• Title/Summary/Keyword: Sand addition

Search Result 695, Processing Time 0.027 seconds

Applicability of Ferro-nickel Slag Sand for Dry Mortar in Floor (페로니켈슬래그 잔골재의 바닥용 건조모르타르 적용성 평가)

  • Cho, Bong-Suk;Kim, Won-Ki;Hwang, Yin-Seong;Koo, Kyung-Mo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.2
    • /
    • pp.105-112
    • /
    • 2019
  • Fine aggregate made of ferronickel slag(FNS) is similar to natural fine aggregates and is used in concrete structures both domestically and abroad, but its applications and research areas are limited. In this research, in order to expand the availability of FNS and improve the performance of cement mortar products, the applicability of FNS on dry mortar for floor was examined. Experimental results show that FNS improves flow of cement mortar because it has low absorption rate, spherical shape, and glassy surface. Also, the high stiffness of the FNS aggregate itself is considered to contribute to the improvement of cement mortar quality such as crack reduction by improving the compressive strength and shrinkage reducing. In addition, when FNS fine aggregate is applied, it was possible to secure the impact sound insulation performance equal to or higher than that of mortar using natural fine aggregate.

The Study on the Physical and Strength Properties of Lightweight Concrete by Replacement Ratio of Artificial Lightweight Aggregate (인공경량골재 혼합비율에 따른 경량 콘크리트의 물성 및 강도특성에 관한 연구)

  • Choi, Se-Jin;Kim, Do-Bin;Lee, Kyung-Su;Kim, Young-Uk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.4
    • /
    • pp.313-322
    • /
    • 2019
  • This study is to compare and analyze the physical and strength properties of lightweight concrete using domestic lightweight aggregate by replacement ratio of artificial lightweight fine and coarse aggregate after considering low cement mixture and pre-wetting time. The slump, unit weight, compressive strength and split tensile strength of lightweight concrete with domestic lightweight aggregate were measured. As test results, the slump of lightweight concrete by replacement ratio of lightweight fine aggregate increased as the replacement ratio of lightweight fine aggregate increased. The unit weight of lightweight concrete using 100% of lightweight fine aggregate was about 10.4% lower than that of the lightweight concrete with natural sand. In addition, the unit weight of lightweight concrete by replacement ratio of lightweight coarse aggregate increased with the increase of the ratio of LWG10(5~10mm). The compressive strength of lightweight concrete with lightweight fine and coarse aggregate increased as the replacement ratio of lightweight fine aggregate increased. The compressive strength of lightweight concrete with natural sand and LWG10 was 30 to 31MPa regardless of the replacement ratio of the lightweight coarse aggregate after 7 days.

Post-fire flexural behavior of functionally graded fiber-reinforced concrete containing rubber

  • Nematzadeh, Mahdi;Mousavi, Reza
    • Computers and Concrete
    • /
    • v.27 no.5
    • /
    • pp.417-435
    • /
    • 2021
  • The optimal distribution of steel fibers over different layers of concrete can be considered as an appropriate method in improving the structural performance and reducing the cost of fiber-reinforced concrete members. In addition, the use of waste tire rubber in concrete mixes, as one of the practical ways to address environmental problems, is highly significant. Thus, this study aimed to evaluate the flexural behavior of functionally graded steel fiber-reinforced concrete containing recycled tire crumb rubber, as a volume replacement of sand, after exposure to elevated temperatures. Little information is available in the literature regarding this subject. To achieve this goal, a set of 54 one-, two-, and three-layer concrete beam specimens with different fiber volume fractions (0, 0.25, 0.5, 1, and 1.25%), but the same overall fiber content, and different volume percentages of the waste tire rubber (0, 5, and 10%) were exposed to different temperatures (23, 300, and 600℃). Afterward, the parameters affecting the post-heating flexural performance of concrete, including flexural strength and stiffness, toughness, fracture energy, and load-deflection diagrams, along with the compressive strength and weight loss of concrete specimens, were evaluated. The results indicated that the flexural strength and stiffness of the three-layer concrete beams respectively increased by 10 and 7%, compared to the one-layer beam specimens with the same fiber content. However, the flexural performance of the two-layer beams was reduced relative to those with one layer and equal fiber content. Besides, the flexural strength, toughness, fracture energy, and stiffness were reduced by approximately 10% when a 10% of natural sand was replaced with tire rubber in the three-layer specimens compared to the corresponding beams without crumb rubber. Although the flexural properties of concrete specimens increased with increasing the temperature up to 300℃, these properties degraded significantly with elevating the temperature up to 600℃, leading to a sharp increase in the deflection at peak load.

Effects of Rice Koji Treatment and Salt Content on the Fermentation Characteristics of the Fish Sauce Made from the Pacific Sand Lance Ammodytes personatus (쌀코지 처리 및 식염함량이 동해안 까나리(Ammodytes personatus) 어간장의 발효특성에 미치는 영향)

  • Jung, Min-Jeong;Nam, Jong-Woong;Han, Ah-Ram;Kim, Gwang-Woo;Jeong, In-Hak;Kim, Byoung-Mok;Jun, Joon-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.3
    • /
    • pp.267-277
    • /
    • 2022
  • This study investigated changes in the physicochemical and microbiological properties of fermented fish sauces based on the pacific sand lance Ammodytes personatus during fermentation according to rice koji treatments and salt contents. In total, six fish sauces were prepared, with rice koji treatment for 24 or 72 h before salt addition, and salt contents of 10 or 20%, including two controls to compare the response to different salt contents without koji treatment. The initial pH values of the sauces with koji treatments were notably lower than those of the controls. Over the 10 months of fermentation, the amino nitrogen contents of the sauces with 10% salt were higher than those with 20% salt, while the volatile base nitrogen value was also increased. In the microbial community, the initial numbers of lactic acid bacteria and mold were higher in the sauces with koji treatment than in the controls. After 8 months of fermentation, the free amino acid and organic acid contents were higher in the sauces with koji treatment than in the controls. Although the fermentation rate was affected to a greater extent by salt contents, the rice koji treatment also exerted a positive effect on the acceleration of fermentation.

A parametric study of settlement and load transfer mechanism of piled raft due to adjacent excavation using 3D finite element analysis

  • Karira, Hemu;Kumar, Aneel;Hussain Ali, Tauha;Mangnejo, Dildar Ali;Mangi, Naeem
    • Geomechanics and Engineering
    • /
    • v.30 no.2
    • /
    • pp.169-185
    • /
    • 2022
  • The urbanization and increasing rate of population demands effective means of transportation system (basement and tunnels) as well as high-rise building (resting on piled foundation) for accommodation. Therefore, it unavoidable to construct basements (i.e., excavation) nearby piled foundation. Since the basement excavation inevitably induces soil movement and stress changes in the ground, it may cause differential settlements to nearby piled raft foundation. To understand settlement and load transfer mechanism in the piled raft due to excavation-induced stress release, numerical parametric studies are carried out in this study. The effects of excavation depths (i.e., formation level) relative to piled raft were investigated by simulating the excavation near the pile shaft (i.e., He/Lp=0.67), next to (He/Lp=1.00) and below the pile toe (He/Lp=1.33). In addition, effects of sand density and raft fixity condition were investigated. The computed results have revealed that the induced settlement, tilting, pile lateral movement and load transfer mechanism in the piled raft depends upon the embedded depth of the diaphragm wall. Additional settlement of the piled raft due to excavation can be account for apparent loss of load carrying capacity of the piled raft (ALPC). The highest apparent loss of piled raft capacity ALPC (on the account of induced piled raft settlement) of 50% was calculated in in case of He/Lp = 1.33. Furthermore, the induced settlement decreased with increasing the relative density from 30% to 90%. On the contrary, the tilting of the raft increases in denser ground. The larger bending moment and lateral force was induced at the piled heads in fixed and pinned raft condition.

Research on the factors affecting the development of shrinkage cracks of rammed earth buildings

  • Zhao, Xiang;Cai, Hengli;Zhou, Tiegang;Liu, Ling;Ding, Yijie
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.365-375
    • /
    • 2021
  • Rammed earth (RE) buildings have existed all over the world for thousands of years, and have gained increasing attention because of its sustainable advantages, however, the shrinkage cracks reduce its bearing capacity and seriously affect its durability and applicability. In this study, the shrinkage cracks test was carried out to investigate the effects of initial water content, proportion of sand and gravel, compaction degree, thickness and the additives (polypropylene fiber, cement and sodium silicate) of shrinkage cracks in RE buildings, ten groups of RE samples were prepared and dried outdoors to crack. Four quantitative parameters of geometrical structure of crack patterns were used to evaluate the development of cracks. The results show that the specimens cracking behavior and the geometrical structure of crack patterns are significantly influenced by these considered factors. The formation of crack can be accelerated with the increase of initial water content and thickness of specimen, while restricted with the increase of the compaction degree and the proportion of sand and gravel. Moreover, the addition of 1% polypropylene fiber, 10% cement and 0.5 volume ratio sodium silicate can significantly restrain the form and development of cracks. In RE construction, these factors should be considered comprehensively to prevent the harm caused by shrinkage cracks. Further works should be carried out to obtain the optimum dosage of the additives, which can benefit the construction of RE buildings in future.

Correlations between variables related to slope during rainfall and factor of safety and displacement by coupling analysis

  • Jeong-Yeon Yu;Jong-Won Woo;Kyung-Nam Kang;Ki-Il Song
    • Geomechanics and Engineering
    • /
    • v.33 no.1
    • /
    • pp.77-89
    • /
    • 2023
  • This study aims to establish the correlations between variables related to a slope during rainfall and factor of safety (FOS) and displacement using a coupling analysis method that is designed to consider both in rainfall conditions. With the recent development of measurement technologies, the approach of using the measurement data in the field has become easier. Particularly, they have been obtained in tests to determine the real-time safety and movement of a slope; however, a specific method has not been finalized. In addition, collected measurement data for recognizing the FOS and displacement in real-time with a specific relevance is difficult, and risks of uncertainty, such as in soil parameters and time, exist. In this study, the correlations between various slope-related variables (i.e., rainfall intensity, rainfall duration, angle of the slope, and mechanical properties including strength parameters of selected three types of soil; loamy sand, silt loam, sand) and the FOS and displacement are analyzed in order of seepage analysis, slope stability analysis and slope displacement analysis. Moreover, the methodology of coupling analysis is verified and a fundamental understanding of the factors that need to be considered in real-time observations is gained. The results show that the contributions of the abovementioned variables vary according to the soil type. Thus, the tendency of the displacement also differs by the soil type and variables but not same tendency with FOS. The friction angle and cohesion are negative while the rainfall duration and rainfall intensity are positive with the displacement. This suggests that understanding their correlations is necessary to determine the safety of a slope in real-time using displacement data. Additionally, databases considering rainfall conditions and a wide range of soil characteristics, including hydraulic and mechanical parameters, should be accumulated.

Evaluation of Applicability of CMD-SOIL using the Deep Mixing Method in Ulsan Area for the Construction of Coastal Structure Foundation (해안구조물 기초의 건설을 위해 울산지역에서의 심층혼합공법을 사용한 CMD-SOIL의 적용성 평가)

  • Jae-Hyun Park;Kwang-Wu Lee;Kyong-Ju Mun;Dae-Sung Cho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.3
    • /
    • pp.61-69
    • /
    • 2023
  • As global trade and maritime port environments change, the need to respond to larger and faster ships is increasing. Accordingly, new ports are being built around metropolitan cities such as Busan and Ulsan. In general, a compaction method using sand or gravel is applied to the construction of a new port. However, due to the lack of sand or gravel and the difficulty in securing economic feasibility due to the increase in unit price, the deep mixing method has recently been used. Therefore, in this study, CMD-SOIL using circulating resources was applied to the Ulsan area, and the applicability was determined by analyzing the laboratory mixing test and boring results at in-situ. As a result of the test, it was analyzed that it showed more than the design mixing strength, and it was possible to secure the similar performance as blast furnace slag cement. In addition, it was analyzed that the design standard strength can be sufficiently secured as a result of in-situ boring. Therefore, considering the field applicability in the Ulsan, it is judged that the use of CMD-SOIL is possible.

Evaluation of Dissipation Behavior of Excess Pore Pressure in Liquefied Sand Deposit Using Centrifuge Tests (원심모형실험을 이용한 액상화 모래지반의 과잉간극수압 소산거동 분석)

  • Kim Sung-Ryul;Ko Hon-Yim;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2006
  • Soil liquefaction occurs by complex dynamic interaction between soil particles and pore fluid. Therefore, experimental researches have been widely performed to analyze liquefaction phenomena. In this research, centrifuge tests were performed to analyze the liquefaction behavior of horizontal sand ground. Centrifugal acceleration was 40g and the thickness of model ground was 25cm, which simulates 10m thickness in prototype scale. Viscous fluid was used as pore fluid to remove the time scaling difference between dissipation and dynamic shaking. Test results showed that the dissipation of excess pore pressure is the combined behavior of solidification and consolidation. In addition, the solidification rate, the ground acceleration amplitude, and the dynamic permeability during solidification were influenced by the confining pressure.

Digital Image Analysis (DIA) for Estimating the Degree of Saturation of The Soil-Water Characteristic Curves (SWCC) (SWCC의 포화도를 구하기 위한 DIA 적용)

  • Min, Tuk-Ki;Huy, Phan Thieu
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.3
    • /
    • pp.53-63
    • /
    • 2008
  • The aim of this study was to validate the suitability of an digital image analysis (DIA) method to measure the degree of saturation in the unsaturated conditions. This study was carried out on the Joo-Mun-Jin standard sand. A one-dimensional sand column test was used in the constant water level condition to get the correlation equation between the color number ($C_n$) and the measured degree of saturation (5). In addition, the hanging wale. column technique to determine the soil-water charactenstic curve (SWCC) was performed in a Buchner funnel. The average degree of saturation ($S_{ave}$) in the SWCC could be obtained by substituting average color number at each suction head value with the $C_n\;-\;S$ correlation equation. Comparisons were made between the measured results by the hanging water column test and those obtained from DIA method. Results showed that the DIA method tested here provided fairly good saturation distribution values in the drying and wetting processes.