• Title/Summary/Keyword: Scaling test

Search Result 430, Processing Time 0.037 seconds

Finite Element Analysis of Electromagnetic Field Equation with Speed E.M.E (속도기전력을 갖는 전자력 방정식의 유한요소 해석)

  • Hahn, Song-Yop
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.4
    • /
    • pp.252-258
    • /
    • 1987
  • Time periodic finite element solutions for sinusoidally excited electromagnetic field problems in moving media are presented. Solutions by the Galerkin method contain spurious oscillations when grid Peclet number is more than one. To suppress these oscillations an upwind finite element method using two different time periodic test functions is introduced. One is multiplied to second and first-order space derivative terma and the other to the time derivative term. Test functions are obtained from trial functions by adding or subtracting quadratic bias functions with appropriate scaling factors. Phase differences are considered between trial functions and bias functions. For simple interpretations of the phase differences, complex scaling factors are used. The proposed method is developed to give nodally exact solutions for uniform grid spacing in one dimensional problems. Based on the one dimensional results, a two dimensional upwinding scheme is also derived.

  • PDF

The Sequential GHT for the Efficient Pattern Recognition (효율적 패턴 인식을 위한 순차적 GHT)

  • 김수환;임승민;이규태;이태원
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.5
    • /
    • pp.327-334
    • /
    • 1991
  • This paper proposes an efficient method of implementing the generalized Hough transform (GHT), which has been hindered by an excessive computing load and a large memory requirement. The conventional algorithm requires a parameter space of 4 dimensions in detection a rotated, scaled, and translated object in an input image. Prior to the application of GHT to the input image, the proposed method determines the angle of rotation and the scaling factor of the test image using the proportion of the edge components between the reference image and test image. With the rotation angle and the scaling factor already determined, the parameter spaceis to be reduced to a simple array of 2 dimensions by applying the unit GHT only one time. The experiments with the image of airplanes reveal that both of the computing time and the requires memory size are reduced by 95 percent, without any degradatationof accuracy, compared with the conventional GHT algorithm.

  • PDF

Validation on the Bodywave Magnitude Estimation of the 2017 DPRK's Nuclear Test by Source Scaling (지진원 상대비율 측정법을 이용한 2017년 북한 핵실험의 실체파 규모 검증)

  • Kim, Tae Sung
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.589-593
    • /
    • 2018
  • Democratic Peoples' Republic of Korea (DPRK) conducted the $6^{th}$ underground nuclear test at the Punggye-ri underground nuclear test site on September 27, 2017 12 hours 30 minutes of Korean local time. Comprehensive Nuclear-Test Ban Treaty Organization (CTBTO) under U.N. announced the body wave magnitude of the event was mb 6.1 while U.S. Geological Survey (USGS)'s calculation was mb 6.3. In this study, the differences of the magnitude estimates were investigated and verified. For this purpose, a source scaling between the $5^{th}$ and $6^{th}$ event, which's epicenters are 200 meters apart, was performed using seismic data sets from 30 broadband stations. The relative amplitude variations of the $6^{th}$ event compared to the $5^{th}$ event in the frequency domain was analyzed through the scaling. The increased amount of the bodywave magnitude $m_b$ for the $6^{th}$ event was calculated at 1 Hz, which was compared to those from USGS and CTBTO's calculations.

Oral health belief and satisfaction after scaling experience with comprehensive dental hygiene care (포괄치위생관리(CDHC) 과정 적용에 따른 스케일링 경험 대상자의 구강건강신념과 만족도)

  • Kim, Mi-Hye;Moon, Sang-Eun;Kim, Yun-Jeong;Kim, Seon-Yeong;Cho, Hye-Eun;Kang, Hyun-Joo
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Objectives: This study was conducted to find scaling patients' oral health belief and satisfaction by applying Comprehensive Dental Hygiene Care (CDHC) process. Methods: From July 1 to September 20, 2020, the data about 182 patients who had scaling in dental clinics and hospitals had been collected and analyzed. For data analysis, SPSS Statistics 22.0 was applied to conduct frequency analysis, chi-square, t-test, One way ANOVA and Pearson's correlation analysis. Results: Regarding oral health behavior, in the CDHC group 92.4% used oral care products (p<0.001), and 67.4% regularly visited dental clinics for oral care (p<0.001). Regarding the oral health belief according to general characteristics, in the CDHC group, persons aged '50-65' scored 2.4 (the highest), and were significantly different from those aged '20-29' as the result of post-hoc analysis (p<0.001). Regarding the oral health belief of the CDHC group according to oral health behavior, the scaling cycle '3 months' scored the highest (p<0.05). The patients' satisfaction had high correlations with benefit (p<0.01) and Importance (p<0.05) as the sub factors of the oral health belief of the CDHC group. Conclusions: CDHC positively influenced scaling patients' oral health belief and satisfaction. Therefore, it is necessary to expand CDHC, as the medium to improve oral health belief and satisfaction, to clinical settings.

Freeze-thaw of Durability for Premixed Fly Ash Concrete (프리믹스 플라이애시 콘크리트 동결-융해 특성)

  • Hong, Seung-Ho;Han, Seung-Hwan;Lee, Byung-Duk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.261-262
    • /
    • 2009
  • The prevent methods of Alkali-Silica Reaction (ASR) are studying after the failure cases by ASR were reported in Korea. In this study, the freeze-thaw test and scaling test for premixed fly ash cement were performed. The ratio of fly ash and cement is 20 percent and 80 percent by weight of total cementious material. The results show that the dynamic modulus after 300 cycles the freeze-thaw test for most of specimen except the specimen have less 3% air was more than 90 % and the loss of weigh the specimen after 50 cycles scaling test was less than 1kg/$m^3$.

  • PDF

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.

Influence of dimensional ratio on collapse characteristics for the thin-walled structures of light weight (경량화용 박육부재의 형상비가 압궤특성에 미치는 영향)

  • 정종안;김정호;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.11-23
    • /
    • 1998
  • In this study, collapse test of thin-walled structure is performed under axially quasi-static and impact load in collapse characteristic to develop the optimum structural member for a light-oriented automobile. Furthermore, the energy-absorbing capacity is observed according to the variety of configuration(circular, square), aspect ratio in aluminum specimen to obtain basic data for the improved member of vehicle. In both quasi-static and impact collapse test, Al circular specimens collapse, in general, with axisymmetric mode in case of thin thickness while collapse with non-axisynmetric mode according to the thickness increase. For Al rectangular specimens, they collapse with axisymmetric mode in case of thin thickness, with mixed collapse mode according to the increase of thickness. In terms of initial max. load, Al square specimen turns out the best member among specimens, and then Al square, circular and circular with large scaling ratio, respectively. In case of quasi-static compression test, the absorbed energy per unit volume and mass shows higher in Al circular specimen, and then Al square, circular with large scaling ratio, respectively, according to shape ratio the absorbed energy per unit volume and mass in case of max. impact compression load is higher than that of static load. But the absorbed energy per unit volume and mass shows that Al circular specimen is the best member. Especially, unlike max. compression loan, the absorbed energy per unit volume and mass in impact test turns out the low value.

  • PDF

Evaluation of steel corrosion and Concrete Freeze-Thaw durability on the Liquid non-chloride deicer (액상 비염화물계 제설제의 강재 부식성 및 콘크리트 동결융해 내구성 평가)

  • Lee, Beung-Duk;Kim, Hyun-Joong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.529-532
    • /
    • 2008
  • Domestic area of most be happened chloride deicer damage. Because daily mean temperature is below 0$^{\circ}C$ from the area of domestic most. Use of deicing chemicals has been and will continue to be a major part of highway snow and ice control methods. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. Extensive use of chloride deicers is, however, not only the source of substantial cost penalties due to their corrosive action and ability to deterioration roadway surface materials but also the source of environmental damages. Particularly, it has been recognized that chlorides present in deicing agents can significantly increase concrete surface scaling. In severe cases, scaling can result in dislodgement of coarse aggregate. This research estimates that pH and test of specific pollutants, dynamic modulus of elasticity for freeze-thaw test of concrete were higher than those NaCl, $CaCl_2$, and NaCl+$CaCl_2$(7:3, w/w), also weight losses for scaling test of concrete were much lower than those of NaCl, $CaCl_2$, and NaCl+$CaCl_2$(7:3, w/w).

  • PDF

Affecting Factors on National Health Insurance Coverage Dental Scaling Experience (건강보험 치석제거 수진에 영향을 미치는 요인)

  • Heo, Yun-Min;Kim, Hyoung-Joo;Kim, Mi-Na;Lim, Hee Jung;Kim, Myoung-Hee;Lim, Do-Seon;Ahn, Yong-Soon
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.287-294
    • /
    • 2015
  • The aim of the study was to investigate the affecting factors on National Health Insurance coverage dental scaling experience. The self-reported survey for the adults living in Seoul, Gyeonggi province and Incheon had been progressed from February 10, 2014, to February 28, 2014, after receiving informed consents. And the 238 survey results had been analysed as the data of this study. The data analysis such as frequency analysis, ${\chi}^2$-test, and multi-logistic regression (p<0.05) for all collected survey data had been processed using IBM SPSS Statistics ver. 20.0. According to multiple logistic regression analysis, regular dental check-up (odds ratio [OR], 2.63; confidence interval [CI], 1.05~6.59) and dental scaling experience (OR, 3.06; CI, 1.09~8.54), monthly income (OR, 3.55; CI, 1.01~12.56) were the factors having statistically significant influence. Therefore, in order to increase of National health insurance dental scaling experience, it is necessary to increase awareness of the new dental scaling system through the promotion and oral health education about national health insurance dental scaling, and to emphasize the importance of dental Scaling by regular dental check-up.