• Title/Summary/Keyword: Saturation pulse

Search Result 192, Processing Time 0.025 seconds

Long-term Oxygen Therapy for Chronic Respiratory Insufficiency: the Situation in Korea after the Health Insurance Coverage: a Multi-center Korean Survey -Study for the Development and Dissemination of the COPD Guidelines, Clinical Research Center for Chronic Obstructive Airway Disease- (가정산소치료의 보험급여 실시 이후 처방 실태: 다기관 조사 -만성기도폐쇄성질환 임상연구센터 제3세부과제 만성기도폐쇄성질환 진료지침 개발/보급 연구-)

  • Park, Myung Jae;Yoo, Jee-Hong;Choi, Cheon Woong;Kim, Young Kyoon;Yoon, Hyoung-Kyu;Kang, Kyung Ho;Lee, Sung Yong;Choi, Hye Sook;Lee, Kwan Ho;Lee, Jin Hwa;Lim, Sung-Chul;Kim, Yu-Il;Shin, Dong Ho;Kim, Tae Hyun;Jung, Ki-Suck;Park, Yong Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.2
    • /
    • pp.88-94
    • /
    • 2009
  • Background: From November 2006, The national health insurance system in the Republic of Korea began to cover prescribed long-term oxygen therapy (LTOT) in patients with chronic respiratory insufficiency. This study examined the current status of LTOT after national health insurance coverage. Methods: Between November 1, 2006 and June 30, 2008, the medical records of patients who were prescribed LTOT by chest physicians were reviewed. The data was collected from 13 university hospitals. Results: 197 patients (131 male and 66 female) were prescribed LTOT. The mean age was 64.3${\pm}$13.0 years. The most common underlying disease was chronic obstructive pulmonary disease (n=103, 52.3%). Chest physicians prescribed LTOT using arterial blood gas analysis or a pulse oxymeter (74.6%), symptoms (14%), or a pulmonary function test (11.2%). The mean oxygen flow rate was 1.56${\pm}$0.68 L/min at rest, 2.08${\pm}$0.91 L/min during exercise or 1.51${\pm}$0.75 L/min during sleep. Most patients (98.3%) used oxygen concentrators. Only 19% of patients used ambulatory oxygen supplies. The oxygen saturation before and after LTOT was 83.18${\pm}$10.48% and 91.64${\pm}$7.1%, respectively. After LTOT, dyspnea improved in 81.2% of patients. The mean duration of LTOT was 16.85${\pm}$6.71 hours/day. The rental cost for the oxygen concentrator and related electricity charges were 48,414${\pm}$15,618 won/month and 40,352${\pm}$36,815 won/month, respectively. Approximately 75% of patients had a regular visit by the company. 5.8% of patients had personal pulse oxymetry. 54.9% of patients had their oxygen saturation checked on each visit hospital. 8% of patients were current smokers. The most common complaint with LTOT was the limitation of daily activity (53%). The most common complaint with oxygen concentrators was noise (41%). Conclusion: The patients showed good compliance with LTOT. However, only a few patients used an ambulatory oxygen device or had their oxygen saturation measured.

Chemical Saturation Breath-hold Fast MR Imaging for characterization of Regional Fatty Changes in Liver (화학적 포화 호흡정지 급속 자기공명영상에서 국소적 간지방병변의 특성화)

  • 김동국;유정식;김태훈;오세정;김지형
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.135-141
    • /
    • 1997
  • Purpose: To assess the usefulness of breath-hold fast MR imaging of liver with fat suppression (FS) by application of chemical saturation technique in the diagnosis of regional fatty changes suspected in sonography. Materials and Methods: Thirteen patients who had focal lesions with diffuse, homogeneous signal changes after FS through chemical saturation technique without additional changes of imaging parameter during MR imaging of liver were selected. T1-weighted fast low-angle shot and T2-weighted turbo spin-echo sequences were obtained with or without FS during each single breath-holding session. Subjective changes of signal intensity between the pre-FS and the FS images were compared with the sonographic findings in each lesion. Results: Seven lesions of decreased signal intensity after FS on T1 or T2-weighted images, including three lesions only at FS T1 images, were regarded as focal fat infiltration. All seven lesions had compatible sonographic findings as homogenously echogenic areas. Another six lesions of subjectively increased signal intensity including two lesions only at FS T2 images were regarded as focal fat sparing. All six lesions had sonographic findings as homogenous echo poor areas suggesting focal fat sparing. In cases regarded as fat infiltration, score changes were more prominent at FS T1 images than FS T2 images(p=0.0002). In cases regarded as fat sparing, score changes were more prominent at FS T2 images than FS T1 images(p=0.042). Conclusion: Breath-hold fast T1 and T2-weighted MR imaging with and without chemical saturation pre-pulse may be sufficient for characterization of regional fatty changes in the differential diagnosis of focal hepatic lesion found at sonography.

  • PDF

Selective Adsorption of Sulfur Compounds from Natural Gas Fuel Using Nanoporous Molecular Sieves (나노세공 분자체를 이용한 천연가스 연료로부터 황 화합물의 선택적 흡착)

  • Kim, Hoon-Sung;Chung, Jong-Kook;Lee, Seok-Hee;Cheon, Jae-Kee;Moon, Myung-Joon;Woo, Hee-Chul
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.64-71
    • /
    • 2007
  • The selection of a suitable adsorbent for removing organic sulfur compounds tetrahydrothiophene (THT) and t-butylmercaptan (TBM) from natural gas has been carried out. The saturation adsorption capacity for the sulfur compounds were determined by pulse adsorption method for a group of nanoporous materials, including Na-Y, Na-ZSM-5, Na,K-ET(A)S-10, Na-Mordenite, Na,K-Clinoptitolite, Ti/MCM-41, Ti/SBA-15 and amorphous titanosilicates. Among the materials tested, Na-Y and Na,K-ET(A)S-10 zeolites showed high adsorptive capacities for THT and TBM. The saturation capacity for THT on Na,K-ETS-10 was comparable with that on Na-Y zeolite, which is well known as an effective adsorbent. The capacity and adsorptivity for THT and TBM on Na,K-ETAS-10 were improved by an increase in crystallinity of Na,K-ETAS-10. An investigation of the competitive adsorption between THT and TBM from the breakthrough test using a simulated natural gas indicates that Na,K-ETS-10 selectively adsorbs THT. The breakthrough capacity for THT on Na,K-ETS-10 was 1.19 mmol/g. The results show that the high adsorption performance of Na.K-ETS-10 and Na,K-ETAS-10 is due to the highly exchanged cations in the zeolitic structure which exhibit the strong electrostatic interactions with organic sulfur compounds and their wide pore nature.

  • PDF

A Study on the Effect which the Method of Deep Breathing with the Use of Incentive Spirometer has on the function of pulmonary Ventilation - In Upper Abdominal Operation Patients - (Incentive Spirometer를 사용한 심호흡 방법이 폐환기 기능에 미치는 효과에 관한 연구 -상복부 수술 환자를 대상으로-)

  • 김종혜;변영순
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.268-280
    • /
    • 1991
  • The nursing intervention for the prevention of the pulmonary complication and of the function lowering of pulmonary ventilation which emerge with high generation frequency during the nursing of operation patient is necessary for performing the qualitative nursing for operation patient. So, this researcher tried this study so as to obtain the data which can be utilized for the trial of nursing intervention, by grasping the effect that the deep breathing with Incentive Spirometer has on the function of pulmonary ventilation, analysing the factor to have influence on the function of pulmonary ventilation, and applying the effective method of deep breathing to the clinic. By making 42 patients who underwent the operation of upper abdomen after admitting G Hospital in Seoul from Mar. 7, 1991 to Apr.30, 1991 as the object, they were classified into the experiment group that the deep breathing was made with the use of Incentive Spiromenter and the comparison group that the deep breathing exercise was made without the use of Incentive Spirometer. And then, by measuring Tidal Volume and Forced Vital Capacity with Respirometer and $O_2$ Saturation with Pulse Oximeter at preoperation postoperation 24 hours, 72 hours, and 120 hours data were collected. The collected data were analyzed with of, average, standard deviation, x$^2$-test, t-test and ANOVA by SPSS. The result of this study is as follows : 1. As for the hypothesis that the function of pulmonary ventilation at postoperation 24 hours, 72 hours and 120 hours will be better in the experiment group that the deep breathing was made with the use of Incentive Spirometer, in comparison with the comparison group that deep breathing was made without the use of Incentive Spirometer, experiment group and comparison group didn't show the significant difference in Tidal Volume, Foreced Vital Capacity and $O_2$ Saturation at postoperation 24 hours and 72 hours. But experiment group and comparison group showed the significant difference in Tidal Volume at postoperation 120 hours (p<0.01). So, this hypothesis was supported partially. 2. The variables that there were the significant differences about the function of pulmonary ventilation in experiment group at postoperation 24 hours stastically were smoking existence (p<0.05), and the variables that there were not significant differences about the function of pulmonary ventilation were distinction of sex, age, anesthetic duration, smoking extent, body weight, surface area of body, existence of narcotic use, regular exercise existence, and past experience existence of respiratory disease. As above result, it appeared that the method of deep breathing with the use of the Incentive Spirometer is more effective for the function recovery of pulmonary ventilation, in comparison with the deep breathing without use of Incentive Spirometer and that smoking existence was the factor to have influence on the function of pulmonary ventilation. In the aspect of clinic, the trial of nursing intervention of deep breathing with use of Incentive Spirometer is expected. And, in the aspect of study, the study through various operative site patients about the effect of Incentive Spirometer use at the clinic will have to be confirmed.

  • PDF

The Effect of Acupuncture Treated by Tonification and Sedation Manipulation at LI4 and KI7 on Lacking of Sweating in Cold Environment(II) (합곡(合谷) 복류(復溜) 보사(補瀉) 시술(施術)이 소한(少汗)에 미치는 영향(影響)(II))

  • Na, Chang-Su;Choi, Chan-Hun;Kim, Young-Sun;Kim, Wang-In;Youn, Dae-Hwan
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.203-216
    • /
    • 2010
  • Objectives : The purpose of this study is to identify the effect of tonifying or sedative manipulation on LI4 and KI7 for sweet deficiency under cold environment. Methods : The participants were divided into 4 groups; intact group without acupuncture(Intact), acupuncture group inserting straightly with LI4 & KI7 method((LI4-straight KI7-straight), acupuncture group inserting twisting with LI4 tonificaton & KI7 tonificaton method(LI4-tonify KI7-tonify) and acupuncture group inserting twisting with LI4 sedation & KI7 sedation method(LI4-purge KI7-purge). We obtained the baseline data under cold condition with the temperature $14{\pm}1^{\circ}C$. After making the participant staying under cold condition for 10 minute, we measured sweating rate on skin surface and biological responses such as body temperature, oxygen saturation, pulse rate, systolic blood pressure, diastolic blood pressure, deoxy-Hb and oxy-Hb in subcutaneous. Results : The sweating rate on skin surface was not different in all treatment groups compared to the intact group. The body temperature was significantly increased in LI4-straight KI7-straight group compared to the intact group. The oxygen saturation significantly increased in LI4-purge KI7-purge group compared to the intact group. The systolic blood pressure was significantly increased in LI4-purge KI7-purge group compared to the intact group. The deoxy-Hb was significantly decreased in LI4-purge KI7-purge group compared to the intact group. Conclusions : The above results, the effect of LI4, KI7 acupuncture due to the tonifying or sedative manipulation on sweating control could be observed. However, other biological responses with the acupuncture of tonifying or sedative manipulation were giving different expressions. We suggest that continued research of tonifying or sedative manipulation is of importance order to find these expressions.

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF

The changes of symptom, EKG and hemodynamic in healty firefighters after delivering multiple cycles of cardiopulmonary resuscitation (반복적인 심폐소생술 시행 후 건강한 소방대원에서 나타나는 증상, 심전도 및 혈역학적 변화)

  • Lee, Hyo-Ju;Kim, Ho-Jung;Jung, Eun-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.381-388
    • /
    • 2017
  • The CPR guidelines emphasize the delivery of effective chest compressions but do not address the effects of chest compressions on CPR providers. This study determined the effects of chest compressions on healthy adult firefighters' symptoms, hemodynamics, and electrocardiography after performing multiple cycles of CPR. Healthy adult firefighters were trained in CPR and performed CPR on mannequins. The provider vital signs, electrocardiography, and fatigue scores were determined immediately before CPR, after 5cycles of CPR, and after 10 cycles of CPR. In addition, the presence of clinical symptoms among the providers was determined after CPR; 39 firefighters participated in the study. Their mean age was $35.54{\pm}10.26years$. Many providers developed fatigue, shortness of breath, and dizziness. Significant changes in heart rate (p=0.000), respiratory rate (p=0.010), end-tidal CO2(p=0.000), O2 saturation(p=0.000), and pulse pressure (p=0.000) were observed after both 5 and 10 cycles of CPR. One participant developed sinus dysrhythmia and premature ventricular contractions after 10 cycles of CPR. The delivery of chest compression results in fatigue and hemodynamic alterations in many young healthy adults after performing 5 or 10 cycles of CPR. The CPR guidelines and education should take into consideration the effects of chest compressions on CPR providers.

Analysis of Change Rate of SBP and DBP Estimation Fusion Algorithm According to PTT Measurement change PPG Pulse Wave Analysis (PPG 맥파 분석의 PTT 측정변화에 따른 SBP, DBP 추정 융합 알고리즘 변화율 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.35-40
    • /
    • 2020
  • Recently, devices such as smart watches capable of measuring small biosignals have been released. Body composition, blood pressure, heart rate, and oxygen saturation can be easily obtained. However, the part that is not trusted by the user is accuracy. These biosignals are sensitive to the external environment and have large fluctuations depending on the conditions inside the subject's body. Blood pressure measurements, in particular, still give different results, depending on how the conditions in the body are handled. Therefore, in this study, PPG was analyzed to measure PTT at two points of 80% and 100%, the highest in PTT measurement. The effect of the measured value on SBP and DBP was analyzed and a method was proposed to increase the accuracy. As a result of the study, the measured value of PTT at 80% of the peak PPG is more effective in estimating blood pressure of SBP and DBP than the value measured at 100%. In the regression analysis of the rate of change blood pressure estimation, the coefficient of determination of SBP (80%) was 0.6946, and DBP (100%) was 0.547.

Safety and Efficacy of Submucosal Midazolam When Combined with Oral Chloral Hydrate, Hydroxyzine and Nitrous Oxide Sedation by using Houpt's Scale (Midazolam을 구강 점막 하로 병용 투여한 진정법의 안정성과 Houpt Scale을 이용한 진정효과에 대한 연구)

  • Park, Mi-Koung;Kim, Yun-Hee;Jung, Sang-Hyuk;Beak, Kwang-Woo
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.6 no.2 s.11
    • /
    • pp.103-112
    • /
    • 2006
  • Background: The purpose of this study was to compare the clinical safety and effect with and without additional submucosal midazolam to oral chloral hydrate and hydroxyzine when used for pediatric conscious sedation in a clinical dental environment. Methods: Thirty one cases of pediatric conscious sedations were performed in this study. Selection criteria included good health (ASA I), under 6 years old, 20 kg of body weight, uncooperative behavior and the need for sedation to receive dental treatment including anesthesia and restorative or surgical procedure for at least two teeth. In each visit, patients were randomly assigned into one of two groups; CH group: chloral hydrate (60 mg/kg), hydroxyzine (1 mg/kg), CH-M group: chloral hydrate (60 mg/kg). hydroxyzine (1 mg/kg) and submucoal midazolam (0.1 mg/kg). 50% nitrous oxide-oxygen was maintained during the sedation period Sedations were monitored using a pulse oximeter for estimating pulse rate (PR) and percutaneous oxygen saturation ($SpO_2$). Behavior response rated using Houpt's scale and need of restraint was assessed every 2 minutes through 30 minutes of operative procedure reviewing the videotape recording. Evaluation of overall behavior success was performed using modified overall behavior rate of Houpt's scale. Data was analyzed using t-test. Results: PR and $SpO_2$ for both groups remained within the normal values. The mean scores for sleep and movement of CH-M group were higher than those of CH group (P < 0.05). There were no significant difference in mean score for crying between two groups. The mean scores of overall behavior of CH-M group was higher than those of CH group (P < 0.01). Reinstraint of CH-M group was less required than that of CH group (P < 0.05). Conclusions: Oral chloral hydrate (60 mg/kg) and hydroxyzine (1 mg/kg) combined with submucosal injection of midazolam was safer and showed more improved sedation effect than oral chloral hydrate (60 mg/kg) and hydroxyzine (1 mg/kg) without midazolam for sedation of pediatric dental patients.

  • PDF

The Effects of Leg Elevation and Stretching Exercise on Monitored Anesthesia Care (MAC) with Dexmedetomidine (Dexmedetomidine 감시마취관리 환자의 회복 시 적용한 하지거상 및 말초운동의 효과)

  • Lee, Hee Jin;Lee, In Suk;Jung, Yeo Jin;Lee, Eun Jin;Park, Jeong On
    • Journal of Korean Clinical Nursing Research
    • /
    • v.22 no.3
    • /
    • pp.249-256
    • /
    • 2016
  • Purpose: The purpose of this study was to examine the effect of leg raising and peripheral excercise on recovery of the patients who were applied with dexmedetomidine for their dental surgery. Methods: There were two groups, the experimental group (n=35) and control group (n=35), in this study. We checked blood pressure, pulse rate, oxygen saturation, sedation level and symptoms such as dizziness and somnolence every 30 minutes. These parameters were assessed throughout the participants' recovery room stay. Leg raising and peripheral excercise were conducted in the experimental group in the recovery room. We have conducted chi-square test, Fisher's exact test, t-test, ANOVA, and ANCOVA to compare the measured parameters in both groups. Results: The experimental group showed a significant elevation of mean arterial blood pressure, and mitigation of somnolence, sedation and dizziness compared to the control group. Conclusion: Leg raising and peripheral exercise is effective to expedite recovery in the patients who were applied with dexmedetomidine for their dental surgery.