• 제목/요약/키워드: Scada system

Search Result 291, Processing Time 0.369 seconds

Information security auditing Framework in Industrial control system (산업제어시스템 정보보안 감리 프레임워크 연구)

  • Lee, Chul-Soo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.1
    • /
    • pp.139-148
    • /
    • 2008
  • Information technology have led to change the automation of large industrial control system as well as business system and environments. Industrial control system(ICS) is vital components of most nation's critical infrastructures such as electricity, natural gas, water, waste treatment, transportation and communication that are based of national security, safety of citizen and development of national economy According to the change of business environment, organizational management pushed integration all of the system include MIS and ICS. This situation led to use standard information technologies for ICS, this transition has been to expose ICS to the same vulnerabilities and threats that plague business system. Recently government obliged owners of the public information system to audit for safety, efficiency and effectiveness, and also obliged the owners of national infrastructure to improve their system security as a result of vulnerability analysis. But there doesn't prepare a security architecture and information security auditing framework of ICS fur auditing. In this paper, I suggested the security architecture and information security auditing framework for ICS in order to prepare the base of industrial system security auditing.

A Proposal of Risk Management Framework for Design as a Secure Power Control System (안전한 전력 제어시스템 설계를 위한 위험관리 프레임워크 제안)

  • Park, Jun Yong;Shin, Sumin;Song, Kyoung-Young
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.425-433
    • /
    • 2016
  • In smart grid, enhancement of efficiency and interoperability of electric power system is achieved through the connection with outer network, and this induces that power grid system is threatened increasingly, becomes the main target of cyber terrorism, and is sincerely required to design the secure power system. Although SSDLC(Secure System Development Life Cycle) is used for risk management from the design phase, traditional development life cycle is somewhat limited for satisfaction of information security indicator of power control system. Despite that power control system should reflect control entities of information security considering its own characteristics, validation elements are insufficient to apply into real tasks based on existing compliance. To make design of diagnostic model and assessment process for power control system possible and to give a direction for information security and present related indicator, we propose the new risk management framework of power control system which is applied operational security controls and standard architecture presented by IEC 62351 TC 57 with enterprise risk management framework.

A Study on Power Control using PMS (PMS 시스템을 활용한 전력제어에 관한 연구)

  • Kim, Sung-Cheol;Kim, Kyoung-Wook;Woo, Chun-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.194-198
    • /
    • 2016
  • The electric power industry have recently been building out Smart Grids, a two-way electricity grid that connects power consumers and producers to a network that enables one to respond quickly to any eventuality. The construction of a two-way electricity grid means that the power control process becomes unified, from what used to be separate processes that originate individually from the consumption phase and the production and supply phases. The role of power control that takes place within each section of the power system may be independent. However, this does not mean the independent control sections are operated individually, but are configured to meet a single target and purpose. Each control section possesses enough degree of independency to respond to eventualities that may occur within different stages of the power system, but at the same time, possesses unified system elements for the stability of the entire power system. From this perspective, Smart Grids are widely regarded as the most rational power industry operation plan. A variety of different control and communication systems can be applied for an effective deployment of Smart Grids. Recently, we have seen systems such as PMS(Power Management System) and PAS(Process Automation System) applied in the deployment of Smart Grids, which are developed from the techniques utilized in the industry. The PMS is attracting particular attention for its power operations management ability. In this study, we propose plans for improvement in the rational development of power system controls through case studies of live PMS operations.

A Study on integrated water management system based on Web maps

  • Choi, Ho Sung;Jung, Jin Young;Park, Koo Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.8
    • /
    • pp.57-64
    • /
    • 2016
  • Initial prevention activities and rapid propagation conditions is the most important to prevent diffusion of water pollution. If water pollutants flow into streams river or main stresm located in environmental conservation area or water intake facilities, we must predict immediately arrival time and the diffusion concentration to the proactive. National Institute of Environmental Research developed water pollution incident response prediction system linking dam and movable weir. the system is mathematical model which is updated daily. Therefore it can quickly predict the arrival time and the diffusion concentration when there are accident of oil spills and hazardous chemicals. Also we equipped with mathematical model and toxicity model of EFDC(Environmental Fluid Dynamics Code) to calculate the arrival time and the diffusion concentration. However these systems offer the services of an offline manner than real-time control services. we have ensured the reliability of data collection and have developed a real-time water quality measurement data transmission device by using the data linkage utilizing a mode bus communication and a commercial SCADA system, in particular, we implemented to be able to do real-time water quality prediction through information infrastructure of the water quality integrated management business created by utilizing the construction of the real-time prediction system that utilizes the data collected, the Open map, the visual representation using charts API and development of integrated management system development based on web maps.

A Study on Control System Cyber Security Education & Training Method (제어시스템 사이버 보안 교육훈련 방안 연구)

  • Kim, Kyeong-Ho;Maeng, YounJae;Jang, MoonSu;Ryou, Jae-Cheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.3
    • /
    • pp.645-656
    • /
    • 2019
  • As the number of cyber threats to control systems increases, the need for control system cyber security is also increasing. Currently, various cyber security related education and control system education are being conducted. However, it does not fully reflect the characteristics of the control system and the characteristics of the participants. In this paper, we propose a training system and technique to enhance the control system cyber security capability. To this end, we analyze the limitations of existing security education. Based on the results, we develop a control system training environment model based on the IEC62443 Standard and develop an ARCH based training method.

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

Design and Implementation of A Operation and Management Supporting System for Power Telecommunication Network Using Knowledge Database (지식 데이터베이스를 이용한 전력통신망 운용 관리 지원시스템 설계 및 구현)

  • Oh, Do-Eun;Park, Myoung-Hye;Sung, Gi-Hyeok;Lee, Jin-Kee;Cho, Sun-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2794-2796
    • /
    • 2002
  • 기업 네트워크에서 안전하고 효과적이며 안정된 망 운영관리 환경 제공은 당면한 중요과제이며 기업 경쟁력의 핵심인 정보기술을 통한 생산성과도 연계성을 갖고 있다. 특히 전력통신망의 경우 전자메일, 회계관리, 전자결재, 도면자료관리 등의 데이터 통신망에서부터 IBM 온라인, 사내 방송망, 전력계통설비 원방 제어용 시스템들 간을 연결하는 EMS, SCADA 등 전력 수급용 전용 통신망에 이르기까지 다양한 종류의 통신망이 구축 운용되고 있다. 이러한 기업환경에 따라 네트워크를 효율적으로 관리하기 위한 네트워크 관리 시스템에 대한 관심이 증대되고 있으며 많은 네트워크 관리 시스템들이 도입되어 운영되었으나 이들 관리 시스템들은 모니터링에 의한 통계값 제공과 같은 단순 평면적인 관리 기능만을 제공한 뿐 네트워크의 특성과 환경에 따른 분석, 진단 기능은 제공하지 못하고 있다. 이와 더불어 네트워크 관리자는 보다 손쉬운 방법으로 네트워크를 관리하고자 하며, 보다 지능적이고 효율적으로 관리하고자 한다. 하지만 관리 시스템이 모든 네트워크에 대해 효율적이고 지능적인 관리 기능을 제공하기는 매우 어려우며 이는 장기간의 관리 네트워크의 특성과 트래픽 형태를 파악한 후에나 가능하다. 결국 지능적이고 효율적인 네트워크 관리는 네트워크의 특성과 함께 이전에 관리자에 의해서 내려졌던 관리 행위 및 의견 그리고 조치에 대한 이력정보를 학습하고 있을 때만 가능하다. 본 논문은 전력통신망을 대상으로 전력통신망이 지닌 네트워크 특성을 반영하며 네트워크 운영 과정에서 축적된 관리자의 의견과 이에 대한 조치를 지식 데이터베이스화하여 지능적인 관리 시스템을 제공하기 위한 기반 시스템으로써 전력통신망 운용 관리 지원시스템을 설계 및 구현하였다. 본 시스템은 향후 지식 정보를 학습하고 이를 바탕으로 논리적인 추론을 통해 관리 네트워크를 지능적이고 자동적으로 관리할 수 있는 시스템으로 확대 개발될 것이다.

  • PDF

Design and Implementation of Gateway System for Digital Substation based on IEC61850 (IEC61850 기반 디지털변전소 게이트웨이 시스템의 설계 및 구현)

  • Hyu, Mu-Yong;Lee, Jung-Hyun;Choi, Jon-Phil;Song, Wan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.233_234
    • /
    • 2009
  • 2005년 유틸리티 산업분야 국제표준 규약으로서 IEC61850이 발표된 이후, 변전소 자동화 시스템 설계 및 구현을 위한 새로운 패러다임으로 인식되고 있다. 현재, 유럽시장을 중심으로 IEC61850 규약과 호환되는 많은 제품들이 출시되고 있고 다양한 구현사례를 통해 그 적용가능성 및 타당성이 검증되고 있다. 그러나, 변전소 자동화의 기본 통신규약으로서 IEC61850이 도입될 경우, 이미 기존에 설치되어 운용중인 수많은 전력설비 감시/제어 시스템 및 상위 제어센터와의 통신 호환성 문제가 발생되며, 향후, IEC61850 기반의 디지털변전소 확대 적용에 장애 요인으로 대두되고 있다. 본 논문에서는 이러한 문제점을 해결하기 위해 IEC61850 기반의 변전소자동화 용 게이트웨이 시스템을 설계하고 구현하였다. 제안된 시스템은 기존에 운용되고 있는 전력설비 감시/제어 시스템과의 호환성 제공은 물론, 변전소 내의 IEC61850 IED들과 상위제어센터 내의 송변전 SCADA 시스템간 통신 및 상호운영성을 제공한다. 또한, 시스템의 가용성 및 신뢰성을 보장하기 위한 이중화 메커니즘을 지원한다.

  • PDF

Monitoring system design&Implementation using wireless solution (무선 통신을 사용한 모니터링 시스템의 설계 및 구현)

  • Jeon Yoon-Ho;Woo Jong-Hyun;Kim Young-Ryun;Kim Hee-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.39-42
    • /
    • 2002
  • RS-232C는 정보기기들을 연결하는 직렬통신 표준으로, 간단한 구조로 인해, 복잡한 요구 조건이 없는 상용 기기들의 제어 및 감시용으로 사용되고 있다. 최근 무선동신기술이 발전함에 따라, 저가격의 무선통신 기술을 활용하여 무선 RS-232C에 대한 요구가 늘어나고 있다. 무선 RS-232C로 기존 유선의 RS-232C를 대체함으로서, 기존 시스템의 변경없이 편리한 접속기능을 대체한 수 있을 것이다. 본 논문에서는 유선 RS-232C를 대체하는 무선 RS-232C 모듈을 채용하여, 전력제어에 사용하는 배전자동화 장치의 관리를 간편하게 하는 시스템의 구현에 대해서 다루고 있다. 배전 자동화시스템은 일종의 SCADA시스템의 일부로서, 통신 프로토콜로서 산업용 DNP3.0을 사용하고 있다. 무선 RS-232C 링크의 신뢰성을 확보하기 위하여, 무선 구간에 DNP3.0을 채택하였으며, 무선 통신방식으로는 무선 RF, 블루투스(Bluetooth), 무선랜(wireless LAN)등 3가지 방식을 채용하여, 설계, 구현내용을 기술하였다.

  • PDF

Distributed State Estimation Algorithm for Power Distribution System (배전계통을 위한 분산형 상태추정 알고리즘)

  • Lee, S.S.;Park, J.K.;Moon, S.I.;Yoon, Y.T.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.274-276
    • /
    • 2005
  • 배전계통 상태추정이란 배전계통을 운영하고 제어하기 위하여 모선전압, 선로조류, 모선부하와 같은 상태변수들의 측정된 값을 이용하여 여러가지 운영에 필요한 정보를 활용하고 배전계통으로부터 측정치에 기초하여 미지의 상태변수들을 추정하는 것이다. 변전소 제어센터에 있는 SCADA 시스템은 실시간으로 배전계통을 모니터링하고 제어하기 위하여 전력계통을 주기적으로 스캔하고 엄청난 양의 데이터를 획득하여 처리한다. 이들 측정값들은 유효전력, 무효전력, 전압, 전류, 스위치나 차단기의 상태들이다. 이들 데이터들은 중앙전력계통 제어센터나 지역제어센터로부터 산발되어 있는 정보를 대부분 RTU를 통하여 획득하게 된다. 이러한 이유로 배전계통의 상태추정은 송전계통과는 달리 배전계통 자체가 토폴로지상으로 산발되어 있을 뿐만 아니라 대규모이기 때문에 분산형으로 구성하여 처리하는 알고리즘을 필요로 한다. 본 논문에서는 배전계통에 대한 분산형 상태추정기의 알고리즘을 제안하고자 한다.

  • PDF