• 제목/요약/키워드: Saturation effect

Search Result 1,035, Processing Time 0.035 seconds

Magnetic Saturation Effect of the Iron Core in Current Transformers Under Lightning Flow

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.97-102
    • /
    • 2017
  • A current transformer (CT) is a type of sensor that consists of a combination of electric and magnetic circuits, and it measures large ac currents. When a large amount of current flows into the primary winding, the alternating magnetic flux in the iron core induces an electromotive force in the secondary winding. The characteristics of a CT are determined by the iron core design because the iron core is saturated above a certain magnetic flux density. In particular, when a large current, such as a current surge, is input into a CT, the iron core becomes saturated and the induced electromotive force in the secondary winding fluctuates severely. Under these conditions, the CT no longer functions as a sensor. In this study, the characteristics of the secondary winding were investigated using the time-difference finite element method when a current surge was provided as an input. The CT was modeled as a two-dimensional analysis object using constraints, and the saturation characteristics of the iron core were evaluated using the Newton-Rhapson method. The results of the calculation were compared with the experimental data. The results of this study will prove useful in the designs of the iron core and the windings of CTs.

The study on the parallel operation of phase winding in the SR Drive for Electrical Vehicle Applications (전기자동차용 SRM의 상권선 병렬에 관한 연구)

  • Hong J.P.;Park S.J.;Won T.H.;Kwon S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.115-120
    • /
    • 2003
  • In a motor driving, the current rate is directly related to the rate of a switching device and in cost reduction, the parallel switching operation is the alternatives because it has the smaller current rate through current division. There are many investigations for the parallel switching operations to equaling the current division. However it remains many problems for practical usage. The reason is that the switching characteristics are mainly relied on the different saturation voltage of each device etc. and these factors are not altered by circuit designer. In order to compensate this problem, a proper resistance is experimently inserted to the switching device. But this method can not be the optimal solution. Therefore this paper proposes a new parallel operation which uses a parallel phase winding to remove the traditional effect of switching device such as saturation voltage according to the division of current. Also the reliable and stable driving is improved through experiments and the detailed principles.

  • PDF

A Study on the Factors Affecting the Strength of Alkali-Activated Slag Binders (알칼리 활성화 슬래그 결합재의 강도 발현 인자에 관한 연구)

  • Hwang, Byoung-Il;Kang, Suk-Pyo;Kim, Sang-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.2
    • /
    • pp.130-137
    • /
    • 2018
  • In the construction industry, research on alkali activated cement using fly ash or blast furnace slag fine powder has been published in Korea and abroad as a way to reuse industrial byproducts without using cement at all and to obtain economical effects at the same time. the purpose of this paper is to evaluate the effect of the ratio and coefficient of hydration ratio and lime saturation degree on the strength of alkali activated slag cement by chemical quantitative analysis of alkali activated slag cement used in the management of existing portland cement. as a result, it was confirmed that the ratio and coefficient of hydration ratio and lime saturation are all within a certain range.

The Development of Anti-Windup Scheme for Time Delay Control with Switching Action Using Integral Sliding Surface (적분형 슬라이딩 서피스를 이용한 TDCSA(Time Delay Control With Switching Action)의 와인드업 방지를 위한 기법의 개발)

  • Lee, Seong-Uk;Jang, Pyeong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1534-1544
    • /
    • 2002
  • The TDCSA(Time Delay Control with Switching Action) method, which consists of Time Delay Control(TDC) and a switching action of sliding mode control(SMC), has been proposed as a promising technique in the robust control area, where the plant has unknown dynamics with parameter variations and substantial disturbances are preset. When TDCSA is applied to the plant with saturation nonlinearity, however, the so-called windup phenomena are observed to arise, causing excessive overshoot and instability. The integral element of TDCSA and the saturation element of a plant cause the windup phenomena. There are two integral effects in TDCSA. One is the integral effect occurred by time delay estimation of TDC. Other is the integral term of an integral sliding surface. In order to solve this problem, we have proposed an anti-windup scheme method for TDCSA. The stability of the overall system has been proved for a class of nonlinear system. Experiment results show that the proposed method overcomes the windup problem of the TDCSA.

Electromagnetic Wave Absorbing Properties of FeSiCr and Fe50Ni Flaky Powder-Polymer Composite Sheet (FeSiCr에 Fe50Ni가 첨가된 폴리머 복합 시트의 전자파 흡수 특성)

  • Lee, Seok-Moon;Kim, Sang-Mun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.7
    • /
    • pp.462-467
    • /
    • 2014
  • In this paper, we studied the magnetic composite sheets for electromagnetic wave noise absorber of quasi-microwave band by using soft magnetic FeSiCr and Fe50Ni flakes with the thickness of about $1{\mu}m$ and polymer. The magnetic hysteresis curve including saturation magnetization and residual magnetization and the complex permeability characteristics of the composite sheets were investigated to clarify the mixing effect on electromagnetic wave absorption properties. The saturation magnetization was decreased about 10% while the residual magnetization was increased about 15% and the real parts of complex permeability at below 500 MHz were increased 0.6~4 while those values at above 500 MHz were decreased 0.4~2.5 according to the change of contents of FeSiCr and Fe50Ni powders. As a result, the reflection loss can be moved to the lower frequency from 2~3 GHz to 1~1.5 GHz as the contents of Fe50Ni flaky powder into FeSiCr flaky powder was increased up to 50%.

Core Loss Analysis of IPM Motor Considering Magnetic Saturation and Manufacturing of Electrical Steel (전기강판의 가공 및 포화를 고려한 IPM 모터의 철손 해석)

  • Ha, Kyung-Ho;Kim, Gi-Hyun;Kim, Jae-Kwan;Lee, Sun-Kwon;Na, Min-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.887.1_888.1
    • /
    • 2009
  • This paper proposes a core loss analysis method to obtain high accuracy prediction by using Multi-curve representing magnetic properties of a electrical steel in Finite Element Analysis (FEA). Generally, the magnetic prosperities of the electrical steel are measured by Epstein Method based on the international standards that are not good sufficient to predict motor performances. The method only aims to grade products in steel companies The magnetic properties of actual stator core is highly different to those given by steel companies due to the fact that stacking effect, shearing stress, nature anisotropy of electrical steels are not taken into account. In this paper, the magnetic properties are variously measured by three measuring devices, and then the several BH curves and BW curves obtained are used to analyze the core loss of a IPM. The BH curve in the high magnetic field are extrapolated using the mathematical formulation with the maximum saturation magnetic polarization measured

  • PDF

Sonication Effect on the Relative Permeability of contaminated Soil (초음파에 의한 오염토의 상대투수계수의 변화)

  • 김영욱
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This study investigated the effectiveness of ultrasonic waves on the relative permeability under a range of soil type, flushing rate, and sonication power. This study was conducted in the laboratory using a specially designed and fabricated equipment, and the laboratory study was simulated by ECLPISE 100 which is a commercial black oil simulator. The test results indicated the sonication increased contaminant extraction significantly. From analytical standpoint, sonication caused a change in the relative permeability of the test samples, a reduction in residual oil saturation and an increase in both irreducible water saturation and wettability. These three parameters are highly related with $(C_{10})^2$. The computer software ECLIPSE 100 can be used to analyze the change of the relative permeability due to sonication in two phase immiscible flow.

  • PDF

Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator (파일럿 규모 모의관로에서 부식성 수질제어 효과와 부식지수 모니터링)

  • Kim, Do-Hwan;Kim, Yung-Jin;Son, Hee-Jong;Ryou, Dong-Choon;Ahn, Jun-Young;Kim, Cheolyong;Hwang, In-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.183-192
    • /
    • 2018
  • Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.

The Effect of Dietary Phytate Content on Iron Absorption and Status in Young Korean Women

  • Kim, Ji-Hye;Li, Sun-Hee;Joung, Hyo-Jee;Paik, Hee-Young
    • International Journal of Human Ecology
    • /
    • v.4 no.1
    • /
    • pp.35-44
    • /
    • 2003
  • This study investigated the effects of dietary phyate reduction on the apparent absorption and biochemical parameters of iron status in young Korean women. Fourteen healthy, young women consumed low and high phytate diets for ten days of each experimental period. Duplicate diet samples, a fasting blood sample on day 9, and complete fecal samples for five consecutive days starting from day 5 of each diet period were collected. The iron content of diet and fecal samples were analyzed to calculate apparent absorption. Serum samples were analyzed for iron, ferritin, transferrin receptor and TIBC; transferrin saturation was also calculated. The apparent absorption of iron tended to increase in the low phytate period (32.51%) compared to the high phytate period (17.91%), but the difference was not significant (p=0.06). Serum ferritin decreased and serum transferrin receptor increased significantly during the low phytate diet although the mean values were within the normal range. Serum iron and transferrin saturation did not change significantly. In conclusion, the results indicated that reducing dietary phytate for ten days negatively affected iron nutritional parameters, but it moderately and positively affected apparent iron absorption in young Korean women. Further research on the long-term effects of a low phytate diet with an adequate iron content for vows Korean women is necessary.

Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube (수평관내의 $CO_2$의 증발 열전달에 관한 연구)

  • Jang, Seong-Il;Choi, Sun-Muk;Kim, Dae-Hui;Oh, Hoo-kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF