• Title/Summary/Keyword: Salt resistance

Search Result 603, Processing Time 0.035 seconds

Experimental Study on Development of Artificial Fishing Reefs Using Environment-Friendly Sulfur Concrete (환경친화적인 유황콘크리트 인공어초 개발을 위한 실험적 연구)

  • Park, Sung-Bae;Kim, Seok-Chel;Kim, Kyoung-Hoon;Hong, Chong-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.3 s.76
    • /
    • pp.58-64
    • /
    • 2007
  • New artificial fishing reefs are developed using modified sulfur concrete. Modified sulfur concrete, which is made of by-product aggregates and modified sulfur binder, has good properties, including high density, less water absorption, high strength, high salt resistance, and good affinity for living organisms. This paper shows the mechanical properties of modified sulfur concrete and its field tests under the sea. We have found that the pH-neutral materials attach microalgae and seaweed more readily, compared to the pH-high materials.

A Study Development of the Powder Metallurgy Method Using 400 Series Ferrite Stainless Steel ABS Sensor Ring (분말야금법을 이용한 400계열 페라이트 스테인레스강 ABS 센서 링 개발에 관한 연구)

  • 양현수
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.4
    • /
    • pp.197-208
    • /
    • 2000
  • ABS sensor ring has been manufactured by powder metallurgy (P/M) method using 400 series ferrite stainless steel. The results are following. It is supposedly sufficient to use for control computer due to good experimental results of magnetic characteristics. Compared with sensor ring made by iron, 400 series ferrite stainless steel has shown a good corrosion resistance without an addition surface treatment. Thus the decreasing production process has been obtained. As a result mechanical characteristics of hardness and tensile test, 400 series ferrite stainless steel shown a good endurance when it is combined to constant velocity joint(C/V), and has a good hardness properties endurable to sand and pebble impact. The products before sintering are much more corrodible in the condition of spray test of salt water and ammonia than humidity and nitrogen condition.

  • PDF

An Experimental Study on the Salt Resistance Properties with Concrete Materials under Marine Environment (해양환경에 노출시킨 콘크리트의 내염성능 평가)

  • Ko Jeong-Jae;Kim Young-Ung;Kim Dong-Chul;Shin Do-Chul;Kim Sang-Yong;Byun Dae-Bong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.790-793
    • /
    • 2004
  • The factors influencing concrete deterioration in marine environment can be generally divided into the physical and chemical action. The physical attack due to drying and wetting would increase the internal stress of concrete. The chemical attack resulting from the diffusion of ions$(i,e,\;Cl^-,SO_4^{2-},Mg^+)$ from seawater through the pores in concrete. The objective of this study is to evaluate corrosion characteristics of steel when using the various concrete materials under marine exposure environment. After 3 years of exposure, concrete specimen incorporating $40\%$ blast-furnace slag as replacement for type I cement with low w/c ratio of 0.42 and using the inhibitor shows excellent performance.

  • PDF

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System (접지시스템의 접속방식에 따른 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF

Characterization of Pediococcus pentosaceus Isolated from Porcine Intestine (돼지 장내로부터 분리된 항생제 저항성 Pediococcus pentosaceus의 특성)

  • Lee Mi-Sung;Yoon Ki-Hong
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.1
    • /
    • pp.74-77
    • /
    • 2006
  • A lactic acid bacterial strain resistant to several antibiotics such as oxytetracycline, tylosin, neomycin and sulfathiazole, which have been often used as a therapeutic agent in livestock, was isolated from the porcine gastrointestinal tract. The isolate YB-55 was identified as belonging to the genus Pediococcus with the highest similarity to P. pentosaceus on the basis of its 16S rRNA sequence and biochemical properties. The isolated strain showed viability of over 85% at pH 3.0 and was resistant to bile salt. The strain produced lactic acid of 12.3 g/L by jar fermentation and maintained its viability in the presence of antibiotics at dosage related therapeutic effect, suggesting P. pentosaceus YB-55 may of ffr potential as a probiotics for livestock.

A Study on the Characteristics of ELB Insulating Material deteriorated by Salt water (염수에 의해 열화된 누전차단기 절연재료의 특성에 관한 연구)

  • Kim, Hyung-Rae;Kim, Dong-Ook;Kim, Hyeog-Soo;Choi, Chung-Seog;Kim, Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.878-881
    • /
    • 2001
  • In this paper, we analyzed the characteristics of insulating material with ELB(earth leakage circuit breaker) through tracking experiment and the study was carried out three different types of samples. The tracking is breakdown phenomenon of material surface that is generated on the organic insulating material. The test method applied IEC publication 587. The result of the sample breakdown by tracking was carbonized and resistance of between the electrodes is approximately 300$\Omega$. In the result of DSC analysis, the caloric peak was detected before 100$^{\circ}C$ in product of tracking. It appeared weight loss of 10.87% at 537$^{\circ}C$ on TGA. IR spectrum analysis showed carbon-hydrogen(C-H)bond on molecular structure that is the sample of tracking.

  • PDF

Effect of the Salinity Level on Tracking Characteristics of Polymer Insulators (폴래머애자의 트래킹 특성에 미치는 염수농도의 영향)

  • 한재홍;송일근;김동명;정종욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.74-77
    • /
    • 2001
  • In order to investigate the effect of salinity level on tracking characteristics of polymer insulators for distribution power systems, tracking tests were performed by tracking wheel tester under different salt concentration. In this study, 6 kinds of polymer insulators were tested under 2200 ${\mu}\textrm{s}$/cm and 4000${\mu}\textrm{s}$/cm salinity. The salinity level has a significant effect on the tracking characteristics. Namely, most polymer insulators showed the good tracking resistance in case of low salinity level. But, in case of high salinity level some polymer insulators showed the excessive erosion and tracking. These phenomena may come from the different aging mechanism. It can be concluded that too high salinity level is not desirable in aging test of polymer insulators.

  • PDF

Development and Durability Characteristics of FRP Reinforcing Bar for Concrete Structures (콘크리트 보강용 FRP 리바의 개발 및 내구 특성)

  • Won, Jong-Pil;Park, Chan-Gi;Yoon, Jong-Han;Hwang, Kum-Sik;Cho, Yong-Jin
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.371-374
    • /
    • 2003
  • The corrosion of steel reinforcing bar(re-bar) has been the major cause of the reinforced concrete deterioration. FRP(Fiber-reinforced polymer) reinforcing bar has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. In this study, long-term durability performance of FRP re-bar were evaluated. The mechanical and durability properties of two type of CFRP- and GFRP re-bar were investigated; the FRP re-bars were subjected to alkaline solution, acid solution, salt solution and deionized water. The mechanical and durability properties were investigated by performing tensile and short beam tests. Experimental results confirmed the desirable resistance of FRP re-bar to aggressive chemical environment.

  • PDF