• 제목/요약/키워드: Saint

검색결과 531건 처리시간 0.03초

수술로써 치료한 일측성 상악동 병변 318예의 후향적 연구 (Unilateral Maxillary Sinus Lesion : A Retrospective Study of 318 Cases with Surgical Treatment)

  • 이호병;이상훈;문지승;박근형;구수권
    • 임상이비인후과
    • /
    • 제29권2호
    • /
    • pp.204-211
    • /
    • 2018
  • Background and Objectives : Unilateral maxillary sinus lesions are relatively common but may occur in variety of causes. Therefore, accurate diagnosis and appropriate treatment are needed. The aim of this study is to review patients with unilateral maxillary sinus lesion who underwent surgical treatment and to analyze causes and characteristics of unilateral maxillary sinus lesions with literature review. Materials and Methods : A retrospective chart analysis was completed on 318 patients with unilateral maxillary sinus lesions who underwent surgical treatment from January, 2008 through May, 2018. Clinical history and data such as age, sex, symptoms of initial, radiologic and dental finding, operation type were collected from medical record. Results : Patients mean age was 50.7 years with slight male gender dominance. Most common type was sinusitis (42.7%), followed by odontogenic sinusitis (22.3%) and fungal ball (19.5%). In particular, the most common cause of odontogenic sinusitis was post dental surgery such as implant. Middle meatal antrostomy (90.9%) was accounted for a great part of surgery underwent to patients. Patients complained of post nasal discharge (62.9%), nasal obstruction (40.9%) and odor smell(35.2%) most commonly. Periapical lucency (35.8%) was the most common in CT finding followed by implant perforation (17.3%) and oroantral fistula (12.3%) in odontogenic sinusitis. Conclusions : Unilateral maxillary sinus lesions are relatively common, but they are increasing recently with dental procedures such as implant surgery, and serious adverse effects due to malignant tumors or improper treatment may occur, so accurate diagnosis and treatment are needed.

Comparison of five international indices of adherence to the Mediterranean diet among healthy adults: similarities and differences

  • Aoun, Carla;Papazian, Tatiana;Helou, Khalil;El Osta, Nada;Khabbaz, Lydia Rabbaa
    • Nutrition Research and Practice
    • /
    • 제13권4호
    • /
    • pp.333-343
    • /
    • 2019
  • BACKGROUND/OBJECTIVES: To compare five indices of adherence to the Mediterranean Diet (MD) among adults living in the Mediterranean region. SUBJECTS/METHODS: A total of 100 healthy Lebanese adults aged between 18 and 65 years. Face-to-face interviews to collect sociodemographic and medical information, to take anthropometric measurements, and to fill a validated, culturally adapted, food frequency questionnaire (FFQ). The score for each item was calculated following the recommendations for each corresponding index. The five MD indices were Mediterranean Diet Scale (MDScale), Mediterranean Food Pattern (MFP), MD Score (MDS), Short Mediterranean Diet Questionnaire (SMDQ), and the MedDiet score. RESULTS: Significant correlations were detected between items with P-values < 0.001. Minimal agreement was seen between MDScale and MedDiet score and maximal agreement between MDS and MedDiet score. Univariate and multivariate analyses showed that MDS and MedDiet scores had significant correlations with fiber and olive oil intake, main components of the MD. MDScale showed a significant correlation with waist-to-hip ratio and with total energy intake but none of the five indices was correlated to body mass index (BMI). CONCLUSIONS: The indices that showed the highest correlation with variables related to the MD are the MDScale and the MedDiet score; therefore, they can be used to assess our future study populations. Based on the current results, more than half of the study population was non-adherent to the MD and adherence to this diet did not appear to protect against being overweight ($BMI{\geq}30$).

To Button or Not to Button? Primary Gastrostomy Tubes Offer No Significant Advantage Over Buttons

  • Osei, Hector;Munoz-Abraham, Armando Salim;Martino, Alice;Chatoorgoon, Kaveer;Greenspon, Jose;Fitzpatrick, Colleen;Villalona, Gustavo A.
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제25권3호
    • /
    • pp.211-217
    • /
    • 2022
  • Purpose: Outcomes between primary gastrostomy tubes and buttons (G-tube and G-button) have not been established in pediatric patients. We hypothesized that primary G-tube have decreased complications when compared to G-button. Methods: A retrospective review of surgically placed gastrostomy devices from 2010 to 2017 was performed. Data collected included demographics, outcomes and 90-day complications. We divided the patients into primary G-tube and primary G-button. Results: Of 265 patients, 142 (53.6%) were male. Median age and weight at the time of surgery were 7 months (interquartile range [IQR], 2-44 months) and 6.70 kg (IQR, 3.98-14.15 kg), respectively. Among the groups, G-tube had 80 patients (30.2%) while G-button 185 patients (69.8%). There were 153 patients with at least one overall complication within 90 days postoperative. There was no significant difference in overall complications between groups (G-tube 63.8% vs. G-button 55.7%, p=0.192). More importantly, there were no significant differences in major complications among the groups, G-tube vs. G-button (5% vs. 4%; p=0.455). Conclusion: Primary G-tube offers no significant advantage in overall, minor or major complications when compared to primary G-button.

Comparison of dimensional accuracy between direct-printed and thermoformed aligners

  • Koenig, Nickolas;Choi, Jin-Young;McCray, Julie;Hayes, Andrew;Schneider, Patricia;Kim, Ki Beom
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.249-257
    • /
    • 2022
  • Objective: The purpose of this study was to evaluate and compare the dimensional accuracy between thermoformed and direct-printed aligners. Methods: Three types of aligners were manufactured from the same reference standard tessellation language (STL) file: thermoformed aligners were manufactured using Zendura FLXTM (n = 12) and Essix ACETM (n = 12), and direct-printed aligners were printed using Tera HarzTM TC-85DAP 3D Printer UV Resin (n = 12). The teeth were not manipulated with any tooth-moving software in this study. The samples were sprayed with an opaque scanning spray, scanned, imported to Geomagic® Control XTM metrology software, and superimposed on the reference STL file by using the best-fit alignment algorithm. Distances between the aligner meshes and the reference STL file were measured at nine anatomical landmarks. Results: Mean absolute discrepancies in the Zendura FLXTM aligners ranged from 0.076 ± 0.057 mm to 0.260 ± 0.089 mm and those in the Essix ACETM aligners ranged from 0.188 ± 0.271 mm to 0.457 ± 0.350 mm, while in the direct-printed aligners, they ranged from 0.079 ± 0.054 mm to 0.224 ± 0.041 mm. Root mean square values, representing the overall trueness, ranged from 0.209 ± 0.094 mm for Essix ACETM, 0.188 ± 0.074 mm for Zendura FLXTM, and 0.140 ± 0.020 mm for the direct-printed aligners. Conclusions: This study showed greater trueness and precision of direct-printed aligners than thermoformed aligners.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.

Analysis of torsional-bending FGM beam by 3D Saint-Venant refined beam theory

  • Guendouz, Ilies;Khebizi, Mourad;Guenfoud, Hamza;Guenfoud, Mohamed;El Fatmi, Rached
    • Structural Engineering and Mechanics
    • /
    • 제84권3호
    • /
    • pp.423-435
    • /
    • 2022
  • In this article, we present torsion-bending analysis of a composite FGM beam with an open section, according to the advanced and refined theory of 1D / 3D beams based on the 3D Saint-Venant's solution and taking into account the edge effects. The (initially one-dimensional) model contains a set of three-dimensional (3D) displacement modes of the cross section, reflecting its 3D mechanical behaviour. The modes are taken into account depending on the mechanical characteristics and the geometrical form of the cross-section of the composite FGM beam. The model considered is implemented on the CSB (Cross-Section and Beam Analysis) software package. It is based on the RBT/SV theory (Refined Beam Theory on Saint-Venant principle) of FGM beams. The mechanical and physical characteristics of the FGM beam continuously vary, depending on a power-law distribution, across the thickness of the beam. We compare the numerical results obtained by the three-beam theories, namely: The Classical Beam Theory of Saint-Venant (Classical Beam Theory CBT), the theory of refined beams (Refined Beam Theory RBT), and the theory of refined beams, using the higher (high) modes of distortion of the cross-section (Refined Beam Theory using distorted modes RBTd). The results obtained confirm a clear difference between those obtained by the three models at the level of the supports. Further from the support, the results of RBT and RBTd are of the same order, whereas those of CBT remains far from those of higher-order theories. The 3D stresses, strains and displacements, obtained by the present study, reflect the 3D behaviour of FGM beams well, despite the initially 1D nature of the problem. A validation example also shows a very good agreement of the proposed models with other models (classical or higher-order beam theory) and Carrera Unified Formulation 1D-beam model with Lagrange Expansion functions (CUF-LE).

Acute Thrombotic Occlusion of Left Internal Jugular Vein Compressed by Bypass Graft for Thoracic Endovascular Aortic Repair Debranching Procedure

  • Sim, Hyung Tae;Beom, Min Sun;Kim, Sung Ryong;Ryu, Sang Wan
    • Journal of Chest Surgery
    • /
    • 제47권6호
    • /
    • pp.552-555
    • /
    • 2014
  • Thoracic endovascular aortic repair has become a widespread alternative treatment option for thoracic aortic aneurysm. The debranching of arch vessels may be required to provide an acceptable landing zone for an endovascular stent graft. We report a case where the bypass graft used in the thoracic endovascular aortic repair procedure compressed the left internal jugular vein, causing acute thrombotic occlusion.

Research on Culture of Costume in Coptic Paintings in Ancient Egypt - Based on Book Research -

  • Shin, Young-Sun
    • 패션비즈니스
    • /
    • 제5권5호
    • /
    • pp.36-48
    • /
    • 2001
  • The Christianity that spread to Egypt in 3rd century in A.D. is called Copt. Coptic Church built a lot of monasteries along the lower stream of Nile River, which produced thousands of text and paintings. Ethiopia is well known for its worship to Virgin Saint Mary and produced many paintings of Virgin Saint Mary in different costumes. The pictures usually came in foldable small books containing 3 pictures. The paintings usually featured Virgin Saint Mary and Jesus Christ dressed as royalty in crowns, saints and angels. There are saints on white horse, mirroring the oriental influence on Coptic painting. This research will look into the patterns and colours on the Coptic textiles, mainly tapestry.

  • PDF

Improvement of Si solar cell efficiency by using surface treatments on the antireflection coating layers and electrodes

  • Yang, Cheng;Ryu, Seung-Heon;Yoo, Won-Jong;Kim, Dong-Ho;Kim, Teak
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.202-203
    • /
    • 2009
  • Plasma etching was studied to obtain high-efficiency Si solar cells. SiN nanoparticles were observed upon the plasma treatment using SF6 gas. The mechanism of the nanoparticles formation has been studied. A net increase in the current density (Jsc) of the cells of $1.7mA/cm^2$ and in the conversion efficiency ($\eta$) of 2.1% is obtained after the plasma treatment for 10s, thanks to the significant decrease of reflection in the shorter wavelength range.

  • PDF

The Extraordinary Route of Chlorine Pre-Substitutional Doping on Graphene/Copper Substrate

  • Pham, Viet Phuong;Kim, Kyong Nam;Jeon, Min Hwan;Lin, Tai Zhe;Yeom, Geun Young
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.60-60
    • /
    • 2014
  • By the pre-doping technique on graphene/copper foil, we obtained the pristine sheet resistance and optical transmittance of the chlorine doped-single layer graphene $245{\Omega}/sq$ and 97% at 550 nm wavelength, respectively. X-ray photoelectron spectroscopy revealed that an extremely high Cl coverage of 47.3% of monolayer graphene surface was achieved as the highest surface-coverage graphene doping material ever reported.

  • PDF