• Title/Summary/Keyword: Sampler

Search Result 879, Processing Time 0.026 seconds

Low-Power Block Filtering Architecture for Digital IF Down Sampler and Up Sampler (디지털 IF 다운 샘플러와 업 샘플러의 저전력 블록 필터링 아키텍처)

  • 장영범;김낙명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.743-750
    • /
    • 2000
  • In this paper, low-power block filtering architecture for digital If down sampler and up sampler is proposed. Software radio technology requires low power and cost effective digital If down and up sampler. Digital If down sampler and up sampler are accompanied with decimation filter and interpolation filter, respectively. In the proposed down sampler architecture, it is shown that the parallel and low-speed processing architecture can be produced by cancellation of inherent up sampler of block filter and down sampler. Proposed up sampler also utilizes cancellation of up sampler and inherent down sampler of block filtering structure. The proposed architecture is compared with the conventional polyphase architecture.

  • PDF

Development of Large Diameter Sampler and Analysis of Sampling Soil Character (대구경 샘플러의 개발 및 채취시료의 성질 분석)

  • 김영진;홍성완;김현민
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.353-360
    • /
    • 2000
  • We developed large diameter sampler (we called KICT type large diameter sampler) to obtain undisturbed clay and sand samples. In-situ test carried out in the In-Chon international airport and Kim-Hae. Also we obtained undisturbed sample with a hydraulic piston sampler in the nearly site and carried out unconfined compression test, consolidation test and triaxial test. The result, unconfined compression strength, secant modules, preconsolidation pressure and undrained shear strength of samples to obtain KICT type large diameter sampler are larger than that of samples to obtain hydraulic piston sampler. But failure strains and volume changes at the consolidation of samples to obtain KICT type large diameter sampler are smaller than that of samples to obtain hydraulic piston sampler

  • PDF

Application of KICT-type Large Diameter Sampler for Offshore Ground Sampling (KICT-type 대구경 샘플러의 해상 적용성 검토)

  • Kim, Young-Seok;Kim, Young-Chin;Yoon, Yeo-Won;Jeong, Ji-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1365-1369
    • /
    • 2008
  • A large diameter sampler (KICT-type large diameter sampler) was developed to take undisturbed samples from not only soft ground but also sandy and weathered ground. The KICT-type large diameter sampler was manufactured with the principle of triple core barrel sampling. In this study, the applicability to offshore ground sampling of the KICT-type large diameter sampler was confirmed at Inchoen Port construction site. And, in order to compare the quality of samples taken by the sampler with that of the traditional piston sampler, a series of laboratory tests were performed. From the test results, the samples taken by the KICT-type large diameter sampler showed higher quality than the traditional thin-walled tube samples.

  • PDF

Analysis of Soil Samples Obtained from Piston Sampler and Large Diameter Sampler (피스톤 샘플러와 대구경 샘플러를 이용한 시료 샘플의 공학적 분석)

  • Kim, Young Chin;Kang, Jae Mo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.29-34
    • /
    • 2008
  • A large diameter sampler was developed to take undisturbed samples from not only soft ground but also sandy and weathered ground. The large diameter sampler which was developed in Korea Institute of Construction Technology(KICT-type large diameter sampler) was manufactured based on the principle of triple core barrel sampling. A specially designed cutting device was used to cut and contain various kinds of samples in the sampler during a sampling and retrieval procedure. By adjusting the stiffness of the spring located at the top of the sampler, the distance between the cutting shoe and auger can be controlled in accordance with the ground condition. In order to investigate the applicability of the developed sampler and compare the quality of the samples taken by the sampler with that by the traditional thin-walled tube sampler, samples were taken at various sites according to the ground condition. And a series of laboratory tests such as the unconfined compress ion test, triaxial compression test, oedometer test, large diameter Rowe cell consolidation test (D: 150 mm) were performed. The test results showed that the samples by the KICT-type large diameter sampler show higher quality than the samples by the thin-walled tube sampler. And the validity and applicability of the developed KICT-type large diameter sampler was confirmed accordingly.

  • PDF

A Study on the Sample Characteristics Obtained from Large Diameter Sampler and Piston Sampler (피스톤 샘플러와 대구경 샘플러로 채취한 시료의 특성에 관한 연구)

  • Kim, Young-Chin;Kang, Jae-Mo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.3
    • /
    • pp.5-15
    • /
    • 2005
  • A large diameter sampler that can take undisturbed samples from soft ground was developed by KICT. In order to compare the quality of samples taken by the sampler with those of the traditional piston sampler, a series of laboratory tests were performed. Samples were taken at different sites such as Incheon, Gimhae, Yangsan and Busan. The results showed that the values of unconfined compression strength, secant modulus, pre-consolidation pressure, undrained shear strength, and shear modulus exhibited higher in samples taken by the large scale sampler. Strains at shear failure and volumetric strains were low for the new sampler. It was proved from the comparison that better quality samples could be obtained by the KICT sampler.

  • PDF

Junction, Circuit and System Developments for a High-Tc Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.13-15
    • /
    • 1999
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Junction, Circuit and System Developments for a High-$T_c$ Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.81-84
    • /
    • 2000
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Evaluation of Badge-Type Diffusive Sampler Performance for Measuring Indoor Formaldehyde

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Suntae
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • The purposes of this study were to determine the efficiency of using a badge-type diffusive sampler to measure formaldehyde concentrations indoors, and to evaluate the uncertainty associated with the use of data from a diffusive sampler. A diffusive sampler using 2,4-dinitrophenylhydrazine (DNPH) reagent was found to be a suitable tool for measuring the formaldehyde concentration in an indoor environment. The agreement between results of the diffusive sampler and DNPH cartridge were good, showing a correlation coefficient of 0.996. The sampling rate for the diffusive sampler was calculated to be 1.428 L $hr^{-1}$, with a standard deviation of 0.084 L $hr^{-1}$. It was found through analysis that the uncertainty associated with the sampling rate and the mass of the formaldehyde transported into the diffusive sampler by diffusion was the dominant contributor to the total.

Evaluation of Passive Sampler as a Useful Tool for Environmental Education (환경교육의 도구로서 간이 측정기의 활용에 관한 연구)

  • 전의찬;송민종
    • Hwankyungkyoyuk
    • /
    • v.11 no.2
    • /
    • pp.252-261
    • /
    • 1998
  • Since 1980's during which environmental pollution became serious enough to urge various types of environmental educations in many areas. But, most emphasis has been put on theoretical education. Even field education training mostly focused on water pollution. Therefore, simple air pollution monitoring system was needed for better field education in air pollution. In this study, we evaluated Passive Sampler as an useful tool for teaching air pollution in field. Students have found passive sampler very effective tool. Recent comparative study of auto-monitoring and passive sampler networks suggested a potential use of passive sampler as an useful tool for environmental education. In this study, the correlation between two sets of values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91 However, inexpensive Passive sampler with easy-to-operate colorimeter, has not been used in environmental education partially because large scale fluctuation in time and space characteristic to air pollution has been overlooked so that the sampler has not been tested for an effective educational tool. Passive sampler certainly deserves further in depth research as an effective air monitoring system, and better attention to its usefulness to teach students and public.

  • PDF

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS (공기 중 니코틴 포집에 있어 국산 확산포집기와 능동포집기의 비교 평가)

  • Kim, Hyo-Cher;Paik, Nam-Won;Lee, Kyung-Suk;Kim, Kyung-Ran;Kim, Won
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.485-491
    • /
    • 2006
  • It is widely known that Environmental Tobacco Smoke(ETS) is not good for health. ETS is composed of a lot of chemicals. So indicators are needed to evaluate the risk of ETS in air. One of the indicators is Nicotine. Active sampler has been used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. Sampling rate was 40.5 ml/min in exposure chamber. Experimental sampling rate (40.5 ml/min) was more than theoretical sampling rate (33.52 ml/min). And the higher was the concentration in air, the higher was experimental sampling rate. The average desorption, rate was 113.6%. The overall precision was 7.31 %. The overall accuracy was 18.96%, which were under NIOSH criteria. The average(GM) concentrations of nicotine by two sampling methods were $8.29{\mu}g/m^{3}$ (active sampler), $7.54{\mu}/m^{3}$ (diffusive sampler) in smoking area and smoking room. There was no regression between active sampler and diffusive sampler ($R^{2}=0.2397$). But slope, coefficient of determination was 1.017, 0.9292, respectively after removing outliers. And the slope (1.017) was close to the theoretical slope (1). In conclusion, this study indicated that diffusive sampler can be used to evaluate concentration of nicotine in air instead of active sampler.