• 제목/요약/키워드: Saturation Temperature

검색결과 937건 처리시간 0.024초

온실재배 봄배추의 소비수량에 대한 고찰 (A Study on the Water Consumption of the Spring Chinese Cabbage in Greenhouse)

  • 윤용철;이종창;서원명;이근후
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.411-417
    • /
    • 1999
  • This study was performed to figure out an optimum water environment and to obtain the fundamental data related with saving labor and water consumption for the chinese cabbage being grown in greenhouse . The productivity of cabbage cultivated in boty pots and floor were compared to each other in the aspects of height and weight depending on the soil saturation levels. Obtained results are as follows. ; In case of pot cultivation , the height as well as weight of cabbage in 80% soil saturation level(P80) were measured to be larger than those in the other 2 soil saturation leves (P100 and P60). The weight of floor cultivated cabbages were relatively larger than that of pot cultivated ones. In accordance with saturation ration, the general trend of water consumption rate was maximum in P80 and was decreased in the order of P80 , P100 and P60. And the average indoor temperature as well as the plant growth rate were found to be closely related with water consumption rate.

  • PDF

Junction Temperature Prediction of IGBT Power Module Based on BP Neural Network

  • Wu, Junke;Zhou, Luowei;Du, Xiong;Sun, Pengju
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.970-977
    • /
    • 2014
  • In this paper, the artificial neural network is used to predict the junction temperature of the IGBT power module, by measuring the temperature sensitive electrical parameters (TSEP) of the module. An experiment circuit is built to measure saturation voltage drop and collector current under different temperature. In order to solve the nonlinear problem of TSEP approach as a junction temperature evaluation method, a Back Propagation (BP) neural network prediction model is established by using the Matlab. With the advantages of non-contact, high sensitivity, and without package open, the proposed method is also potentially promising for on-line junction temperature measurement. The Matlab simulation results show that BP neural network gives a more accuracy results, compared with the method of polynomial fitting.

두 개의 온도 의존 매개변수가 있는 3차 상태방정식의 성능비교 (Performance Comparison of Cubic Equations of State With Two Temperature Dependent Parameters)

  • 권영욱;박경근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.205-210
    • /
    • 2001
  • Cubic equations of state with two temperature dependent parameters are suggested and optimized using ASHRAE data for methane, propane, carbon dioxide, R-32 and R-134a. Appropriate simple functional forms are assumed for the temperature dependent parameters. The equations tested are Martin, Fuller, Harmens-Knapp, Schmidt-Wenzel. Among them modified Schmidt-Wenzel equation of state appears to be the choice for calculation of saturation properties such as vapor pressures, saturated liquid volumes, and saturated vapor volumes with an average absolute deviation of about one percent over the entire region excluding; the near cirtical.

  • PDF

DCCA 처리와 저온플라즈마 처리가 양모직물의 염색성에 미치는 영향 (Effect of Low Temperature Plasma and DCCA treatment on the Dyeing Properties of Wool Fabric)

  • 정영진
    • 한국염색가공학회지
    • /
    • 제20권4호
    • /
    • pp.53-59
    • /
    • 2008
  • For the modification of wool surface, wool fabrics treated with oxygen low-temperature plasma(LTP) and dichloroisocyanuric acid(DCCA) were dyed with milling type acid dye. The difference of dyeing properties on modified and control wool fabric were investigated. DCCA treated wool showed that saturation dye uptake and dyeing desorption ratio were higher than LTP treated wool. Dyeing transition temperatures of DCCA and LTP treated wool fabrics were 20$^{\circ}C$ degree lower than control wool fabric. In light color fastness test, DCCA treated wool fabric was 1 grade lower than LTP or control wool fabric.

Proposal of Potted Inductor with Enhanced Thermal Transfer for High Power Boost Converter in HEVs

  • You, Bong-Gi;Ko, Jeong-Min;Kim, Jun-Hyung;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1075-1080
    • /
    • 2015
  • A hybrid electric vehicle (HEV) powertrain has more than one energy source including a high-voltage electric battery. However, for a high voltage electric battery, the average current is relatively low for a given power level. Introduced to increase the voltage of a HEV battery, a compact, high-efficiency boost converter, sometimes called a step-up converter, is a dc-dc converter with an output voltage greater than its input voltage. The inductor occupies more than 30% of the total converter volume making it difficult to get high power density. The inductor should have the characteristics of good thermal stability, low weight, low losses and low EMI. In this paper, Mega Flux® was selected as the core material among potential core candidates. Different structured inductors with Mega Flux® were fabricated to compare the performance between the conventional air cooled and proposed potting structure. The proposed inductor has reduced the weight by 75% from 8.8kg to 2.18kg and the power density was increased from 15.6W/cc to 56.4W/cc compared with conventional inductor. To optimize the performance of proposed inductor, the potting materials with various thermal conductivities were investigated. Silicone with alumina was chosen as potting materials due to the high thermo-stable properties. The proposed inductors used potting material with thermal conductivities of 0.7W/m·K, 1.0W/m·K and 1.6W/m·K to analyze the thermal performance. Simulations of the proposed inductor were fulfilled in terms of magnetic flux saturation, leakage flux and temperature rise. The temperature rise and power efficiency were measured with the 40kW boost converter. Experimental results show that the proposed inductor reached the temperature saturation of 107℃ in 20 minutes. On the other hand, the temperature of conventional inductor rose by 138℃ without saturation. And the effect of thermal conductivity was verified as the highest thermal conductivity of potting materials leads to the lowest temperature saturations.

포화유무 및 온도조건에 따른 콘크리트 음향방출 신호 감쇠계수 결정 (Determination of acoustic emission signal attenuation coefficient of concrete according to dry, saturation, and temperature condition)

  • 이항로;홍창호;김진섭;김지원
    • 한국터널지하공간학회 논문집
    • /
    • 제24권1호
    • /
    • pp.39-55
    • /
    • 2022
  • 본 연구는 경주 중·저준위 지하 처분환경에서의 사일로 콘크리트의 음향방출(AE) 신호 감쇠계수(α)를 결정하기 위해 신호감쇠 실험을 수행하였다. 활용된 시료들은 경주 중·저준위 처분장 사일로에 사용된 콘크리트 배합비로 제작하였으며 28일간 수중 양생 후 처분환경에 맞도록 온도 및 포화유무에 따라 추가적으로 노출시켰다. 처분조건 별 각 3개씩의 공시체에 대하여 신호전달거리에 따른 AE 신호를 측정한 결과, 초기구간에서는 포화콘크리트의 AE 진폭과 절대에너지가 건조콘크리트의 경우보다 더 높게 나타났지만, α는 포화콘크리트의 경우가 더 높게 산정되었다. 또한, 포화유무와 상관없이 온도가 증가함에 따라 α는 감소하는 경향을 보였다. α는 온도조건보다는 포화유무에 따른 영향이 큰 것으로 분석되었으며, 이는 콘크리트 처분구조물의 감쇠신호 측정 시 포화여부를 고려한 판단이 중요하다는 것을 의미한다. 처분환경에서의 콘크리트 α는 균열이 발생한 위치에서의 실제 AE 특성 파라미터 값을 추정함으로써 경주 중·저준위 처분환경에서 사일로 콘크리트의 건전성을 예측하고 센서의 최적 배치를 결정하는 데 도움이 될 것으로 기대한다.

벽면충돌분무에 관한 수치해석 (A Study of Numerical Analysis on Wall Impinging Spray)

  • 염정국
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.21-28
    • /
    • 2013
  • Phenomenon of droplet impingement with high temperature wall needs to be investigated because atomization process of droplet and cooling process of the wall by the impingement are very important in industry, thus studies concerned with temperature of piston wall have been conducted in spray characteristics analysis of diesel engine. Hence, in this study, we defined $DT_{sat}(=T_w-T_{sat})$ superheat degree of the wall by difference between $T_w$ considering surface temperature of piston in the actual engine and $T_{sat}$ saturation temperature of the fuel and then investigated spray behavior of wall impinging with variance of the boiling process. In this study, in order to analyze wall impingement of droplet in accordance with difference of boiling condition, calculational conditions were set as $DT_{sat}=40K$(nucleate boiling), $DT_{sat}=140K$(transition boiling), and $DT_{sat}=240K$(film boiling). As a result, it can be found that fuel vapor increases and droplet mass decreases in the order of the nucleate boiling, transition boiling, and film boiling.

THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

  • Na, Young Su;Ha, Kwang Soon;Park, Rae-Joon;Park, Jong-Hwa;Cho, Song-Won
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.797-802
    • /
    • 2014
  • This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS) for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO) was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.

측정 온도 변화에 따른 백금실리사이드 정류성 접합의 파라미터 분석 (Parameter Analysis of Platinum Silicide Rectifier Junctions acceding to measurement Temperature Variations)

  • 장창덕;이용재
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1998년도 춘계종합학술대회
    • /
    • pp.405-408
    • /
    • 1998
  • 본 논문에서는, 백금 실리사이드와 실리콘 접합에서 n형 실리콘 기판의 농도와 온도 변화(상온, 55$^{\circ}C$, 75$^{\circ}C$)에 따라서 전류-전압 특성을 분석하였다. 측정한 전기적 파라미터들은 순방향 임계전압, 역방향 항복전압, 장벽높이(øbn), 포화전류, 이상인자와 동적저항의 변화이다. 결과로써, 기판 농도의 변화에 따라서는 순방향 임계전압, 역방향 항복전압, 장벽 높이, 동적저항은 감소하였으나 포화전류와 이상인자는 증가하였다. 온도 변화에 따라서는 역방향 항복전압과 동적저항이 증가하였다.

  • PDF