• Title/Summary/Keyword: Safety of electricity

Search Result 308, Processing Time 0.036 seconds

Grope for Safety and Future Directions of School Electricity Facility (학교전기설비의 안전과 미래지향(未來指向) 모색(模索))

  • Jeon, Jun-Man;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.999-1001
    • /
    • 2005
  • School electricity facility is different to general electricity facility because use of immature students. But it was design, construct, manage of general electricity facility law realistically In this study, investigate the recent electrical accident data of school and the present status of electricity facility in Chonan. And grope for future directions of school electricity facility.

  • PDF

Restructuring of Technical Regulation in Korea Electricity Business Act (전기사업법상 기술기준 개편)

  • Kim, Han-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.223-226
    • /
    • 2004
  • The Technical Regulation in Korea Electricity Business Act, shall be obeyed for design, installation and maintenance of electric facilities to ensure public safety and reliable supply of electricity. The Technical Regulation will be a basis for securing electrical safety, and also will be a governmental criterion for judging acceptance of the electric facilities from a safety viewpoint.

  • PDF

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Bae, Suk-Myong;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.499-502
    • /
    • 2009
  • Supply of electric power and electricity safety for whole system and network are essential element. Electricity safety technology need rating for product and research about certification as product development that is done cotton flannel mixed with development of u-IT technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication and module for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in PD, Arc detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

  • PDF

Interference effect by electric utilities at electric resistivity Survey of fill dam (필댐의 전기비저항 탐사시 전기매체에 의한 영향 분석 연구)

  • Kim, Jae-Hong;Shin, Dong-Hoon;Im, En-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1037-1040
    • /
    • 2009
  • Using much most electricity electric resistivity survey by nondestructiveness inquiry enforcement design of country base equipment business and facilities preservation administration dimension electric resistivity survey sends and cause much effects in survey believability by electricity medium of survey personality survey contiguity that grasp base special quality by potential difference flowing current artificially in base. Is item that enforce in most in-suite although when make electric resistivity survey until present, electricity medium or effect research by electricity origination was gone much. There is shortcoming that must be difficult to know correct underground utilities establishment state in-suite in this research and do comparison examination running parallel drilling investigation to heighten believability of electric resistivity survey. Did to dam that censure data that regulate grading from construction and is censure construction which can know correctly interior base situation comparatively to electricity medium of interior and electricity eruption won of contiguity and base condition (base rock).

  • PDF

Domestic current situation and Improvement plan Consideration of Electricity Design & Supervision System (전기설계.감리제도의 합리적인 운영방안에 관한 고찰)

  • Jeong, Yeon-Hae;Nam, Ki-Beom;Sin, Hwa-Yeong;Jeong, Hyeong-Yong;Lee, Jong-Hyuk;Jun, Young-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.10-15
    • /
    • 2007
  • For the introduction of the electricity of the special design and supervision system to Protect the faulty-workmanship of the electricity equipment and to reserve the electricity safety, last 1995 "Electricity Technology Management Act" were carried out enactment. March 2002, we introduced the pre-Qualification system that is selected the competent company about the electricity design and supervision service over so much capacity which is ordered by the Public institution such as the nation, local autonomous entity, government investment institute and so on. December 2005, the electricity equipment over so much capacity was taken the housing construction plan's approval by the housing act in case, the municipal or district governor with the authority to approve who selected the electricity supervision company according to the pre-Qualification system. Due to the introduction of the system, we could expect the rights and interests increase of the consumer by eradicating dumping of the close relationship between supervision company and the builder, reduction and concurrent position of the supervisor, according to confirm the quality of the electricity equipment and electricity safety. In spite of introducing of the system, the problems occured as reducing the electricity designer's task range compared with different field, modifing the supervisor's rank system rationally, because of researching about the electricity design and supervision technique lacks. Also, KEEA(Korea Electric Engineers Association) manage the caller of the electricity design and supervisor(company or people), but the problems occured as opening to the public about the curler management, introducing automatic bidding system and We need the solution plan about this. Consequently, we consider the present situation of the domestic and outside and problem about the electricity design and supervision system in this paper, try to present rational operation plan through this.

  • PDF

A Study on Environmental Impact and Cost Analysis in Electricity Generation Using MFCA For a Coal-fired Power Plant (MFCA를 적용한 환경부하 및 발전원가 분석 연구 : 석탄화력발전소 중심으로)

  • Lim, Byung-Sun;Park, Seungwook
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.271-279
    • /
    • 2015
  • Global warming has pressured companies to put a greater emphasis on environment management which allows them to reduce environmental impact and costs of their operations. In Korea, the coal-fired power plants take a large account of electricity generation at 31.7% of the total electricity usage in 2014. Thus, environmental impact of coal-fired power plants is significant. This paper illustrated how to compute environmental impact and costs in electricity generation at a coal-fired power plant using MFCA methodology. Compared to the traditional accounting, an advantage of MFCA is to provide information on electricity generation costs and environmental wastes incurring throughout the production process of electricity. Based on MFCA, the coal-fired power plant was able to reduce production cost of electricity by 52.3%, and environmental wastes by 47.7%. As a result, MFCA seemed to be an effective tool in environmental management for power plants.

Derivation of Cause Variables necessary for Electrostatic Fire/Explosion Risk Assessment and Accident Investigation (정전기 화재·폭발 위험성평가 및 사고조사에 필요한 발생원인 변수 도출)

  • Junghwan Byeon;Hyeongon Park
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.9-21
    • /
    • 2024
  • Static-electricity-induced fires and explosions persistently occur every year, averaging approximately 80 and 20 cases annually according to fire statistics provided by the National Fire Agency and industrial accident statistics provided by the Ministry of Employment and Labor, respectively. Despite the relatively low probabilities of these accidents, their potential risks are high. Consequently, effective risk assessment methodologies and accident investigation strategies are essential for efficiently managing static-electricity hazards in fire- and explosion-prone areas. Accordingly, this study aimed to identify the causal variables essential for accident investigations, thereby facilitating risk assessments and the implementation of effective recurrence prevention measures to mitigate static-electricity hazards in fire-and explosion-prone regions. To this end, industrial accident statistics recorded over the past decade (2012 to 2021) by the Ministry of Employment and Labor were analyzed to identify major fire and explosion incidents and related industrial accidents wherein static electricity was identified as a potential ignition source. Subsequently, relevant investigation reports (63 cases) were thoroughly analyzed. Based on the results of this analysis, existing electrostatic fire and explosion risk assessment techniques were refined and augmented. Moreover, factors essential for investigating electrostatic fire and explosion disasters were delineated, and the primary causal variables necessary for effective risk assessments and scientific investigations were derived.

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

Analysis on Electric Shock Current in DC Electricity (직류환경에서 인체에 흐르는 감전전류 분석)

  • Lee, Jin-Sung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.254-259
    • /
    • 2016
  • Recently, DC distribution systems have become a hot issue because of the increase in digital loads and DC generation systems according to the expansion of renewable energy technologies. To obtain the practical usage of DC electricity, safety should be guaranteed. The main concerns for safety are twofold: one side is human protection against electric shocks, and the other is facility protection from short faults. "Effects of current on human beings and livestock" (IEC 60479) defines a human body impedance model in electric shock conditions that consists of resistive components and capacitive components. Although the human body impedance model properly works in AC electricity, it does not well match with the electric shock behavior in DC electricity. In this study, the contradiction of the human body impedance model defined by IEC 60479 in case of DC electricity is shown through experiments for the human body. From the analysis of experimental results, a novel unified human body impedance model in electric shock conditions is proposed. This model consists of resistive components, capacitive components, and an inductance component. The proposed human impedance model matches well for AC and DC electricity environments in simulation and experiment.