• 제목/요약/키워드: Sample collection room

검색결과 24건 처리시간 0.032초

시료 채취 조건 및 검사방법에 따른 지하수내 섬유상 물질 검출 양상에 관한 연구 (Effect of Sampling and Analytical Methods on the Fibrous Materials from the Ground Water)

  • 김지용;김정란;정해관;임현술;백남원
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.209-222
    • /
    • 1997
  • Authors surveyed the ground water near the waste disposed from a fiberglass production factory to confirm the presence of glassfiber in the water and to determine the effect of sampling conditions and storage on the recovery of fibrous materials in the ground water. Sample was collected at every 4 hours for 48 hours consecutively. After finishing the 48 hours sample, water sampling was done from each tap after repeated turning on and off the water for 30 seconds at each time. Sample was collected in the two 1.5 liter polyethylene bottle after vigorously shaking the bottle with the same water several times with the flowing tap water. At each paired sample, one bottle was stored stand still at room temperature, and the other sample was filtered immediately after sampling. Water was filtered on the Mixed Cellulose Ester filter with negative pressure. Each sample was divided into upper and lower layer. The other bottle was stored at room temperature standstill for 7 days and filtered in the same fashion as the other pair of sample did. Each MCE filter was divided into 4 pieces and one piece was treated with acetone to make it transparent. Each prepared sample was observed by two researchers under the light and polarizing microscopy, scanning electron microscopy and energy dispersive X-ra microanalysis. Fibers were classified by the morphology and polarizing pattern under the polarizing microscope, and count was done. 1. There was a significant fluctuation in number of the fibers, but there was no specific demonstrable pattern. 2. Non-polarizing fibers frequently disappeared after 7 days's storage. But cluster of fibers were found at the wall of the same container by scratching technique. 3. Polarizing fibers were usually found in between the filter and the manicure pasted area. Possible explanations for this phenomenon will be that either these fibers are very light or have electronic polarity. Hence, these fibers are not able to be attached on the surface of slide glass. 4. Under the scanning electron microscopic examination, the fibers which are not refractive under the light microscopy were identified as glassfiber. Other fibers which is refractive under the polarizing microscopy were identified as magnesium silicate fibers. It is strongly suggested that development of standardized method of sample collection and measurement of fibrous material in the water is needed.

  • PDF

검체채취실의 고객만족도 향상 (Improvement for the Degree of Client Satisfaction in the Sample Collection Room)

  • 박연보;강희정;권흥만;안상진;양석환;태연주;진영희;조현구;이복자;구선회
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.222-232
    • /
    • 2004
  • The sample collection room(SCR) will have much more influence than all the other departments for the improvement of hospital image, if anyone coming to the SCR in the hospital goes back with the perfect complacency and because most clients who have much stresses and fatigues pay a final visit to the SCR via receipt-diagnosis- acceptance process. SCR has improved its image for the purpose of gratifying clients, in order for clients to visit the hospital again, the quality improvement(QI) team in the Diagnosis Inspection Medical Department has come to a conclusion as follows. The degree of client gratification before improvement marks 65.9 point, but the degree after improvement was 74.2 point. Therefore, satisfaction has increased by 8.3 points. The degree of client gratification in groups before improvement marks (1) service parts-89.2 points (2) facilities and environments-49.1 point (3) toilet facilities-46.3 point. But its gratification after improvement marks (1) 92.5 point (2) 60.1 point (3) 61.0 point. Therefore the degree of satisfaction has increased by (1) 3.3 point, (2) 11.0 point, (3) 14.7 point. The progress of facility improvement plans and the exclusion of improvement on the facility contents in the hospital have made facilities and environments of SCR and toilet facilities to be poorly improved. Although service parts have a good mark, and the facilities and environments are not scoring well, the whole degree clients' gratification of SCR couldn't be helped by the low grade. Therefore the bottom line for the clients' gratification of SCR in the future is to ameliorate the facilities and environments. SCR will take the clients' gratification survey every year and if any items get low marks, that is, below 90 point throughout the survey, SCR will immediately starts the improvement work for the clients' gratification with operating the programs of controlling quality continually, and SCR should induce the operation of services, participating in the kind campaign drive for clients. So SCR will adopt the incentive system for the best staff members who perform these kinds of services.

  • PDF

인터벤션실의 오염실태 분석 및 평가 (Analysis and Evaluation of Pathogen Contamination Status in Interventional Angiography Room)

  • 김경완;임인철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.233-239
    • /
    • 2022
  • In the radiology department, where radiation is used in medical institutions to perform examinations with various equipment, the field of surgical treatment is the intervention angiography room. Accordingly, strict infection control is required. The purpose of this study was to determine the contamination status by detecting pathogens before and after disinfection in the intervention angiography room, and to determine the degree of death by using a disinfectant, sodium dichloride isocyanurate, which is mainly used in the intervention angiography room. The subjects were 10 medical institutions of general hospital level or higher with an intervention angiography room in the P city, and 12 places with high contact frequency during examinations and procedures were sampled and requested to an analysis institution. As for the sample collection method, up/down, left/right directions were used to increase precision. Before disinfection, all procedures were completed, and after disinfection, exposure was performed using a disinfectant for at least 10 minutes, and detection was performed using a transport medium. As a result, in the pathogen analysis, most pathogens were detected in a humid environment or in a place with high contact frequency for microorganisms to thrive. The detected pathogens were found in the general environment or were human flora. It is a pathogen that does not cause disease under normal healthy host conditions. However, it was found to be an opportunistic infection that causes opportunistic infection depending on the case or situation in which the body's resistance is weakened. In addition, as a result of using the disinfectant mainly used in the intervention angiography room, it was found that more than 93.3% of them died. Therefore, the data of this study will be used as good basic data for the evaluation of pathogens in the intervention angiography room and will be of great help in infection control.

Delayed Deproteinization Causes Methodological Errors in Amino Acid Levels in Plasma Stored at Room Temperature or -20℃

  • Li, Junyou;Piao, Chunxiang;Jin, Huazi;Wongpanit, Kannika;Manabe, Noboru
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제22권12호
    • /
    • pp.1703-1708
    • /
    • 2009
  • Deproteinization has been recognized as a prerequisite for amino acid analysis of plasma samples. For plasma stored at room temperature, delaying deproteinization for 30, 60 or 120 minutes did not result in significant changes in the mean CV (coefficient of variation), which ranged from 4.4 to 5.6%. However the mean CV of aspartic acid, ${\alpha}$-aminoadipic acid, alanine and lysine was about 10%. When the plasma was stored frozen at -20${^{\circ}C}$, the CV was increased at 0 and 120 minutes after thawing, to 12.4% (range, 4.1 to 35.3%) and 8.0% (2.5 to 30.7%), respectively. The concentrations in plasma during storage at room temperature of all the amino acids analyzed showed significant changes. In plasma stored for 30 minutes at room temperature, 17 amino acids increased in concentrations and two decreased. Extending this period to 60 or 120 minutes increased the instability as compare to the reference group. Storing plasma at -20${^{\circ}C}$ for 2 weeks resulted in significantly greater changes in the amino acid concentrations than at room temperature. On extending the storage time at room temperature, after thawing, to 30, 60, and 120 minutes, 21, 20, and all 22 amino acids respectively changed significantly (p<0.01). The present study indicates that methodological errors occur in the concentrations determined for all amino acids when plasma is left at room temperature. The storage of frozen non-deproteinized plasma accompanied more significant changes in most amino acid concentrations and thus should be avoided. Deproteinization should be performed as soon as possible after plasma collection.

호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로 (A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room)

  • 윤형진;한수하
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제27권4호
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.

포장재에 따른 멸균품의 유효기간에 관한 연구 (Study on the Shelf Life of Sterilized Products according to Packaging Materials)

  • 장송자;정정희;최경미;김미영;박주희;정나연
    • 임상간호연구
    • /
    • 제25권3호
    • /
    • pp.333-341
    • /
    • 2019
  • Purpose: The purpose of this study was to determine the most appropriate shelf life for sterilized products according to their packaging material. Methods: Samples were prepared to target six nursing units in one general hospital in Seoul. After steam and E.O gas sterilization, sterilized product, samples were supplied to wards. Data collection was conducted for 3 months, after the expiration date of 3 months had passed for samples packaged with crepe paper and nonwoven wraps. For samples packaged with paper-plastic pouches, data collection conducted for 3 months when the expiration date of 9 months had passed. The sterilized products were collected and tested for microbial contamination. Identification of the storage environment was done as samples were collected. Results: This study confirmed that the storage environment met international standards such as CDC, except for temperature. For steam sterilized crepe paper packaging samples and steam and E.O gas sterilized for nonwoven packaging samples no contamination in all products was found for 3 months past the expiration date. However, in the E.O gas sterilized paper-plastic pouch packaging sterile samples, Gram-positive bacilli were detected in one sample from a surgical intensive care unit at 45 weeks and another sample from an operating room at 47 weeks. Furthermore, the results did not show any microorganisms for up to 52 weeks in all products. Conclusion: According to the results of this study, sterilized product packaging made with crepe paper and nonwoven wraps is better able an extended shelf life from 3 months to 6 months, reducing unnecessary costs.

DISCRIMINATION BETWEEN VIRGIN OLIVE OILS FROM CRETE AND THE PELOPONESE USING NEAR INFRARED TRANSFLECTANCE SPECTROSCOPY

  • Flynn, Stephen J.;Downey, Gerard
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1520-1520
    • /
    • 2001
  • Food adulteration is a serious consumer fraud and a potentially dangerous practice. Regulatory authorities and food processors require a rapid, non-destructive test to accurately confirm authenticity in a range of food products and raw materials. Olive oil is prime target for adulteration either on the basis of the processing treatments used for its extraction (extra virgin vs virgin vs ordinary oil) or its geographical origin (e.g. Greek vs Italian vs Spanish). As part of an investigation into this problem, some preliminary work focused on the ability of near infrared spectroscopy to discriminate between virgin olive oils from separate regions of the Mediterranean i. e. Crete and the Peloponese. A total of 46 oils were collected: 18 originated in Crete and 28 in the Peloponese. Oils were stored in a temperature-controlled room at 2$0^{\circ}C$ prior to spectral collection at room temperature (15-18$^{\circ}C$). Samples (approximately 0.5$m\ell$) were placed in the centre of the quartz window in a camlock reflectance cell; the gold-plated baking plate was then gently placed into the cell against the glass so as to minimize the formation of air bubbles. The rear of the camlock cell was then screwed into place producing a sample thickness of 0.5mm. Spectra were recorded between 400 and 2498nm at 2nm intervals on a NIR Systems 6500 scanning monochromator. Spectral collection took place over 2-3 days. Data were analysed using both WINISI and The Unscrambler software to investigate the possibility of discriminating between the oils from Crete and the Peloponese. A number of data pre-treatments were used and discriminant models were developed using discriminant PLS (WINISI & Unscrambler) and SIMCA (Unscrambler). Despite the small number of samples involved, a satisfactory discrimination between these two oil types was achieved. Graphical examination of principal component scores for each oil type also holds out the possibility of separating oils from either Crete and the Peloponese on the basis of districts within each region. These preliminary data suggest the potential of near infrared spectroscopy to act as a screening technique for the confirmation of geographic origin of extra virgin olive oils. The sample presentation strategy adopted uses only small volumes of material and produces high quality spectra.

  • PDF

유방촬영실에 근무하는 방사선사의 방사선 방어, 인식 및 태도에 관한 분석 (Analysis of Radiation Protection, Awareness and Attitude of Radiological Technologist in Mammography Room)

  • 홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.557-565
    • /
    • 2017
  • 본 연구는 유방촬영에 저에너지를 사용함으로써 방사선 피폭에 대한 인식이 저하될 것이라 사료되어 유방촬영실에 근무하는 방사선사들의 방사선 방어, 인식 및 태도에 대한 실태조사를 하였다. 자료 수집은 구조화된 설문지를 수정 보완하여 제주도를 제외한 6개 시도에 소재한 병원과 의원의 유방촬영실에 근무하는 방사선사 222명을 대상으로 하였다. 수집된 자료는 독립표본 t검정과 일원배치 분산분석을 실시하였다. 결과는 남자(p<0.05), 30대 이상의 연령(p<0.05), 기혼(p<0.05), 10년 이상의 근무경력(p<0.05), 8시간의 근무시간(p<0.01), 피폭체감(p<0.05)이 적을수록 방사선 방어에 대해 중요하게 인식하였고, 남자(p<0.05)이면서 피폭체감(p<0.01)이 많을수록 방사선에 대한 인식 및 태도가 높게 나타났다. 이는 유방촬영실의 근무 특이성과 근무환경에 영향을 받는 것으로 판단되며, 추후 다른 요인과의 분석을 통해 피폭에 대한 인식과 행위를 높이는데 기초자료가 되고자 한다.

용혈검체가 핵의학 검체검사 결과에 미치는 영향 (The Effect of Hemolysis sample on the Result of Nuclear Medicine Blood test)

  • 김진태;이종필;이수빈;김동민
    • 핵의학기술
    • /
    • 제25권1호
    • /
    • pp.41-43
    • /
    • 2021
  • 용혈 검체는 혈액검사 결과에 영향을 미치는 요인 중 하나이다. 핵의학 분야 또한 용혈 검체를 부적합검체를 분류하고 채혈실에 재 채혈을 요구하기도 한다. 이는 신속한 검사를 진행해야 하는 검사실 입장에선 장애 요소이기도 하다. 그러나 진단검사의학에서는 용혈이 각 검사 종목에 미치는 영향이 많이 알려진 반면, 핵의학에서는 용혈이 얼마나 검사 결과에 영향을 미치는지 실험을 통해 알려진 바가 없어 알아보고자 한다. 먼저, 19명의 환자에서 한 명당 각2개의 검체를 획득하고, 하나는 정상적인 혈청을 얻고, 다른 하나는 인위적으로 용혈 혈청을 획득했다. 그리고 각 종목별(AFP, CEA, PSA, CA-125, CA19-9, Thyroglobulin, Prolactin, E2, Insulin, T3, T4, TSH, FT4, TG-Ab, Anti-TPO, TBII, LH, FSH, Testosterone, PTH, DHEA-s, Cortisol, C-peptide)로 검사를 실시 한 후, 용혈검체와 정상 검체간의 결과값을 t-test를 통하여 통계적으로 유의성을 확인해 보았다. 실험 결과 키트 내 매뉴얼에 용혈검체를 사용하지 않도록 한 검사 종목 뿐만 아니라 대부분의 종목에서 용혈이 핵의학 검사결과에 영향을 미치지 않음을 알 수 있었다. 그러나, 인슐린과 C-peptide의 경우에는 용혈검체가 정상검체에 비해 통계적으로 유의하게 나타났다(P<0.05). 검체의 수가 적어 모든 검사 결과에 일반화 시킬 수는 없으나, 모든 용혈 검체를 부적합 검체로 간주하여 재채혈을 요구할 필요가 없음 또한 확인되었다. 그러므로 복잡한 핵의학 검사실의 접수 업무 개선에 도움이 될 것이라 생각된다.

COVID-19 팬데믹 상황에서 응급실 간호사의 소진에 영향을 미치는 융합적 요인 (Convergence factors Affecting Burnout of Emergency Room Nurses During the COVID-19 Pandemic)

  • 노승애;양승애
    • 사물인터넷융복합논문지
    • /
    • 제8권6호
    • /
    • pp.99-113
    • /
    • 2022
  • 본 연구는 응급실 간호사를 대상으로 COVID-19 대유행 상황에서 COVID-19 스트레스, 대인관계(보호자-환자) 스트레스, 감정노동이 소진에 미치는 영향을 파악하기 위한 서술적 조사 연구이다. 자료수집은 H 의료원 산하기관 5개 상급종합병원과 종합병원 응급실 간호사를 대상으로 2021년 12월 9일부터 12월 23일까지 시행되었다. 대상자의 일반적 특성과 직무 관련 특성, COVID-19 스트레스, 대인관계(보호자-환자) 스트레스, 감정노동, 소진을 측정하기 위해 자기기입식 설문지로 진행하였다. 수집된 자료는 SPSS/WIN 25.0 통계 프로그램을 이용하여 빈도 분석, 기술통계분석, Independent sample t-test, One-way ANOVA, Scheffé test, Correlation analysis, 다중회귀분석을 실시하였다. 응급실 간호사의 COVID-19 스트레스의 평균은 3.64점, 대인관계(보호자-환자) 스트레스 4.35점, 감정노동 3.38점, 소진 3.44점이었다. 일반적 특성 및 직무 관련 특성에 따른 간호사의 소진은 성별, 결혼상태, 총 임상 경력, 근무 기관 형태에 따라 유의한 차이를 보였다. 소진은 COVID-19 스트레스, 대인관계 스트레스, 감정노동과 모두 유의한 정적 상관관계를 보였다. COVID-19 팬데믹 상황에서 응급실 간호사의 소진에 영향을 미치는 융합적 요인으로는 근무 기관 형태 중 권역 응급의료센터, 지역응급의료센터, 대인관계 스트레스, COVID-19 스트레스, 성별로 나타났고 설명력은 28.6%로 나타났다. 이와 같은 결과를 통해 신종감염병 대유행 시점에서 응급실 간호사의 소진을 예방하고 간호업무성과를 높이기 위한 중재프로그램 개발을 위한 기초자료를 제공하고자 한다.