• Title/Summary/Keyword: Scan Design

검색결과 508건 처리시간 0.028초

3차원 인체의 곡률분포를 이용한 패턴 전개 (Pattern Development using the Curvature Plot of 3D Human Scan Data)

  • 정연희;홍경희
    • 한국의류학회지
    • /
    • 제32권9호
    • /
    • pp.1478-1486
    • /
    • 2008
  • The human body composed of concave and convex curvatures, and the current 3D scanning technology which involves inherent measurement errors make it difficult to extract distinct curvature plot directly. In this study, a method of extracting the clear curvature plot and its application to the cycling pants design were proposed. We have developed the ergonomic pattern from the 3D human body reflecting cycling posture. For the ergonomic design line on the 3D human body, the 3D information on the lower part of four male bodies with flexed posture was analyzed. The 3D scan data of four subjects were obtained using Cyberware. As results, the iteration of the tessellated shell was executed 100 times to obtain optimized curvature plots of the muscles on the body surface, and the boundaries of the curvature plots were applied to the design lines. Maximum(Max-pattern) and mean curvature plots(Mean-pattern) were adopted in the design line of the cycling pants, and performance of those lines was compared with that of conventional princess line(Con-pattern). The average error of total area and length in the 2D pattern developed from the 3D flexed body surface in this study were very minimal($4.58cm^2$(0.19%) and 0.15mm(0.46%)), which was within the range of tolerable limits in clothing production. The pattern obtained from the flexed body reflecting cycling posture already included the contraction and extension of the cycling skin, so that the extra ease for movement and good fit was not need to be considered.

TFT/LCD 시스템 패키지 전기적 특성 분석 및 설계도구의 구현 (Development of a Tool for the Electrical Analysis and Design of TFT/LCD System Package)

  • 임호남;지용
    • 전자공학회논문지A
    • /
    • 제32A권12호
    • /
    • pp.149-158
    • /
    • 1995
  • This paper describes the development of a software tool LCD FRAME that may guide the analyzing process for the electrical characteristics and the design procedure for constructing the thin film transistor liquid crystal display(TFT/LCD) packages. LCD FRAME can analyze its electrical characteristics from the TFT/LCD system package configuration, and provide the design variables to meet the user's requirements. These analysis and design procedure can be done in real time according to the model at simplified package level of TFT/LCD. LCD_FRAME is an object-oriented expert system which considers package elements as objects. With this LCD_FRAME software tool, we analyzed the I-V characteristics of a-Si TFT and its signal distortion which has maximum 1.58 $\mu$s delay along the panel scan line of the package containing 480 ${\times}$ 240 pixels. We designed the package structure of maximum 6.35 $\mu$s signal delays and 3360 ${\times}$ 780 pixels, and as a result we showed that the proper structure of 20 $\mu$m scan line width, 60$\mu$m panel TFT gate width and 8 $\mu$m gate length. This LCD_FRAME software tool provides results of the analysis and the design in the form of input files of the SPICE program, text data files, and graphic charts.

  • PDF

도파관 시뮬레이터를 이용한 광대역 E-평면 넛치 위상 배열 안테나 설계 (The Design of a Wideband E-plane Phased Array Antenna using W/G Simulator)

  • 김준연;소준호;임중수
    • 한국전자파학회논문지
    • /
    • 제14권2호
    • /
    • pp.111-118
    • /
    • 2003
  • 넛치 안테나는 진행파형 안테나로서 공진형 안테나에 비해 광대역 특성과 넓은 빔 폭을 가지므로 광대역 위상 배열 안테나의 복사 소자로 사용되어진다. 본 논문에서는 단일 복사 소자의 해석으로 무한 배열 안테나를 모의할 수 있는 도파관 시뮬레이터를 이용하여 3 : 1 이상의 주파수 대역과 $\pm$45$^{\circ}$의 빔 조향 범위를 만족하는 광대역 E-평면 넛치 위상 배열 안테나를 설계하였다. 설계된 단일 소자의 등가회로 모델링을 통해 단일 소자와 무한 배열소자에서의 임피던스 특성을 비교하였으며, 설계된 결과를 이용하여 1$\times$9배열 E-평면 넛치 위상 배열 안테나 전체를 해석하였다. 이때 구해진 안테나간 상호 결합 계수를 이용하여 각 소자의 빔 조향 각도에 따른 능동 반사 계수를 구하였으며, 능동 소자 패턴을 통해 빔 조향에 따른 이득의 변화를 살펴보았다.

Accuracy of the Point-Based Image Registration Method in Integrating Radiographic and Optical Scan Images: A Pilot Study

  • Mai, Hai Yen;Lee, Du-Hyeong
    • Journal of Korean Dental Science
    • /
    • 제13권1호
    • /
    • pp.28-34
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the influence of different implant computer software on the accuracy of image registration between radiographic and optical scan data. Materials and Methods: Cone-beam computed tomography and optical scan data of a partially edentulous jaw were collected and transferred to three different computer softwares: Blue Sky Plan (Blue Sky Bio), Implant Studio (3M Shape), and Geomagic DesignX (3D systems). In each software, the two image sets were aligned using a point-based automatic image registration algorithm. Image matching error was evaluated by measuring the linear discrepancies between the two images at the anterior and posterior area in the direction of the x-, y-, and z-axes. Kruskal-Wallis test and a post hoc Mann-Whitney U-test with Bonferroni correction were used for statistical analyses. The significance level was set at 0.05. Result: Overall discrepancy values ranged from 0.08 to 0.30 ㎛. The image registration accuracy among the software was significantly different in the x- and z-axes (P=0.009 and <0.001, respectively), but not different in the y-axis (P=0.064). Conclusion: The image registration accuracy performed by a point-based automatic image matching could be different depending on the computer software used.

텔레뷰어 및 코어 스캔 이미지를 이용한 절리면 거칠기 계수의 정량적인 평가 (Quantitative Assessment of Joint Roughness Coefficient from Televiewer and Core scan Images)

  • 김중열;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1205-1210
    • /
    • 2005
  • The behavior of rock mass and solute(e.g. groundwater, radioactivity) flow in fractured rock can be directly influenced by joint roughness. The characteristics of joint roughness is also a main factor for the rock classification(e.g. RMR, Q system) which is usually used in tunnel design. Nevertheless, most of JRC estimation has been carried out only by the examination with the naked eye. This JRC estimation has a lack of objectivity because each investigator judges JRC by his subjective opinion. Therefore, it will be desirable that the assessment of JRC is performed by a numerical analysis which can give a quantitative value corresponding to the characteristics of a roughness curve. Meanwhile, roughness curves for joint surfaces which are observed in drill cores have been obtained only along linear profiles. Although roughness curves are measured in the same joint surface, they can frequently show diverse aspects in a standpoint of roughness characteristics. If roughness curves can be measured along the elliptical circumferences of joint surfaces from core scanning images or Televiewer images, they will certainly be more comprehensive than those measured along linear profiles for roughness characteristics of joint surfaces. This study is focus on dealing with (1) extracting automatically roughness curves from core scan image or Televiewer image, (2) improving the accuracy of quantitative assessment of JRC using fractal dimension concept.

  • PDF

CSG 표현과 경계 표현을 이용한 입체의 설계 및 화면표시 (Design and Display of Solids Using CSG and Boundary Representation)

  • 박기현;경종민
    • 대한전자공학회논문지
    • /
    • 제27권2호
    • /
    • pp.151-157
    • /
    • 1990
  • 본 논문에서는 CSG 방식으로 나타내어진 3차원 입체를 신속하게 외형선 표시방식으로 그려줄 수 있는 방법을 제안한다. 두 개의 CSG 트리가 하나로 결합될때, 각 종속 트리에 해당하는 입체를 구성하는 다각형들간의 교차 부분을 계산하여 주어진 결합 연산자에 따라 합성 입체의 경계선 표현을 얻어내고, 이를 트리의 루트노드에 저장한다. 루트 노드에 저장된 경계선 표현은 입체를 외형선 표시방식으로 그려주는 부분과 다음 경계선 표현 계산에서 사용된다. 자유 곡면을 모델링하기 위하여 Bezier 곡면을 기본 입체의 하나로 취급하였고, 설계된 입체에 대한 실제적인 영상을 얻기 위하여 scan-line 알고리듬을 사용하였는데, 이 방식에서는 각 scan-line을 다각형들이 교차하지 않는 구간들로 나누고, 입체의 CSG 표현을 이용하여 각 구간을 묘화한다.

  • PDF

임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례 (Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report)

  • 신석현;박찬익;강세하;문지은;오민석;박철민;전우진;한성구;김선재;최수진
    • 대한치과보철학회지
    • /
    • 제61권3호
    • /
    • pp.245-256
    • /
    • 2023
  • 임플란트 고정성 보철물 제작 시 디지털 시스템을 이용하여 수복할 때, 3차원적인 임플란트 위치의 구내 스캔과 임시 의치 혹은 임시 보철물 장착 후 구내 스캔을 이용한 이중 디지털 스캐닝(double digital scanning) 기법이 필요하다. 구내 스캔 시, 스캔 바디를 안정적인 랜드마크로 이용하면 다지털 인상의 정확도 향상과 기공과정이 효율적이고 단순화될 수 있다. 본 증례는 완전 디지털 시스템을 활용하여 맞춤형 치과용 임플란트 지대주 및 임시 보철물, 최종 보철물을 계획하고 제작하였다. 임플란트 식립 후, 임플란트에 체결한 구내 스캔 바디와 임시 의치 조직면에 인기 된 구내 스캔 바디의 스캔 영역을 중첩하였다. 중첩된 파일에서 임시 의치의 수직 고경에 맞는 맞춤형 치과용 임플란트 지대주와 임시 보철물을 제작하여 환자에게 시적 하였고, 임시 보철물을 토대로 최종 보철물을 제작하였다. 임시 의치 제작 시 설정한 수직 고경, 중심위 등을 최종 보철물까지 활용하여 기능 및 심미적으로 만족할 만한 결과를 얻어 이를 보고하고자 한다.

슬림 핏(Slim-fit) 드레스 셔츠 패턴 설계를 위한 3D Body Scan Data 활용에 관한 연구 -40대 남성을 중심으로- (3D Body Scan Data Analysis for the Slim-fit Dress Shirts Pattern Design -Focused on the 40s Male-)

  • 신경희;서추연
    • 한국의류학회지
    • /
    • 제38권1호
    • /
    • pp.97-109
    • /
    • 2014
  • This study developed a functional dress shirt for adult males that reflected the body surface variation of a human body section by motion. This study conducted a 3D body scan for 8 subjects in their 40's based on the Size Korea 2010 database. Data recorded the proper posture change value and body surface change value to develop functional dress shirts for adult males. We scanned the subjects with a 3D body scanner for five primarily male wearing dress shirts and operating postures, right standing, arms raised to $90^{\circ}$ horizontal forward position, arms raised $90^{\circ}$ to the horizontal position side, lift up the arm $180^{\circ}$, and arm forward $90^{\circ}$ in a bent posture. We analyzed the 3D scan data from those motions to examine change of length using 3D software Rapidform XOS. The results indicated that the body surface sections with contraction were the front and rear shoulder area, armpit and central length as well the width of arms at more than 10%. The increased body section included the body and armpit back length; in addition, the rear arm vibration girth and under arm girth were more than 10%. In order to reflect the size variation of for each motion, the ease amount of the front and rear shoulder length and width needs to be reduced 20% because it affects the shoulder length during the right standing. The results suggest that the ease amount of the shoulder length should be minimal. The ease amount of the back size needs to be 0.5-2cm bigger and set 0.5-1.5cm longer than the dress shirt length side drooping to compensate for the side length shortage of each motion. The sleeve length needs to be 0-0.5cm shorter, and ease amount of the girth of sleeve bottom needs to be reduced 0-0.7cm due to the size variation of arms. However, the girth of the rear arms is suggested to be 0-0.6cm longer in the ease amount to the rear arm girth as the extension is more than 10% over the width and length of each motion.

디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례 (Digital technique in diagnosis and restoration of maxillary anterior implant: a case report)

  • 방혜민;장우형;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제38권4호
    • /
    • pp.249-256
    • /
    • 2022
  • 성공적인 상악전치부의 임플란트 식립은 많은 고려를 필요로 한다. 환자를 만족시키며 기능적이며 심미적인 보철수복을 위해서는, 치료에 앞서 정확한 진단이 선행되어야 하며 이는 구내스캔, 콘빔시티, 그리고 안면스캔을 중첩함으로 시도해 볼 수 있다. 구내스캔을 통해 얻어지는 환자의 교합양상과 콘빔시티에서 얻어지는 환자의 치조골의 양상 및 질, 그리고 안면스캔에서 얻어지는 환자의 특성과 구외평가를 어우르는 진단은 보다 성공적인 보철수복을 위한 발판이 될 수 있다. 다양한 정보의 중첩을 통해, 보철적으로 이상적인 치관의 위치를 우선순위에 두지만, 환자의 생물학적 한계를 포용하는 "탑다운"형식의 임플란트 진단은, 이를 고려한 서지컬 가이드를 3D 프린팅하고, 수술에 사용함으로써 구현되었다. 환자의 치조골 소실로 인한 임플란트 식립위치의 한계점은, 치아의 선각과 착시효과를 이용한 보철수복을 통하여 극복하려고 노력하였다. 이후, 임시수복물을 사용하고 환자가 가장 편하다고 느끼는 보철물을 장착한 뒤 디지털 교합장비(Arcus Digma II)를 이용하여 전방유도와 하악의 운동을 측정하여 이를 최종보철물에 적용하였다.

거울 및 단일 카메라를 이용한 3차원 발 스캐너 (A 3D Foot Scanner Using Mirrors and Single Camera)

  • 정성엽;박상근
    • 한국CDE학회논문집
    • /
    • 제16권1호
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.