• Title/Summary/Keyword: Scale Model House

Search Result 78, Processing Time 0.021 seconds

Demand Response of Large-Scale General and Industrial Customer using In-House Pricing Model (사내요금제를 활용한 대규모 수용가 수요반응에 관한 연구)

  • Kim, Min-Jeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1128-1134
    • /
    • 2016
  • Demand response provides customer load reductions based on high market prices or system reliability conditions. One type of demand response, price-based program, induces customers to respond to changes in product rates. However, there are large-scale general and industrial customers that have difficulty changing their energy consumption patterns, even with rate changes, due to their electricity demands being commercial and industrial. This study proposes an in-house pricing model for large-scale general and industrial customers, particularly those with multiple business facilities, for self-regulating demand-side management and cost reduction. The in-house pricing model charges higher rates to customers with lower load factors by employing peak to off-peak ratios in order to reduce maximum demand at each facility. The proposed scheme has been applied to real world and its benefits are demonstrated through an example.

A Field Survey on the Structures of Small Scale Vinyl House by Growing Crops (재배작물별 비규격 소형비닐하우스의 구조실태 조사)

  • Lee, Jong-Won;Lee, Suk-Gun;Lee, Hyun-Woo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.129-132
    • /
    • 2002
  • The purpose of this study was to disclose the problems of structural safety of small scale vinyl house through investigation of actural state of plastic greenhouses by region and growing crops and the objective of a field survey is to develop safety structural model of small scale vinyl house which accounts for the most part of local horticultural facility in order to reduce damage caused by strong wind and heavy snow repeatedly every year.

  • PDF

A Study on Developing Profit Model for Remodelling of Apartment Houses (공동주택 리모델링을 위한 수익모델의 개발 연구)

  • An, Min-Jae;Pyo, Ji-Myeong;Kim, Ui-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.101-108
    • /
    • 2004
  • The physical factor having a great influence among components of making values of profit model in apartment houses is equilibrium change of house and this study suggests an alternative of remodelling. It sets profit models including model dividing household of large scale into that of small scale using value making factor of apartment house and spatial composition techniques and model integrating households of small scale and converting them into those of large scale and finds that its economy is good as over 'average', evaluative value of economy is reduced as discount rate increases and economy of remodelling is superior.

Seismic Test of a Full Scale Model of Wood House with Tiled Roof (기와집 실물크기 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.368-373
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a full scale model of wood house with tiled roof was performed. Full scale model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

An Experimental Study on the Sound Insulation Performance of Korean Traditional Windows by Using a Scale Model House (축소모형주택을 이용한 전통창호의 차음성능에 관한 실험적 연구)

  • Shin, Hoon;Jang, Gil-Soo;Song, Min-Jeong
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.47-54
    • /
    • 2006
  • This study aims to evaluate the sound insulation performance of Korean traditional paper(Hanji) windows as a material of environmental friendly building. Six types of traditional windows with 4 types of traditional window positions, were installed in l/2.5 scale model house. And then according to KS F 2235, comparative sound level differences between outdoor and indoor were measured. The main results are as follows; 1) TL(Transmission Loss) of Korean traditional paper windows, which cover one eighth of total balcony window, are ranged from 15 to 19 dB(A) in the living room and from 8 to 11 dB(A) in the balcony space. 2) TL of Korean traditional paper windows, which cover one fourth of total balcony window, are ranged from 10 to 19 dB(A) in the living room and from 8 to 10 dB(A) in the balcony space. 3) TL of Korean traditional windows with one side-one layer paper is ranged from 10 to 21 dB(A) and two side-one layer paper is 15 to 23 dB(A) and two side-two layer paper is 19 to 23 dB(A) respectively.

Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof (기와집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof (초가집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Huh, Young-Chul;Jeon, Bong-Hee
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

A Comparative Study by Age in Evaluating Web-based 3D Model House

  • Ha, Jimin;Park, Soobeen
    • Architectural research
    • /
    • v.15 no.4
    • /
    • pp.175-182
    • /
    • 2013
  • This study aims to explore age-related differences with the assessment tools in the web-based 3D virtual model house and to propose the 3D model house criteria which everyone can use easily. The participants came from three age groups, ranging from their 20s to their over 40. Presence, Usability and Space perception and cognition in the experiment for navigating and evaluating the web-based 3D model house were measured and compared through one-way ANOVA and two-way ANOVA. The results and conclusions are as follows. (1) The younger the participants were, the more positive they evaluated the experiment on Presence. However, 20s needed higher presence than other two groups. (2) 30s and over 40 groups evaluated that the 3D virtual model house was more efficient than an actual model house on Usability. When the participants were younger, the values of 'expressivity' factor were higher. (3) The younger the participants were, the more positive they perceived the virtual environment (VE) on Space perception and cognition scale. There were no significant differences in the selection of dwelling size and the floor plan type. There were no significant differences of interaction effects between age and online gaming experience on Presence and Usability. The results of the current study demonstrate that there are differences among age groups and older groups have difficulty navigating and assessing in a VE. Although older groups take longer to adapt in the VE, they regard the 3D model house as an effective tool for purchase of house.

A Study on Developing Profit Model and Analyzing Validity for Remodelling of Apartment Houses (공동주택 리모델링의 수익모델 개발과 타당성 분석 연구)

  • Kim, Eui-Sik;Pyo, Ji-Myung;An, Min-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.257-264
    • /
    • 2004
  • The physical factor having a great influence among components of making values of profit model in apartment houses is equilibrium change of house and this study suggests an alternative of remodelling. It sets profit models including model dividing household of large scale into that of small scale using value making factor of apartment house and spatial composition techniques and model integrating households of small scale and converting them into those of large scale and finds that its economy is good as over 'average', evaluative value of economy is reduced as discount rate increases and economy of remodelling is superior.

An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control (한지창호의 실내 온.습도 조절효과에 관한 실험적 연구)

  • Jang Gil-Soo;Park Sa-Keun;Song Min-Jeong;Shin Hoon
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.