScan (GenScan을 이용한 진핵생물의 서열 패턴 분석)

  • Jung, Yong-Gyu;Lim, I-Suel;Cha, Byung-Heun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.113-118
    • /
    • 2011
  • Sequence homology analysis in the substances in the phenomenon of life is to create database by sorting and indexing and to demonstrate the usefulness of informatics. In this paper, Markov models are used in GenScan program to convert the pattern of complex eukaryotic protein sequences. It becomes impossible to navigate the minimum distance, complexity increases exponentially as the exact calculation. It is used scorecard in amino acid substitutions between similar amino acid substitutions to have a differential effect score, and is applied the Markov models sophisticated concealment of the transition probability model. As providing superior method to translate sequences homologous sequences in analysis using blast p, Markov models. is secreted protein structure of sequence translations.

Two Degree of Freedom Robust Controller Design of a Seeker Scan-Loop (탐색기 주사루프의 2자유도 강인제어기 설계)

  • Lee, Ho-Pyeong;Song, Chang-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.157-165
    • /
    • 1995
  • The new formulation of designing the two degree of freedom(TDF) robust controller is proposed using $H_{\infty}$optimization and model matching method. In this formulation the feedback controller and feedforward controller are designed in a single step using $H_{\infty}$optimization procedure. Roughly speaking, the feedback controller is designed to meet robust stability and disturbance rejection specifications, while the feedforward controller is used to improve the robust model matching properties of the closed loop system. The proposed formulation will be illustrated and evaluated on a seeker scan-loop. And the performances of TDF robust controller are compared with those of the $H_{\infty}$ controller designed using Loop Shaping Design Procedure proposed by McFarlane and Glover.lover.

  • PDF

Analysis of the ES detection loss related to the circular scan of radars (레이더의 원형 스캔에 따른 ES 탐지손실 분석)

  • Ryoo, Young-Jin;Kim, Whan-Woo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.159-166
    • /
    • 2005
  • The pulse amplitude of a search radar signal received by an ES system is not constant pulse by pulse because of the radar's scan characteristics. The variation of the pulse amplitude causes the ES detection loss in the ES system. Therefore, the ES detection range equation should consider the ES detection loss caused by the search radar's scan characteristics. In this paper, we theoretically analyze the ES detection loss for the circular scar and propose the model to evaluate it quantitatively. The experiment results for the real search radar signals demonstrate that the proposed model is suitable for the evaluation model of the ES detection loss related to the circular scan of radars.

A Study of Utilizing 2D Photo Scan Technology to Efficiently Design 3D Models (2D 포토 스캔 기술을 활용한 효율적인 3D 모델링 제작방법 연구)

  • Guo, Dawei;Chung, Jeanhun
    • Journal of Digital Convergence
    • /
    • v.15 no.7
    • /
    • pp.393-400
    • /
    • 2017
  • Generally, in special effect video and 3D animation design process, character and background's 3D model is built by 3D program like MAYA or 3DS MAX. But in that manual modeling mode, model design needs much time and costs much money. In this paper, two experimental groups are set to prove use 2D photo scan modeling mode to build 3D model is effective and advanced. The first experimental group is modeling the same object by different experimental setting. The second experimental group is modeling the same background by different experimental setting. Through those two experimental groups, we try to find an effective design method and matters need attention when we use photo scan design mode. We aim to get the model from whole experiment and prove photo scan modeling mode is effective and advanced.

Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner (국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교)

  • Kim, Busob;Kim, Jungho
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.