The effect of gain recovery at the optical fiber amplifier by the input pulse train (광섬유 증폭기에서의 입력 펄스 열에 의한 Cain Recovery 특성)

  • 이재명;이영우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.459-463
    • /
    • 2002
  • We studied the effect of gain recovery at the optical fiber amplifier by the input pulse trains We also theoretically analyzed the limitation of the saturation and recovery time for the PDFA(Praseodymium-Doped Fiber Amplifier) which has the spectral gain at 1.3${\mu}{\textrm}{m}$ band. We can predict the interval between the pulse train, pump power, and the effect of the saturation and recovery time which is affected to the amplification of the optical pulse.

The effect of gain recovery at the optical fiber amplifier by the input pulse train (광섬유 증폭기에서의 입력 펄스 열에 의한 Cain Recovery 특성)

  • 이재명;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.505-508
    • /
    • 2002
  • We studied the effect of gain recovery at the optical fiber amplifier by the input pulse trains. We also theoretically analyzed the limitation of the saturation and recovery time for the PDFA(Praseodymium-Doped Fiber Amplifier) which has the spectral gain at 1.3${\mu}{\textrm}{m}$ band. We can predict the interval between the pulse train, pump power, and the effect of the saturation and recovery time which is affected to the amplification of the optical pulse.

  • PDF

Effects of Abdominal Breathing Practice on Oxygen Saturation and Pulserate for Insomnia in Middle-aged Women (복식호흡 수련이 중년여성의 불면증 산소포화도와 맥박에 미치는 영향)

  • Jeon, Gesam;Kim, Yeon Woo;Lee, Ji Kwan
    • Journal of Naturopathy
    • /
    • v.11 no.2
    • /
    • pp.116-122
    • /
    • 2022
  • Background: Studies on the effect of abdominal or thoracic breathing therapy on sleep or blood oxygen concentration are still scarce. Purpose: This study was to examine the effect on blood oxygen saturation and pulse variability, changes in the severity of insomnia, changes in wakefulness before sleep, and dysfunctional beliefs and attitudes toward the Korean version of sleep in women in their 50s after healing with abdominal breathing and thoracic breathing. We investigated the effect. Methods: Subjects were investigated before and after the change of breathing (breathing) therapy for 12 weeks, 3 times a week, and 36 breaths perweek. Results: It wa evaluated respiratory healing as having no significance in the pulse rate change. However, oxygen saturation was significant in the experimental group, increasing to 93.60 SpO2% before the respiratory rally and 96.5 SpO2% after respiratory recovery (p < .002). In addition, the insomnia severity scale and dysfunctional beliefs about sleep significantly decreased after respiratory rally than before (p < .000). Conclusions: It evaluated that respiratory therapy for the subjects is beneficial to health as it is effective for insomnia, pulse, and oxygen saturation.

SpO2 Measurement Algorithm for PPG Signal with Motion Artifacts (동잡음을 가진 PPG 센서에서의 산소포화도 측정 알고리즘)

  • Jang, Seong-Jin;Choi, Kue-Lak;Park, Keun-Hae;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.192-198
    • /
    • 2018
  • Pulse oximetry is a non-invasive method for monitoring how much oxygenated hemoglobin is present in the blood. The principle of pulse oximetry is based on the red infrared light adsorption characteristics of oxygenated and deoxygenated hemoglobin. Even through the convenience of a pulse oximeter, its weak signal-to-noise ratio against motion artifacts and low perfusion makes it difficult to be accepted by execs devices. Several researchers have suggested the use of an adaptive noise cancellation (ANC) algorithm. They have demonstrated that ANC is feasible for reducing the effects of motion artifacts. Masimo Corporation developed a discrete saturation transformation (DST) algorithm that uses a reference signal and ANC. In commercial devices, it is very hard to escape it because Masimo's patents are very powerful and a better method is yet to be developed. This study proposes a new method that can measure noise saturation as well as accurate oxygen saturation from signals with high motion artifacts without using ANC and DST. The proposed algorithm can extract a normal signal without noise from a signal with motion artifacts. The reference signal from a pulse oximeter simulator was used for the evaluation of our proposed algorithm and achieved good results.

Saturation impulses for dynamically loaded structures with finite-deflections

  • Zhao, Ya-Pu;Yu, T.X.;Fang, J.
    • Structural Engineering and Mechanics
    • /
    • v.3 no.6
    • /
    • pp.583-592
    • /
    • 1995
  • The concept of "Saturation Impulse" for rigid, perfectly plastic structures with finite-deflections subjected to dynamic loading was put forward by Zhao, Yu and Fang (1994a). This paper extends the concept of Saturation Impulse to the analysis of structures such as simply supported circular plates, simply supported and fully clamped square plates, and cylindrical shells subjected to rectangular pressure pulses in the medium load range. Both upper and lower bounds of nondimensional saturation impulses are presented.

A Study of the Gain Recovery Properties at the Thulium-doped fiber Amplifier ($Tm^{3+}$가 첨가된 광섬유 증폭기의 이득회복 특성)

  • 이재명;황대석;김규식;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.533-534
    • /
    • 2002
  • In this paper, we studied the transient gain response in TDFA(Thulium-Doped Fiber Amplifier) theoretically. We also investigated the limitation of the gain saturation and recovery time when the short pulse trains are incident into the TDFA with the spectral gain band in 1.47${\mu}{\textrm}{m}$ for using at WDM. We can predict the interval between the pulse train, pump power and the effect of the saturation and recovery time which is affected to the amplification of the optical pulse.

  • PDF

The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

  • Prasetyono, Theddeus O.H.;Adianto, Senja
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.505-509
    • /
    • 2013
  • Background The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. Methods An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. Results The mean times from the vessel clamping until the saturation became undetectable were $20.19{\pm}2.13$ seconds and $74.91{\pm}10.57$ seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was $34.5{\pm}11.72$ minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. Conclusions The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography (광전용적맥파를 이용한 요골동맥 산소포화도 측정 시스템의 연구)

  • Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.11-18
    • /
    • 2010
  • In this study, the pulse of radial artery and oxygen saturation are detected using photoelectric plethysmograph method. Using our device designed reflection type, we can detect the reflected light by radial artery and by switching circuit, we can also separate to 625nm band signal and 940nm band signals. The separated signals are converted as a pulse data by the pulse signal processing circuit. In this study, the reflection type of oxygen saturation calculation method is applied instead of the transmission type because of the reflection type sensor is used to measure the radial artery. As a result, we can detect about 97% accuracy of the oxygen saturation compare with the conventional method. For the accurate signals, the wrist band with sensor was designed and fixed on the radial artery. As a result, this wrist band type sensor was applicable to prevent position errors from motion artifact and could increase the accuracy during the measuring.

A STUDY ON SOLUTION AGAINST CORE SATURATION INSTABILITY AT AN HVDC CONVERTER

  • Yang Byeong-Mo;Kim Chan-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.591-599
    • /
    • 2001
  • The paper identifies a severe form of core saturation instability in an DC/AC interaction system. It then seeks solutions to the problem by HVDC control means. This is achieved by a proper design of the Voltage Dependent Current Order Limiter (VDCOL), the Current Regulator and Timing Pulse generator. Supplementary control loops have also been introduced to result in a satisfactory performance as compared to that obtained one with the use of uncharacteristic harmonic filter on the AC side. Robustness of all the options has been demonstrated through recovery performance of the DC link in response to both I-phase and 3-phase 5 cycle faults on both rectifier and inverter commutating buses.

  • PDF

A Study on Solution against Core Saturation Instability at HVDC Converter

  • Yang, Byeong-Mo;Kim, Chan-Ki;Koh, Bong-Eun;Moon, Young-Hyun
    • Journal of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.297-304
    • /
    • 2002
  • The paper identifies a severe form of core saturation instability in a DC/AC interaction system. It then seeks solutions to the problem by HVDC control means. This is achieved by a proper design of the Voltage Dependent Current Order Limiter (VDCOL), the Current Regulate. and Timing Pulse generator. Supplementary control loops have also been introduced to result in a satisfactory performance as compared to that obtained one with the use of uncharacteristic harmonic filter on the AC side. All the options have been demonstrated through recovery performance of the DC link in response to both 1-phase and 3-phase 5 cycle faults on both rectifier and inverter commutating buses.