• Title/Summary/Keyword: Sampling Rate

Search Result 1,659, Processing Time 0.028 seconds

Filter- and Denuder-Based Organic Carbon Correction for Positive Sampling Artifacts

  • Hwang, InJo;Na, Kwangsam
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.107-113
    • /
    • 2017
  • This study describes (1) the impact of positive sampling artifacts caused by not only a filter-based sampling, but also a denuder-based sampling in the determination of particle-phase organic carbon (POC), (2) the effect of sample flow rate on positive artifacts, and (3) an optimum flow rate that provides a minimized negative sampling artifact for the denuder-based sampling method. To achieve the goals of this study, four different sampling media combinations were employed: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), (3) quartz filter and quartz filter behind Teflon filter (Q-QBT), and (4) quartz filter behind carbon-based denuder (Denuder-Q). The measurement of ambient POC was carried out in an urban area. In addition, to determine gas-phase OC (GOC) removal efficiency of the denuder, a Teflon filter and a quartz filter were deployed upstream and downstream of the denuder, respectively with varying sample flow rates: 5, 10, 20, and 30 LPM. It was found that Q-alone sampling configuration showed a higher POC than QBQ, Q-QBT, and Denuder-Q by 12%, 28%, and 23%, respectively at a sample flow rate of 20 LPM due to no correction for positive artifact caused by adsorption of GOC onto the filter. A lower quantity of GOC was collected from the backup quartz filter on QBQ than that from Q-QBT. This was because GOC was not in equilibrium with that adsorbed on the front quartz filter of QBQ during the sampling period. It is observed that the loss of particle number and mass across the denuder increases with decreasing sample flow rate. The contribution o f positive arti facts to POC decreased with increasing sample flow rate, showing 29%, 25%, and 22% for 10, 20, and 30 LPM, respectively. The 20 LPM turns out to be the optimum sample flow rate for both filter and denuder-based POC sampling.

Arbitrary Sampling Method for Nonlinearity Identification of Frequency Multipliers

  • Park, Young-Cheol;Yoon, Hoi-Jin
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.17-22
    • /
    • 2008
  • It is presented that sampling rates for behavioral modeling of quasi-memory less nonlinear devices can be far less than the Nyquist rate of the input signal. Although it has been believed that the sampling rate of nonlinear device modeling should be at least the Nyquist rate of the output signal, this paper suggests that far less than the Nyquist rate of the input signal can be applied to the modeling of quasi-memoryless nonlinear devices, such as frequency multipliers. To verify, a QPSK signal at 820 MHz were applied to a frequency tripler, whereby the device can be utilized as an up-converting mixer into 2.46 GHz with the aid of digital predistortion. AM-AM, AM-PM and PM-PM can be successfully measured regardless of sampling rates.

Design method of interpolation kernel using piecewise $\textit{n}$ th polynomials

  • Honma, Akihiro;Aikawa, Naoyuki
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.694-697
    • /
    • 2002
  • Sampling rate conversion widely used in subband coding, A/D and D/A transitions etc. is an important techniques. Nyquist filters and the filter banks have been used far the sampling converter. However, they need many memories and, whenever the sampling rate is changed it is necessary to redesign filters. Then we propose design method of the new interpolation kernel. Design method of the new interpolation kernel is approximated each piecewise of lowpass filter by n th polynomials. The proposed kernel is not redesigned, whenever the sampling rate is changed. The proposed kernel is a continuous function, the sampling rate of the rational number can be converted.

  • PDF

Variance estimation for distribution rate in stratified cluster sampling with missing values

  • Heo, Sunyeong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • Estimation of population proportion like the distribution rate of LED TV and the prevalence of a disease are often estimated based on survey sample data. Population proportion is generally considered as a special form of population mean. In complex sampling like stratified multistage sampling with unequal probability sampling, the denominator of mean may be random variable and it is estimated like ratio estimator. In this research, we examined the estimation of distribution rate based on stratified multistage sampling, and determined some numerical outcomes using stratified random sample data with about 25% of missing observations. In the data used for this research, the survey weight was determined by deterministic way. So, the weights are not random variable, and the population distribution rate and its variance estimator can be estimated like population mean estimation. When the weights are not random variable, if one estimates the variance of proportion estimator using ratio method, then the variances may be inflated. Therefore, in estimating variance for population proportion, we need to examine the structure of data and survey design before making any decision for estimation methods.

Novel Schemes to Optimize Sampling Rate for Compressed Sensing

  • Zhang, Yifan;Fu, Xuan;Zhang, Qixun;Feng, Zhiyong;Liu, Xiaomin
    • Journal of Communications and Networks
    • /
    • v.17 no.5
    • /
    • pp.517-524
    • /
    • 2015
  • The fast and accurate spectrum sensing over an ultra-wide bandwidth is a big challenge for the radio environment cognition. Considering sparse signal feature, two novel compressed sensing schemes are proposed, which can reduce compressed sampling rate in contrast to the traditional scheme. One algorithm is dynamically adjusting compression ratio based on modulation recognition and identification of symbol rate, which can reduce compression ratio. Furthermore, without priori information of the modulation and symbol rate, another improved algorithm is proposed with the application potential in practice, which does not need to reconstruct the signals. The improved algorithm is divided into two stages, which are the approaching stage and the monitoring stage. The overall sampling rate can be dramatically reduced without the performance deterioration of the spectrum detection compared to the conventional static compressed sampling rate algorithm. Numerous results show that the proposed compressed sensing technique can reduce sampling rate by 35%, with an acceptable detection probability over 0.9.

Evaluation of Commercially Available Passive Samplers and Development of New Passive Samplers Part 2 : Development of New Passive Samplers (공기중 유기용제 농도 측정에 있어서 수동식 시료채취기의 성능평가 및 한국산 수동식 시료채취기의 개발에 관한 연구 제 2 부 : 한국산 수동식 시료채취기의 개발)

  • Paik, Nam Won;Kong, Sang Hui;Park, Jeong Im;Lee, Young Hwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.97-108
    • /
    • 1996
  • A new type of passive samplers were designed and produced by authors. After evaluating the quality of activated carbon by measuring recovery rate of organic vapors and steadiness of sampling rate, activated carbon with 30 - 35 mesh produced by Company S in Korea was selected. In each passive sampler, an amount of 400 mg of the activated carbon was filled in 25-mm cassette and covered by fixed screen (or wire screen with 100 mesh). In addition to the fixed screen, a wind screen (or wire screen with 300 mesh) was also attached at outer face. The sampling rate of the new Korean passive samplers was estimated Conclusions obtained in the study are as follows. 1. Sampling rates of the newly developed Korean passive samplers were affected by sampling time. For n-hexane, sampling rates of 15- and 60-minute samples were 70.92 and 37.45 ml/min, respectively. Sampling rate of both 200- and 450-minute samples was 25.96 ml/min. It is concluded that, when passive samplers are used for measuring organic vapors, samples be collected longer than 60 minutes. 2. Sampling rate of the passive samplers was also affected by airborne concentration of organic vapors. Lower sampling rates were determined at level of 1/2 threshold limit values (TLVs) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH). It is recommended that sampling rate of the passive samplers be obtained at site by measuring concentrations using both the NIOSH Method and passive samplers simultaneously. 3. When the passive samplers, which collected organic vapors, were exposed to clean air for five hours, there was no significant loss of organic vapors due to reverse diffusion. 4. When samples were stored at room temperature ($21.8{\pm}0.7^{\circ}C$) and refrigerator ($3.8{\pm}0.7^{\circ}C$), there was no significant difference in the accuracy of results. For trichloroethylene and n-hexane, accuracies were within 25 % at both temperatures until seven days. However, poor accuracy exceeding 25 % was indicated in toluene from the first day. It is recommended that samples be stored at freezing temperature below $0^{\circ}C$. 5. Sampling efficiency was significantly affected by direction of the passive samplers. Results of samplers facing wind and down, respectively, were compared. Lower amount of organic vapors were collected when the sampler was oriented down. It is recommended that, when air velocity is low in plants, the passive samplers be oriented to the wind. However, when air velocity is high, the passive samplers be oriented down.

  • PDF

Low-Sampling Rate UWB Channel Characterization and Synchronization

  • Maravic, Irena;Kusuma, Julius;Vetterli, Martin
    • Journal of Communications and Networks
    • /
    • v.5 no.4
    • /
    • pp.319-327
    • /
    • 2003
  • We consider the problem of low-sampling rate high-resolution channel estimation and timing for digital ultrawideband (UWB) receivers. We extend some of our recent results in sampling of certain classes of parametric non-bandlimited signals and develop a frequency domain method for channel estimation and synchronization in ultra-wideband systems, which uses sub-Nyquist uniform sampling and well-studied computational procedures. In particular, the proposed method can be used for identification of more realistic channel models, where different propagation paths undergo different frequency-selective fading. Moreover, we show that it is possible to obtain high-resolution estimates of all relevant channel parameters by sampling a received signal below the traditional Nyquist rate. Our approach leads to faster acquisition compared to current digital solutions, allows for slower A/D converters, and potentially reduces power consumption of digital UWB receivers significantly.

Development of an Evaluation Method for the Flow Rate Performance of Gas Sampling Pumps Using Adsorbent Tubes (흡착튜브를 이용한 가스상물질 채취용 펌프의 유량성능 평가방법)

  • Kim, Nam Hee;Song, Ho June;Kim, Ki Youn;Ma, Hye Lan;Yi, Gwang Yong;Jeong, Jee Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.201-207
    • /
    • 2014
  • Objectives: Flow rate stability is very important for obtaining reliable measurements. However there is no easily used method for checking whether the flow rate set at the initial stage is sustained during sampling. The purpose of this study was to develop a method to evaluate the flow rate performance of gas sampling pumps with adsorbents commonly used to sample gases. Materials and methods: We tested the back pressure of gas sampling pumps commonly used in Korea with adsorbents such as charcoal and silica tubes and attempted to discover the combination conditions of adsorbents in accordance with back pressure required by ISO standard 13137. Results: We found the combination of sampling adsorbents to be applicable to the pressure drop required by the ISO standard for evaluating flow rate stability under increasing pressure drop and long term (eight-hour) performance. Conclusions: This evaluation method of using a sampling media matrix for checking flow rate stability as proposed by this study could be a highly useful tool for determining the reliability of the performance pumps before sampling.

Determination of Biodegradation Rate on Dichlorvos and Methidathion (Dichlorvos와 methidathion의 생분해율의 측정)

  • Min, Kyung-Jin;Cha, Chun-Geun
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.36-43
    • /
    • 1999
  • The present study was performed to investigate biodegradation rate of dichlorvos and methidathion. In the biodegradation test of two pesticides by the modified river die-away method from June 17 to August 22, 1998, the biodegradation rate constants and half-life were determined in Nakdong(A) and Kumho River(B). Biodegradation rate of dichlorvos was 4.51% in A sampling point, 6.88% in B sampling point after 7 days. Biodegradation rate constants and half-life of dichlorvos were 0.0066 and 105 days in A sampling point, 0.0102 and 67.9 days in B sampling point, respectively. Biodegradation rate of methidathion was 23% in A sampling point, 36% in B sampling point after 7 days. Biodegradation rate constants and half-life of methidathion were 0.0377 and 18.4 days in A sampling point, 0.0641 and 10.8 days in B sampling point, respectively. Biodegradation rate of methidathion was faster than that of dichlorvos. This suggested that the difference in biodegradation of pesticides was due to difference in the water quality and standard plate counts in the Nackdong and Kumho Rivers. The result of correlation analysis between biodegradation rate constants of the pesticides and water quality(DO, BOD, SS, ABS, NH$_3$-N, and NO$_3$-N) showed significant correlation with BOD, SS and NH$_3$-N at the 5% significant level. A significant linear equation was obtained from regression analysis at the 5% significant level, whereas, dependent variables were BOD, SS and NH$_3$-N, and the biodegradation rate constant was independent variable. It is suggested that dichlorvos will be mainly degraded by hydrolysis, and for methidathion was both hydrolysis and biodegradation. A significant QSAR equation was obtained from regression analysis at the 10% significant level, whereas, dependent variable is biodegradation rate constants of BPMC, chlorothalonil, dichlorvos and methidathion, vapor pressures, partition coefficients and water solubilities of the pesticides are independent variables. Also, a significant linear equation was obtained from regression analysis at the 1% significant level, whereas, dependent variable is biodegradation rate constants of BPMC, chlorothalonil, dichlorvos and methidathion, hydrolysis rate constants of the pesticides are independent variables. It is suggested that the pesticides will be degraded by main degradation factor when the pesticides was affected both hydrolysis and biodegradation.

  • PDF

Dynamic displacement estimation by fusing biased high-sampling rate acceleration and low-sampling rate displacement measurements using two-stage Kalman estimator

  • Kim, Kiyoung;Choi, Jaemook;Koo, Gunhee;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • v.17 no.4
    • /
    • pp.647-667
    • /
    • 2016
  • In this paper, dynamic displacement is estimated with high accuracy by blending high-sampling rate acceleration data with low-sampling rate displacement measurement using a two-stage Kalman estimator. In Stage 1, the two-stage Kalman estimator first approximates dynamic displacement. Then, the estimator in Stage 2 estimates a bias with high accuracy and refines the displacement estimate from Stage 1. In the previous Kalman filter based displacement techniques, the estimation accuracy can deteriorate due to (1) the discontinuities produced when the estimate is adjusted by displacement measurement and (2) slow convergence at the beginning of estimation. To resolve these drawbacks, the previous techniques adopt smoothing techniques, which involve additional future measurements in the estimation. However, the smoothing techniques require more computational time and resources and hamper real-time estimation. The proposed technique addresses the drawbacks of the previous techniques without smoothing. The performance of the proposed technique is verified under various dynamic loading, sampling rate and noise level conditions via a series of numerical simulations and experiments. Its performance is also compared with those of the existing Kalman filter based techniques.