• Title/Summary/Keyword: Safety voltage

Search Result 812, Processing Time 0.028 seconds

The Analysis on the Effect for Bus Voltage of Onsite Power System by Electrical Transient in Korea Standard Nuclear Power Plants (표준형원전 전기적 과도상태에 따른 소내 모선전압 영향 분석)

  • Kim, Moon-Young;Kim, Bok-Ryul;Cho, Young-Sik;Jang, Hong-Seok;Kim, In-Yong;Lee, Jae-Do
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.57-59
    • /
    • 2007
  • When onsite power is supplied from grid due to electrical transient in NPP, the effect of the nuclear plant risk will be increased by the change of grid performance. It is important to analyze the effect for bus voltage of onsite according to grid reliability. Therefore, we analytically accomplish the effect for bus voltage by electrical transient in KSNP.

  • PDF

Study of Touch and Step Voltages with Grounding Grid Using Electrolytic Tank and Analysis Program

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kill, Gyung-Suk
    • International Journal of Safety
    • /
    • v.9 no.2
    • /
    • pp.1-5
    • /
    • 2010
  • In order to analyze the potential rise of ground surface of grounding grid installed in buildings, the grounding simulator has been designed and fabricated as substantial and economical measures. This paper describes the study of touch and step voltages with grounding grid where earth leakage current is injected. To assess risk voltage of grounding grid, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of an electrolytic tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the touch voltage and step voltage above the grounding grid were very low, but were significantly increased near the edge of grounding grid.

Studies on Dynamic Responses of Nuclear Power Plant during Frequency and Voltage Decays (계통주파수 및 전압 저하시 원자력발전소 응동 분석)

  • Cho, Sung-Don;Kang, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1221-1223
    • /
    • 1999
  • The safety loads in a nuclear power plant perform a critical function to plant safety. The design of the electrical auxiliary system should ensure the availability and adequacy of the power supply, and therefore, the frequency and voltage relaying schemes should be installed on the system to monitor and protect against the degraded system condition. If unforeseen contingencies degrade the switchyard frequency and voltage to below the minimum values, the safety related bus should properly be transferred to alternate power source. This paper presents guidelines associated with the protection of nuclear power plants during frequency/voltage decay and the steady-state and dynamic analysis of auxiliary power system that should be performed to support the degraded voltage relay(second level undervoltage relay) setting.

  • PDF

A Study on Characteristics of a Volatage-Applied Electrostatic Reducer (전압인가식 제전기의 특성에 관한 연구)

  • 이동훈;정용철
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.77-83
    • /
    • 1995
  • An electrostatic reducer of a multi-pole high DC voltage applied type and a high frequency square wave voltage applied type have been studied to eliminate effectively and safely electrostatic charge on a dummy charged material. As a fundamental experiments, measurement were made on the decay time as a function of distance between electrostatic reducer and charged body, skewed angle of electrostatic reducer installed and wind speed of generated ions(+ or -) by electrostatic reducer with high DC voltage and high frequency square wave voltage. Based oil the results above, a appropriate installation and method were produced as a trial for factory.

  • PDF

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

Analysis of Properties of UV Corona on Insulator in Salt Water Environments (염수 환경 열화 상태를 모의한 절연애자의 자외선 코로나 특성 분석)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Lee, Myeong-Jun;Lee, Woo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1590-1591
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV camera. UV camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The UV camera was developed and measured using a UV image, as applied voltage increased ultraviolet images of the phenomenon could be obtained. And we investigated properties of UV corona image on insulator in salt water environments. From the results, the breakdown voltage was decreased and UV images were taken at low voltages and the UV image is rapidly increased with increasing High voltage.

  • PDF

Study of KMVSS for Hydrogen Fuel Cell Vehicle (수소연료전지자동차에 대한 안전기준 고찰)

  • Yong, Gee Joong;Lee, Kwang Bum;Kwon, Hae Boung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.6 no.2
    • /
    • pp.72-77
    • /
    • 2014
  • In the ongoing debates over the need to identify new sources of energy and to reduce the emissions of greenhouse gases. Hydrogen has emerged as one of the most promising alternatives due to its emissions from the vehicle being virtually zero. The governments have identified the development of regulations and standards as one of the key requirements for commercialization of hydrogen-fueled vehicles. Regulations and standards will helpful in overcoming technological barriers to commercialization. Developments of a technique for safety assessment of Hydrogen Fuel Cell Vehicle(HFCV) includes four tasks, research for regulation system and policy, hydrogen safety, vehicle operation safety and protection against high-voltage. The objective is to establish a technique for safety assessment and amend safety standards for HFCV and consequently reflect research results to vehicle management policy. We devised safety standards and evaluation techniques with regard to high-pressure gas and high voltage of hydrogen fuel cell vehicle. Korean Motor Vehicle Safety Standards(KMVSS) for HFCV was amended to June 10, 2014. including the results of the safety assessment technology for high-voltage and hydrogen characteristics.

Assessment System of Safety Level of High Voltage Electrical Facilities Considering Environmental Factors (환경영향 요소를 고려한 특고압 전기설비의 안전등급 평가시스템)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.249-254
    • /
    • 2017
  • This paper presents an assessment system of safety level of 22.9kV grade high voltage electrical facilities considering environmental factors. The assessment system was developed based on the following procedure. Firstly, assessment structure was determined by consulting standards regarding inspection and diagnosis of electrical facilities. Secondly, contents of items and sub items of assessment system were developed. Thirdly, in order to quantify the importance of the assessment system, the weight was calculated using Analytic Hierarchy Process(AHP). Lastly, assessment table of safety level was developed including environmental factors such as period of use and load factor. The developed system can evaluate the safety level of high voltage facilities in an objective way. Therefore it can be applicable to electrical safety management system based on Internet of Things(IoT).

A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility (침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구)

  • 김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.

Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

  • Tourab, Wafa;Babouri, Abdesselam
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.102-110
    • /
    • 2016
  • Background: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. Results: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.