• Title/Summary/Keyword: Scaling test

Search Result 430, Processing Time 0.04 seconds

Recognition about national health insurance of dental scaling in industry accident injury patients (스케일링 건강보험 급여화에 대한 산재환자의 인식도)

  • Lee, Hea Shoon;Lee, Kyung Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.4
    • /
    • pp.561-568
    • /
    • 2013
  • Objectives : The purpose of this study is to examine the recognition and needs on the national health insurance coverage of scaling in industry accident injury patients. National health insurance coverage of dental scaling will start in September, 2013. Methods : Subjects were 649 industrial injury patients and they completed self-reported questionnaire. Data were analysed using SPSS version 20.0 for percentage, chi-square test, t-test, ANOVA, post-hoc Scheffe test, and Pearson's correlation coefficient. Results : Recognition on national health insurance coverage of dental scaling was not fully known to industrial injury patients (24.5%). Highly educated and high income workers seemed to recognize national health insurance coverage of dental scaling (p<.001). Recognition for national health insurance coverage of dental scaling revealed a significance (r=.576, p<.001). Most of the industrial injury workers thought that 50,000 to 100,000 Korean Won of dental scaling fee is reasonable. The coverage of dental scaling should be more than twice over 20 years old. Conclusions : It is necessary to encourage the patients to take regular dental scaling checkup and make them know the health insurance coverage of scaling. The preventive oral health care may improve oral health care and quality of life.

Evaluation of Pain Reduction and Clinical Efficacy of Feedback-Controlled Ultrasonic Scaler

  • Min-ju Kim;Hee-jung Lim;Myoung-hee Kim;Young-sun Hwang;Im-hee Jung
    • Journal of dental hygiene science
    • /
    • v.23 no.2
    • /
    • pp.176-184
    • /
    • 2023
  • Background: Recently, a piezoelectric ultrasonic scaler based on a feedback control mechanism was introduced for pain relief. This study aimed to investigate the effects of a new ultrasonic scaler in reducing pain and discomfort in adults. Methods: A newly introduced ultrasonic scaler (Master 700®) was used as the test device and a conventional ultrasonic scaler device (PIEZON®) was used as the control device. Forty-one healthy adults visited the dental clinic for dental scaling but did not undergo scaling or periodontal treatment within 6 months. Intraoral examinations were performed before scaling and 3 months later; before scaling, both devices were randomly assigned on the left or right side of each dentition (split-mouth model) and scaling was performed by a registered dental hygienist. The levels of pain and discomfort during scaling were evaluated subjectively and objectively using the visual analog scale (VAS) and physiological monitoring of the heart rate (HR), respectively. Time was measured for each device. Results: All clinical indicators, except bleeding on probing, significantly improved with both devices. The treatment times were 7 minutes, 13 minutes (control) and 6 minutes, 59 minutes (test). VAS scores for pain were 4.89±2.12 (control) and 4.58±2.77 (test) points out of 10; for noise, these were 4.68±2.33 (control) and 4.55±2.55 (test), and for vibration, the values were 4.26±2.0 (control) and 4.18±2.48 (test). HR averages were 72.34±3.39 (control) and 75.97±9.78 (test) beats/min. No statistically significant differences were observed between the devices. Conclusion:The pain, discomfort levels, and scaling time of the new piezoelectric ultrasonic scaler did not differ from those of the conventional device. Further research and development are necessary for more prominent pain-relief effects of scaling devices.

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

Differences in view of dental hygienist and patient's scaling actual condition and disputes (치과위생사와 환자의 치석제거 실태와 분쟁에 대한 견해 차이)

  • Seong, Mi-Gyung;Kang, Hyun-Kyung;Kim, Yu-Rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.5
    • /
    • pp.623-633
    • /
    • 2020
  • Objectives: Since scaling has been covered by insurance, the number of patients undergoing scaling has increased. Simultaneously, legal disputes around scaling have increased. Therefore, this study was aimed at comparing the differences between the perceptions of dental hygienists and patients regarding the scaling procedure and providing dental hygienists with basic data to find ways to reduce disputes arising from these differences. Methods: A survey was conducted on 119 dental hygienists working in Busan and the South Gyeongsang Province and 110 patients who visited hospitals for scaling. Frequency analyses were performed for dental hygienists' scaling behavior and patient discomfort during scaling. The independent t-test and chi-square test were performed to compare the perceptions of dental hygienists and patients regarding the scaling procedure. Results: Polishing after scaling was performed according to 70.1% of dental hygienists but only 29.9% of patients. Oral health education was provided according to 20.4% of dental hygienists, while 79.6% of patients said that they received oral health education at the Dentiform. The scaling time was reported to be shorter by patients than by dental hygienists. Both dental hygienists and patients said that legal action was required if problems occurred during scaling, and the refund standard was that patients needed it more than dental hygienists. Conclusions: There are differences between the perceptions of dental hygienists and patients regarding scaling. Dental hygienists should identify these differences and try to prevent conflicts or disputes with patients around scaling.

Scaling Technique of Earthquake Record and its Application to Pile Load Test for Model Driven into Pressure Chamber (지진 기록의 확대(Scaling) 기법과 압력토오 말뚝모형실험에의 적용)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.19-32
    • /
    • 1996
  • Based on Trifuilac's empirical model to transform earthquake acceleration time history in the time domain into Fourier amplitude spectrum in the frequency domail an earthquake scaling technique for simulating the earthquake record of certain magnitude as the required magnitude earthquake was suggested. Also, using the earthquake record of magni dude(M) 5.8, the simulated earthquake of magnitude(M) 8.0 was established and its application to dynamic testing system was proposed. The earthquake scaling technique could be considered by several terms : earthquake magnitude(M), earthquake intensity(MMI), epicentral distance, recording site conditions, component direction and confidence level required by the analysis. Albo, it had an application to the various earthquake records. The simulated earthquake in this study was established by two orthogonal horizontal components of earthquake acceleration-time history. The simulated earthquake shaking could be applied to the dynamic pile load test for the model tension pile and the model compressive open -ended piles driven into the pressure chamber. In the static pile load test, behavior of two piles was very different and after model tension pile experienced 2 or 3 successive slips of the pile relative to the soil, it was failed completely. During the simulated earthquake shaking, dynamic behavior and pile capacity degradation of two piles were very different.

  • PDF

Design of the 1/8 Scaled HU-KINS Based on the Scaling Laws for the Experimental Investigation of Thermal-Hydraulic Effect of CANDU-6 Moderator (CANDU-6 원자로 감속재 열수력 개별영향실험을 위한 축소화 기법에 따른 1/8 축소형 HU-KINS 설계)

  • Lee, Jae-Young;Kim, Man-Woong;Kim, Nam-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.825-833
    • /
    • 2006
  • To investigate the moderator coolability for CANDU-6 reactors, a test facility (HU-KINS) has been manufactured as a 1/8 scaled-down of a calandria tank. In the design of the test facility, a scaling law was developed in such a way to consider the thermal-hydraulic characteristics of a CANDU-6 moderator. The proposed scaling law takes into consideration of the energy conservation, the dynamic similitude such as dimensionless numbers, Archimedes number (Ar) and Reynolds number (Re), and thermal-hydraulic properties similitude. Using this proposed scaling law, the thermal-hydraulic scaling analyses of similar test facilities such as the SPEL (1/10 scale) and the STERN (1/4 scale), have been identified. As a result, in the case of the SPEL, while the energy conservation is well defined, the similarities of Ar and the heat density are not well considered. As for the similarity of the STERN, while both the energy conservation and the characteristics of Ar are well defined, the heat density is not. In the meanwhile, the HU-KINS test facility with 1/8 length scaled-down is well similitude in compliance with all similarities of the energy conservation, the fluid dynamics and thermal-hydraulic properties. To verify the adequacy of the similarities in terms of thermal-hydraulics, a computational fluid dynamic (CFD) analysis has been conducted using the CFX-5 code. As the results of the CFD analyses, the predicted flow patterns and variation of axial properties inside the calandria tank are well consistant with those of previous studies performed with FLUENT and this implies that the present scaling method is acceptable.

A Study on an Analytical Approach to the Derivation of Fuzzy PI Scaling Factor (퍼지 PI scaling factor의 분석적인 유도방법에 관한 연구)

  • 전기영
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.460-463
    • /
    • 2000
  • Fuzzy logic control(FLC) has been studied extensively and has been applied in various applications. The most popular control strategy takes the Fuzzy Proportional-Integral(FPI) form while systematic methods have been developed to derive the fuzzy rules and membership functions the choice of the scaling factors remains an open problem, In this paper an analytical FPI scaling factor determining method is derived based on the functional equivalence of the PI and FPI controllers. Simulation have been carried out with a brushless DC motor drive system as test-bed the obtained results drive system as test-bed the obtained results have verified that the derived method is applicable to both the initial choice and further tuning of the FPI scaling factors.

  • PDF

Study on Component Map Scaling Technique Using a Gas Turbine Test Unit (가스터빈 시험장치를 이용한 구성품 성능선도 축척기법에 관한 연구)

  • 공창덕;고성희;기자영
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.105-109
    • /
    • 2003
  • A new scaling method for the prediction of gas turbine components characteristics using experimental data of gas turbine test unit has been proposed. In order to minimize the analyzed performance error in the this study, firstly component maps were constructed by real experimental performance data at some operating conditions and a polynomial obtained from scaling factors at given conditions, and then the simulated performance using the identified maps was compared with the performance result using the currently used traditional scaling method. In comparison, the performance analysis result by the currently used traditional scaling method was met well agreed with the real engine performance at most off-design points except for the design point. However the performance analysis result using the newly proposed scaling method had good agreement with the experimental results within maximum 5% error.

  • PDF

Study on Scaling Analysis and Design Methodology of Passive Injection Test Facility (피동 주입 시험 장치의 척도 해석 및 설계 방법론 연구)

  • Bae, Hwang;Lee, Minkyu;Ryu, Sung-Uk;Shin, Soo Jai;Kim, Young-In;Yi, Sung-Jae;Park, Hyun-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.5
    • /
    • pp.50-60
    • /
    • 2016
  • A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.