• Title/Summary/Keyword: Sample testing

Search Result 986, Processing Time 0.022 seconds

Self-adaptive testing to determine sample size for flash memory solutions

  • Byun, Chul-Hoon;Jeon, Chang-Kyun;Lee, Taek;In, Hoh Peter
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.6
    • /
    • pp.2139-2151
    • /
    • 2014
  • Embedded system testing, especially long-term reliability testing, of flash memory solutions such as embedded multi-media card, secure digital card and solid-state drive involves strategic decision making related to test sample size to achieve high test coverage. The test sample size is the number of flash memory devices used in a test. Earlier, there were physical limitations on the testing period and the number of test devices that could be used. Hence, decisions regarding the sample size depended on the experience of human testers owing to the absence of well-defined standards. Moreover, a lack of understanding of the importance of the sample size resulted in field defects due to unexpected user scenarios. In worst cases, users finally detected these defects after several years. In this paper, we propose that a large number of potential field defects can be detected if an adequately large test sample size is used to target weak features during long-term reliability testing of flash memory solutions. In general, a larger test sample size yields better results. However, owing to the limited availability of physical resources, there is a limit on the test sample size that can be used. In this paper, we address this problem by proposing a self-adaptive reliability testing scheme to decide the sample size for effective long-term reliability testing.

A Bayesian Multiple Testing of Detecting Differentially Expressed Genes in Two-sample Comparison Problem

  • Oh Hyun-Sook;Yang Wan-Youn
    • Communications for Statistical Applications and Methods
    • /
    • v.13 no.1
    • /
    • pp.39-47
    • /
    • 2006
  • The Bayesian approach to multiple testing procedure for one sample testing problem proposed by Scott and Berger (2003) is extended to two-sample comparison problem in microarray experiments. The prior distribution of each gene's mean for one sample is given conditionally on the corresponding gene's mean for the other sample. Posterior distributions of interesting parameters are derived and estimated based on an importance sampling method. A simulated example is given for illustration.

Review and Derivation of Sample Size Determination for Hypothesis Testing and Interval Estimation (가설검정 및 구간추정에서 샘플크기 결정규칙의 고찰 및 유도)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.461-471
    • /
    • 2012
  • Most useful statistical techniques in six sigma DMAIC are hypothesis testing and interval estimation. So this paper reviews and derives sample size formula by considering significance level, power of detectability and effect difference. The quality practioners can effectively interpret the practical and statistical significance with the rational sample sizing.

  • PDF

Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna (생태독성 숙련도 시료의 적절성 평가)

  • Shin, Kisik;Park, Woosang;Lee, Jungseo;Yu, Soonju;Park, Taejin;Kim, Jongmin
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

CQI Activity for the reduction of inaquate testing sample (부적합 검체 감소를 위한 CQI 활동)

  • Cha, Sang-Yeol;Yun, Eun-Hui;Lee, In-Suk;Bae, Seong-Hun;Gang, Ju-Seok;Baek, Yeo-Hyeon
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.125-131
    • /
    • 2006
  • Background: Inadequate samples make laboratory tests delay cause errors, which will deteriorate the quality of the tests. Therefore, adequate samples are essential for reliable test result. To reduce the inadequate samples, they should to analyze problems and seek a way of improvement through CQI (Continuous Quality Improvement) activity. This will minimize errors during the test and produce a fast and accurate result. Eventrally, the qualily of entire test may be improved, and as a result, a good quality of medical care service may be provided. Methods: At first, inappropriate testing items were collected. Then, generating fctors and problems were investigated and analyzed in each case, In addition, the category with higher frequency wes primarily supervised. In consegalnce, a reduction of are dustion of improper testing sample was oxpected through continuous education and CQI activity. Conclusion : At the beginning of CQI activitv, the number of inadequate testing sample was of 8,591 total samples, which gives the frequency of 0.72%. As CQI activity was carried out the number of improper testing sample reduced to 58 out of 11,415 cases, which yields the frequency of 0,51%. One may notice the difference 0.2%. Among the inadequate sample(blood), there was a high frequency of hemolysis; thus, more of CQI activity is required for this specific matter. Because the occurrence of inadequate testing affects the clinical outcomes, it is extremely important that one manages each step of the procedure in collecting samples and mamtaines the quality of entire tests.

  • PDF

Developing of Exact Tests for Order-Restrictions in Categorical Data (범주형 자료에서 순서화된 대립가설 검정을 위한 정확검정의 개발)

  • Nam, Jusun;Kang, Seung-Ho
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.4
    • /
    • pp.595-610
    • /
    • 2013
  • Testing of order-restricted alternative hypothesis in $2{\times}k$ contingency tables can be applied to various fields of medicine, sociology, and business administration. Most testing methods have been developed based on a large sample theory. In the case of a small sample size or unbalanced sample size, the Type I error rate of the testing method (based on a large sample theory) is very different from the target point of 5%. In this paper, the exact testing method is introduced in regards to the testing of an order-restricted alternative hypothesis in categorical data (particularly if a small sample size or extreme unbalanced data). Power and exact p-value are calculated, respectively.

Likelihood Ratio Criterion for Testing Sphericity from a Multivariate Normal Sample with 2-step Monotone Missing Data Pattern

  • Choi, Byung-Jin
    • Communications for Statistical Applications and Methods
    • /
    • v.12 no.2
    • /
    • pp.473-481
    • /
    • 2005
  • The testing problem for sphericity structure of the covariance matrix in a multivariate normal distribution is introduced when there is a sample with 2-step monotone missing data pattern. The maximum likelihood method is described to estimate the parameters on the basis of the sample. Using these estimates, the likelihood ratio criterion for testing sphericity is derived.

Development of Asbestos Quality Control Sample for Proficiency Analytical Testing 1 - Development of Manufacturing Apparatus and Sample Preparing Procedure for Asbestos Quality Control Sample - (석면분석 정도관리용 표준시료 개발연구 I - 석면분석 정도관리용 표준시료 제조장치 개발 및 시료제조 방법 확립 -)

  • Yi, Gwang Yong;Lee, Jong- Han;Jung, Sijeong;Park, Doo Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.81-87
    • /
    • 2009
  • Final purpose of this study was designed to develop the quality control(QC) sample for proficiency analytical testing of asbestos. This study consisted of two parts; first, development of manufacturing apparatus and sample preparing procedure for asbestos quality control(QC) sample: second, validation of the QC samples made by our developed method as asbestos proficiency analytical testing sample. The main results of the first part research are as followed We developed the apparatus for manufacturing the asbestos QC sample, consisted of filter hold, filter holder manifolder, vacuum system, and vacuum pump. The most proper filter of making the QC samples was a cellulose ester membrane filter with 25 mm diameter, pore size 0.8 um. And we presented the optimal procedure for preparing the asbestos QC sample by using the developed apparatus. We will verify the manufactured asbestos QC samples by this method, and present the validation results to confirm the reliability as a asbestos QC sample in next paper.

A Study on Proficiency Test Sample Development for Environmental & Reliability Testing Field (환경 및 신뢰성 시험분야를 위한 숙련도시험 시료개발 연구)

  • PARK, Kyunghwan;LEE, Cheolgyu
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.447-462
    • /
    • 2017
  • Purpose: This study aims to develop distributable samples that can be used for proficiency testing to verify the ability of the testing laboratory to perform high temperature and low temperature tests. Method: In this study, the temperature-resistance characteristics of the NTC thermistor were used to develop samples. The homogeneity and stability of samples were examined according to the proficiency testing requirements. Results: Thirty samples with homogeneity and stability were developed and used for the proficiency testing. Thus, it was possible to distinguish between the test laboratories that showed satisfactory results and those that did not. Conclusion: It was the first time to develop samples that can be used for proficiency testing in high temperature and low temperature tests. and it was proved that the proficiency test program can be operated using the characteristics of NTC thermistor.

Sample Development for Quality Control of Formaldehyde and Proficiency Analytical Testing (정도관리용 포름알데히드 시료개발 및 분석능력평가)

  • Park, Hae Dong;Jang, Miyeon;Park, Seunghyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.58-66
    • /
    • 2020
  • Objectives: The objective of this study was to develop formaldehyde samples for quality control (QC) and to test the applicability of proficiency analytical testing in Korea. Methods: We made formaldehyde samples with certified standard solutions (formaldehyde in water or acetonitrile) and 2,4-dinitrophenylhydrazine (2,4-DNPH)-coated silicagel tubes. Four levels of formaldehyde concentration were tested for storage stability at room temperature and at 4℃ over three months. Analytical proficiency testing was performed with four or 36 institutes. Results: Formaldehyde sample tubes were easily made through the injection of standard solutions and the average efficiencies of recovery were 95-101%. The coefficients of variation (CV) of the formaldehyde samples were 1.39-2.55%. The recovery efficiencies fell between 90% and 110% at the concentration range of 1-10 ㎍/sample over three months storage at refrigerated and room temperature. The CVs were less than 5% in the proficiency analytical testing. By adjusted proficient ranges, 64% of the results of the second proficiency analytical testing were acceptable. Conclusions: The formaldehyde samples made by injection on 2,4-DNPH-coated silicagel tubes were stable and applicable for quality control.