Abstract

Purpose: The purpose of this study was to investigate the influence of different implant computer software on the accuracy of image registration between radiographic and optical scan data. Materials and Methods: Cone-beam computed tomography and optical scan data of a partially edentulous jaw were collected and transferred to three different computer softwares: Blue Sky Plan (Blue Sky Bio), Implant Studio (3M Shape), and Geomagic DesignX (3D systems). In each software, the two image sets were aligned using a point-based automatic image registration algorithm. Image matching error was evaluated by measuring the linear discrepancies between the two images at the anterior and posterior area in the direction of the x-, y-, and z-axes. Kruskal-Wallis test and a post hoc Mann-Whitney U-test with Bonferroni correction were used for statistical analyses. The significance level was set at 0.05. Result: Overall discrepancy values ranged from 0.08 to 0.30 ㎛. The image registration accuracy among the software was significantly different in the x- and z-axes (P=0.009 and <0.001, respectively), but not different in the y-axis (P=0.064). Conclusion: The image registration accuracy performed by a point-based automatic image matching could be different depending on the computer software used.

Keywords

References

  1. Pjetursson BE, Bragger U, Lang NP, Zwahlen M. Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs). Clin Oral Implants Res. 2007; 18(Suppl 3): 97-113. https://doi.org/10.1111/j.1600-0501.2007.01439.x
  2. Noharet R, Pettersson A, Bourgeois D. Accuracy of implant placement in the posterior maxilla as related to 2 types of surgical guides: a pilot study in the human cadaver. J Prosthet Dent. 2014; 112: 526-32. https://doi.org/10.1016/j.prosdent.2013.12.013
  3. Scherer U, Stoetzer M, Ruecker M, Gellrich NC, von See C. Template-guided vs. non-guided drilling in site preparation of dental implants. Clin Oral Investig. 2015; 19: 1339-46. https://doi.org/10.1007/s00784-014-1346-7
  4. Marchack CB. CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient. J Prosthet Dent. 2007; 97: 389-94. https://doi.org/10.1016/S0022-3913(07)60028-6
  5. Park C, Raigrodski AJ, Rosen J, Spiekerman C, London RM. Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study. J Prosthet Dent. 2009; 101: 372-81. https://doi.org/10.1016/S0022-3913(09)60080-9
  6. Garber DA, Belser UC. Restoration-driven implant placement with restoration-generated site development. Compend Contin Educ Dent. 1995; 16: 796, 8-802, 4.
  7. D'Souza KM, Aras MA. Types of implant surgical guides in dentistry: a review. J Oral Implantol. 2012; 38: 643-52. https://doi.org/10.1563/AAID-JOI-D-11-00018
  8. Koop R, Vercruyssen M, Vermeulen K, Quirynen M. Tolerance within the sleeve inserts of different surgical guides for guided implant surgery. Clin Oral Implants Res. 2013; 24: 630-4. https://doi.org/10.1111/j.1600-0501.2012.02436.x
  9. Holst S, Blatz MB, Eitner S. Precision for computerguided implant placement: using 3D planning software and fixed intraoral reference points. J Oral Maxillofac Surg. 2007; 65: 393-9. https://doi.org/10.1016/j.joms.2006.10.050
  10. Ozan O, Turkyilmaz I, Ersoy AE, McGlumphy EA, Rosenstiel SF. Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. J Oral Maxillofac Surg. 2009; 67: 394-401. https://doi.org/10.1016/j.joms.2008.09.033
  11. Raico Gallardo YN, da Silva-Olivio IRT, Mukai E, Morimoto S, Sesma N, Cordaro L. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis. Clin Oral Implants Res. 2017; 28: 602-12. https://doi.org/10.1111/clr.12841
  12. Lee DH, An SY, Hong MH, Jeon KB, Lee KB. Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study. J Adv Prosthodont. 2016; 8: 207-13. https://doi.org/10.4047/jap.2016.8.3.207
  13. Flugge T, Derksen W, Te Poel J, Hassan B, Nelson K, Wismeijer D. Registration of cone beam computed tomography data and intraoral surface scans- a prerequisite for guided implant surgery with CAD/CAM drilling guides. Clin Oral Implants Res. 2017; 28: 1113-8. https://doi.org/10.1111/clr.12925
  14. Mai HN, Kim KR, Lee DH. Non-radiological method for fabrication of a screw-channel drilling guide in cement-retained implant restorations using intraoral digital scanning and imaging superimposition: a clinical report. J Prosthodont. 2017; 26: 88-92. https://doi.org/10.1111/jopr.12469
  15. Almukhtar A, Ju X, Khambay B, McDonald J, Ayoub A. Comparison of the accuracy of voxel based registration and surface based registration for 3D assessment of surgical change following orthognathic surgery. PLoS One. 2014; 9: e93402. https://doi.org/10.1371/journal.pone.0093402
  16. Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol. 2005; 76: 503-7. https://doi.org/10.1902/jop.2005.76.4.503
  17. Baik HS, Kim SY. Facial soft-tissue changes in skeletal Class III orthognathic surgery patients analyzed with 3-dimensional laser scanning. Am J Orthod Dentofacial Orthop. 2010; 138: 167-78. https://doi.org/10.1016/j.ajodo.2010.02.022
  18. Hajeer MY, Ayoub AF, Millett DT. Three-dimensional assessment of facial soft-tissue asymmetry before and after orthognathic surgery. Br J Oral Maxillofac Surg. 2004; 42: 396-404. https://doi.org/10.1016/j.bjoms.2004.05.006
  19. Kim BC, Lee CE, Park W, Kang SH, Zhengguo P, Yi CK, Lee SH. Integration accuracy of digital dental models and 3-dimensional computerized tomography images by sequential point- and surface-based markerless registration. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010; 110: 370-8. https://doi.org/10.1016/j.tripleo.2010.03.036
  20. Swennen GR, Mommaerts MY, Abeloos J, De Clercq C, Lamoral P, Neyt N, Casselman J, Schutyser F. A cone-beam CT based technique to augment the 3D virtual skull model with a detailed dental surface. Int J Oral Maxillofac Surg. 2009; 38: 48-57. https://doi.org/10.1016/j.ijom.2008.11.006
  21. Choi YS, Kim MK, Lee JW, Kang SH. Impact of the number of registration points for replacement of three-dimensional computed tomography images in dental areas using three-dimensional light-scanned images of dental models. Oral Radiol. 2014; 30: 32-7. https://doi.org/10.1007/s11282-013-0136-2
  22. Jamjoom FZ, Yilmaz B, Johnston WM. Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: an in vitro study. Clin Oral Implants Res. 2019; 30: 826-32. https://doi.org/10.1111/clr.13490
  23. DE Vico G, Spinelli D, Bonino M, Schiavetti R, Pozzi A, Ottria L. Computer-assisted virtual treatment planning combined with flapless surgery and immediate loading in the rehabilitation of partial edentulies. Oral Implantol (Rome). 2012; 5: 3-10.
  24. Sonka M, Fitzpatrick JM. Handbook of medical imaging. Bellingham: SPIE Press; 2000. p. 447-506.
  25. Chen J, Li S, Fang S. Quantification of tooth displacement from cone-beam computed tomography images. Am J Orthod Dentofacial Orthop. 2009; 136: 393-400. https://doi.org/10.1016/j.ajodo.2007.10.058
  26. Schulze R, Heil U, Gross D, Bruellmann DD, Dranischnikow E, Schwanecke U, Schoemer E. Artefacts in CBCT: a review. Dentomaxillofac Radiol. 2011; 40: 265-73. https://doi.org/10.1259/dmfr/30642039