• Title/Summary/Keyword: Sample array

Search Result 204, Processing Time 0.034 seconds

Magnetic Interaction in FeCo Alloy Nanotube Array

  • Zhou, D.;Wang, T.;Zhu, M.G.;Guo, Z.H.;Li, W.;Li, F.S.
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.413-416
    • /
    • 2011
  • An array of FeCo nanotubes has been successfully fabricated in the pores of porous anodic aluminum oxide (AAO) templates by wetting templates method. The morphology and structure of the nanotube array were characterized by scanning electron microscopy, transmission electron microscopy and x-ray diffraction. The average diameter of the nanotubes was about 200 nm, and the length was more than 10 ${\mu}m$. Vibrating sample magnetometer and superconducting quantum interference device were used to investigate the magnetic properties of the nanotube array. Interaction between the nanotubes has been found to be demagnetizing as expected and the switching field distribution is broad.

On Line Monitoring and Diagnosis Technique for the Array of Photovoltaic Energy System (태양광 발전시스템 전지모듈의 온라인 감시 진단 시스템 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Byun, Sang-Zoon;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.168-172
    • /
    • 2007
  • The global environment deteriorating which originated from using of fossil fuel is an serious problem for human being to solve. The photovoltaic energy has been considered as a solution. In advanced countries, research and development for photovoltaic(PV) energy system is carrying on. Once installed, a PV array requires maintenance and fault diagnosis other than an occasional cleaning. In this research, the proposed system monitor and diagnosis the output of PV array by on-line for maintenance of PV power plant. The validity of proposed system is verified using sample system.

Laser Generation of Focused Lamb Waves

  • Jhang, Kyung-Young;Kim, Hong-Joon;Kim, Hyun-Mook;Ha, Job
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.637-642
    • /
    • 2002
  • An arc-shaped line array slit has been used for the laser generation of focused Lamb waves. The spatially expanded Nd:YAG pulse laser was illuminated through the arc-shaped line array slit on the surface of a sample plate to generate the Lamb waves of the same pattern as the slit. Then the generated Lamb waves were focused at the focal point of which distance from the slit position is dependent on the curvature of slit arc. The proposed method showed better spatial resolution than the conventional linear array slit in the detection of laser machined linear defect and drill machined circular defect on aluminum plates of 2mm thickness. Using the focused waves, we could detect the linear defect and the circular defect with the improvement of spatial resolution. The method can also be combined with the scanning mechanism to get an image just like by the scanning acoustic microscope(SAM).

Computationally Efficient Adaptive Beamforming Method Based on Interference Subspace Extraction (간섭 부공간 추출에 기초한 계산이 간단한 적응 빔 형성 기법)

  • Choi, Yang-Ho
    • Journal of Industrial Technology
    • /
    • v.31 no.B
    • /
    • pp.3-7
    • /
    • 2011
  • This paper addresses a computationally simple adaptive beamforming method to cancel interferences arriving onto a sensor array. In the proposed method, an estimate of the interference subspace is extracted from a submatrix of the sample covariance matrix and an orthonormal basis for the estimated subspace is efficiently found, one basis vector being updated every sample. Its computational burden is just $O(M{\eta})$ in an M-sensor array when ${\eta}$ directional signals are present. The new method does not make any premises of the geometrical structure of arrays, and can be applied to arbitrary arrays.

  • PDF

Implementation of unsupervised clustering methods for measurement gases using artificial olfactory sensing system (인공 후각 센싱 시스템을 이용한 측정 가스의 Unsupervised clustering 방법의 구현)

  • 최지혁;함유경;최찬석;김정도;변형기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.405-405
    • /
    • 2000
  • We designed the artificial olfactory sensing system (Electronic Nose) using MOS type sensor array fur recognizing and analyzing odour. The response of individual sensors of sensor array, each processing a slightly different response towards the sample volatiles, can provide enough information to discriminate between sample odours. In this paper, we applied clustering algorithm for dimension reduction, such as linear projection mapping (PCA method), nonlinear mapping (Sammon mapping method) and the combination of PCA and Sammon mapping having a better discriminating ability. The odours used are VOC (Volatile chemical compound) and Toxic gases.

  • PDF

Enhanced Cathodoluminescence of KOH-treated InGaN/GaN LEDs with Deep Nano-Hole Arrays

  • Doan, Manh-Ha;Lee, Jaejin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.283-287
    • /
    • 2014
  • Square lattice nano-hole arrays with diameters and periodicities of 200 and 500 nm, respectively, are fabricated on InGaN/GaN blue light emitting diodes (LEDs) using electron-beam lithography and inductively coupled plasma reactive ion etching processes. Cathodoluminescence (CL) investigations show that light emission intensity from the LEDs with the nano-hole arrays is enhanced compared to that from the planar sample. The CL intensity enhancement factor decreases when the nano-holes penetrate into the multiple quantum wells (MQWs) due to the plasma-induced damage and the residues. Wet chemical treatment using KOH solution is found to be an effective method for light extraction from the nano-patterned LEDs, especially, when the nano-holes penetrate into the MQWs. About 4-fold CL intensity enhancement factor is achieved by the KOH treatments after the dry etching for the sample with a 250-nm deep nano-hole array.

Development of process technique of the alumina membrane with nano-sized pore array (나노미터 크기의 미세구조물을 제작하기 위한 공정기술 개발)

  • Lee, J.H.;Lee, B.W.;Kim, C.K.;Lee, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1971-1973
    • /
    • 2005
  • We fabricated an alumina membrane with nano-sized pore array by anodic oxidation using the thin film aluminum deposited on silicon wafer. It is important that the sample prepared by metal deposition method has a flat aluminum surface and a good adhesion between the silicon wafer and the thin film aluminum. The oxidation time was controlled by observation of current variation. The nano-sized pores with diameter of $60{\sim}120nm$ was obtained by $40{\sim}80$ voltage. The pore widening process was employed for obtaining the flat surface because the pores of the alumina membrane prepared by the fixed voltage method shows the structure of rough surface. Finally, the sample was immersed to the phosphoric acid with 0.1M concentration to etching the barrier layer. The sample will be applied to electronic sensors, field emission display, and template for nano- structure.

  • PDF

Fabrication of the alumina membrane with nano-sized pore array using the thin film aluminum (박막 알루미늄을 이용한 나노미터 크기의 미세기공 형성)

  • Lee, Byoung-Wook;Lee, Jae-Hong;Lee, Eui-Sik;Kim, Chang-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.120-122
    • /
    • 2005
  • An alumina membrane with nano-sized pore array by anodic oxidation using thin film aluminum deposited on silicon wafer was fabricated. It is important that the sample prepared by metal deposition method has a flat aluminum surface and a good adhesion between the silicon wafer and the thin film aluminum. The oxidation time was controlled by observation of current variation. While the oxalic acid with 0.2M was used for low voltage anodization under 100V, the chromic acid with 0.1M was used for high voltage anodization over 100V. The nano-sized pores with diameter of 60~120nm was obtained by low voltage anodization of 40~90V and those of 200~300nm was obtained by high voltage anodization of 120~160V. Finally, the sample was immersed to the phosphoric acid with 0.1M concentration to etching the barrier layer. The sample will be applied to electronic sensors, field emission display, and template for nano-structure.

  • PDF

Control of Nanospacing in TiO2 Nanowire Array Using Electron Beam Lithography

  • Yun, Young-Shik;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.430.1-430.1
    • /
    • 2014
  • According to advanced nanotechnology in the field of biomedical engineering, many studies of the interaction between topography of surfaces and cellular responses have been focused on nanostructure. In order to investigate this interaction, it is essential to make well-controlled nanostructures. Electron beam lithography (EBL) have been considered the most typical processes to fabricate and control nano-scale patterns. In this work, $TiO_2$ nanowire array was fabricated with hybrid process (top-down and bottom-up processes). Nanodot arrays were patterned on the substrate by EBL process (top-down). In order to control the spacing between nanodots, we optimized the EBL process using Poly(methyl methacrylate) (PMMA) as an electron beam resist. Metal lift-off was used to transfer the spacing-controlled nanodots as a seed pattern of $TiO_2$ nanowire array. Au or Sn nanodots which play an important role for catalyst using Vapor-Liquid-Solid (VLS) method were patterned on the substrate through the lift-off process. Then, the sample was placed in the tube furnace and heated at the synthesis temperature. After heat treatment, $TiO_2$ nanowire array was fabricated from the nanodots through VLS method (bottom-up). These results of spacing-controlled nanowire arrays will be used to study the interaction between nanostructures and cellular responses in our next steps.

  • PDF

A Study on the Effectiveness of Averaged MUSIC Using Limited Number of Sensors (제한된 수의 Sensor를 이용한 Averaged MUSIC의 효율성에 관한 연구)

  • 김영집
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.206-209
    • /
    • 1993
  • The main purpose of this paper is to verify the effectiveness of a high resolution direction finding method, so called the‘averaged MUSIC’. This method uses a new sample array covariance matrix that consists of diagonal components obtained by taking averages of the diagonal component values of the sample covariance matrix for the MUSIC. The paper shows that the proposed method performs higher resolved direction-of-arrival estimation and better resolution probability than the MUSIC in such cases as low signal-to-noise ratio, when the number of sensors used is finite, based on the statistical analysis.

  • PDF