• Title/Summary/Keyword: Sampling Device

Search Result 272, Processing Time 0.028 seconds

Stochastic Optimal Control and Network Co-Design for Networked Control Systems

  • Ji, Kun;Kim, Won-Jong
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.5
    • /
    • pp.515-525
    • /
    • 2007
  • In this paper, we develop a co-design methodology of stochastic optimal controllers and network parameters that optimizes the overall quality of control (QoC) in networked control systems (NCSs). A new dynamic model for NCSs is provided. The relationship between the system stability and performance and the sampling frequency is investigated, and the analysis of co-design of control and network parameters is presented to determine the working range of the sampling frequency in an NCS. This optimal sampling frequency range is derived based on the system dynamics and the network characteristics such as data rate, time-delay upper bound, data-packet size, and device processing time. With the optimal sampling frequency, stochastic optimal controllers are designed to improve the overall QoC in an NCS. This co-design methodology is a useful rule of thumb to choose the network and control parameters for NCS implementation. The feasibility and effectiveness of this co-design methodology is verified experimentally by our NCS test bed, a ball magnetic-levitation (maglev) system.

Adaptive Cross-Device Gait Recognition Using a Mobile Accelerometer

  • Hoang, Thang;Nguyen, Thuc;Luong, Chuyen;Do, Son;Choi, Deokjai
    • Journal of Information Processing Systems
    • /
    • v.9 no.2
    • /
    • pp.333-348
    • /
    • 2013
  • Mobile authentication/identification has grown into a priority issue nowadays because of its existing outdated mechanisms, such as PINs or passwords. In this paper, we introduce gait recognition by using a mobile accelerometer as not only effective but also as an implicit identification model. Unlike previous works, the gait recognition only performs well with a particular mobile specification (e.g., a fixed sampling rate). Our work focuses on constructing a unique adaptive mechanism that could be independently deployed with the specification of mobile devices. To do this, the impact of the sampling rate on the preprocessing steps, such as noise elimination, data segmentation, and feature extraction, is examined in depth. Moreover, the degrees of agreement between the gait features that were extracted from two different mobiles, including both the Average Error Rate (AER) and Intra-class Correlation Coefficients (ICC), are assessed to evaluate the possibility of constructing a device-independent mechanism. We achieved the classification accuracy approximately $91.33{\pm}0.67%$ for both devices, which showed that it is feasible and reliable to construct adaptive cross-device gait recognition on a mobile phone.

Interpolation Technique to Improve the Accuracy of RR-interval in Portable ECG Device (휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발)

  • Lee, Eun-Mi;Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.316-320
    • /
    • 2010
  • HRV(Heart rate variability) analysis parameter is widely used as an index to evaluate the autonomic nervous system and cardiac function. For reliable HRV analysis, we need to acquire the accurate ECG signals. Most of commercially available portable ECG devices have low sampling rate because of low power consumption and small size issues, which make it difficult to measure RR-interval accurately. This study is to improve the accuracy of RR-interval by developing R-wave interpolation technique, based on the morphological characteristics of the QRS complex. When the developed method was applied to ECG obtained at 200 Hz and the results were compared with 1000 Hz reference device, the error range decreased by 1.33 times in sitting and by 2.38 times in cycling exercise. Therefore, the proposed interpolation technique is thought to be useful to improve the accuracy of R-R interval in the portable ECG device with low sampling rate.

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

  • El Hajj, Ihab I.;Wu, Howard;Reuss, Sarah;Randolph, Melissa;Harris, Akeem;Gromski, Mark A.;Al-Haddad, Mohammad
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.576-583
    • /
    • 2018
  • Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissue acquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguided sampling of solid lesions and compare it with the historical FNA technique. Methods: $Acquire^{(R)}$ 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtained using $Expect^{(R)}$ 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independently evaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantly lower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNA groups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNB group. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to those obtained by FNA, but with fewer passes.

EFFECT OF FEEDING PATTERN ON DIURNAL VARIATION IN FAECAL CHROMIC LEVEL WHEN USING CONTROLLED RELEASE DEVICES IN SHEEP

  • Lee, G.J.;Mortimer, S.I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.1
    • /
    • pp.79-83
    • /
    • 1991
  • Diurnal variation in faecal chromic oxide levels was estimated from 4 hourly faecal sampling of 56 wethers allotted to one of six different feeding patterns. Sampling occurred on days 6 and 7 (Period 1) after a controlled release device was administered, and was repeated on days 14 and 15 (Period 2) following re-randomisation of the wethers to the feeding patterns. Increasing the frequency of feeding tended to be associated with higher faecal chromic oxide levels (p < 0.05), particularly in wethers fed thrice daily at 8 hour intervals. There was no interaction between feeding pattern and period, sampling day or time within-day. There were significant period x time within-day (p < 0.05) and day x time within-day (p < 0.001) interactions, indicating that variation in faecal chromic oxide between sample times was not consistent. This implies that sampling at any time of day is unlikely to result in a biased estimate of pasture intake, providing sufficient samples are collected. Significant period (p < 0.001) and period x day (p < 0.01) effects were associated with slow faecal chromic oxide equilibration in period 1. Equilibration did not occur until after day 7, indicating a need for caution when commencing sampling.

Direct Shear Test of Undisturbed Weathered Residual Soils (불교란 풍화잔적토의 직접전단시험)

  • 오세붕;이영휘;정종혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.423-430
    • /
    • 1999
  • A weathered residual soil is a soil-like material derived from the in situ weathering and decomposition of rock which has not been transported from its original location. Undisturbed sampling of residual soils is extremely difficult, which has an important effect on investigating the strength and compression characteristics. Thus, a special undisturbed sampling device (direct shear box with shoe) was developed and undisturbed samples were successfully obtained for direct shear tests, Direct shear testing was conducted under unsoaked and soaked condition. As a result, the shear strength of soaked samples was less than that of unsoaked samples, and it was verified that direct shearing of undisturbed samples can evaluate reasonably the shear strength and the slope stability.

  • PDF

Development of a Distributed Multi-rate Motion Control System Using USB

  • Rhim, Sung-Soo;Lee, Soon-Geul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.753-757
    • /
    • 2004
  • This paper describes a PC-based distributed multi-rate realtime control system using USB protocol, which is developed as a general motion controller. The control system consists of two control programs: one running at 1 kHz sampling rate on a PC with Linux and another running at 10 kHz sampling rate on a remotely located motion control card called RASID (remote axis serial interface device). Two programs communicates through USB at every 1 msec. A USB communication driver is developed to ensured the 1 msec desired communication time. The main program running on the PC generates reference trajectory at 1 kHz and send it to the RASID through USB and RASIDs located near the motors gather the sensor information and execute the low-level control at 10 kHz. The USB-based connectivity reduces the wiring harness and eventually the manufacturing cost of the machine. The multi-rate nature of the developed system improves the control capability. The effect of sampling rate is analyzed and simulated.

  • PDF

Suggest on Standardization of Ecological Survey Methods in the Korean Watershed (한국연안에서의 해양생물 생태 조사방법 표준화)

  • 이재학
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Ecological methods were reviewed through reports such as environmental impact assessment and damage effect of fishery in the Korean watershed. Survey items in marine ecological field were included: phytoplankton, zooplankton, benthic animal, algae, adult fish, egg and juvenile of fish. A standardization of survey method in the field of community ecology was suggested to consider the convenience, Sequency in Use of device, accuracy of data collected from that. It is necessary that spatial data should be sufficiently acquired toy statistical analysis of biodiversity and spatial comparison. Quantitative sampling method must be inevitably adopted based nature of biota and geographical type of the survey area. The same sampling method can make the data compared spatially but can't be applicable in all area. Standardizing survey method should be by no means under certain restriction of study and would become different according to survey environments. The first thing is minutely understanding about ecological character of biota inhabiting in certain area, and then determining survey method.

Development of Direct Measurement Device for Alveolar Breath Carbon Monoxide

  • Jo, Wan-Kuen;Oh, Jee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E4
    • /
    • pp.181-190
    • /
    • 2002
  • A novel portable device for the direct measurement of alveolar breath carbon monoxide (CO) was developed. The major components of the device include a mouthpiece, non-rebreathing two-way valve, Teflon tube, and CO dosimeter. An alveolar CO measurement can be completed within 1.5 min when using the proposed device and measurement protocol. Measurements could be read to the nearest 0.1 ppm. Humidity did not influence the CO measurements taken by the CO dosimeter, plus there were no problems associated with the recovery and carryover of CO through the device. The criterion for significance in statistical analyses was p< 0.05. The average recovery was 103 and 99% for recovery and carryover experiments, respectively. Test results using the proposed alveolar CO measurement system reflected a good reproducibility. This reproducibility was also supported by the finding that the relative standard deviations (RSDs) of the data sets were less than 7% for the loss experiment and less than 8% for the carryover experiment. Consequently, it would appear that the proposed device can be effectively applied to measure CO levels found in breath, thereby overcoming several disadvantages associated with the conventional bag and adsorbent tube sampling methods.