• 제목/요약/키워드: Safety of Structure

검색결과 4,478건 처리시간 0.027초

자동차 안전기준 체계 정비방안 연구 (A Study on Improvement Scheme for Korea's Motor Vehicle Safety Standards System)

  • 김규현
    • 자동차안전학회지
    • /
    • 제13권3호
    • /
    • pp.95-101
    • /
    • 2021
  • The Korea's safety standards for vehicle have been strengthened to reduce casualties from traffic accidents since 1962. The standards have a rather complicated structure. The safety standards are composed of the main text and asterisks, and the safety standard implementation rules are composed of the main text, asterisks and appendices, and items of the same name are stipulated in other chapters within the safety standards. This study is to suggest improvement measures such as simplifying the structure of these safety standards and integrating safety standard items with the same name. Through this, users' understanding of the standards will be improved, and it is expected that the system will be more efficient such as securing safety quickly through harmonization with international standards following the development of rapidly changing new technologies such as automated vehicles.

Full structure pseudo-dynamic test method and application based on OpenSees-OpenFresco-MTS

  • Zhen Tian;Yuan Cheng;Xuechong Ren;Mengmeng Yang
    • Structural Monitoring and Maintenance
    • /
    • 제11권3호
    • /
    • pp.173-185
    • /
    • 2024
  • Currently, the electro-hydraulic servo loading control system manufactured by MTS, OpenFresco hybrid test interface software and OpenSees finite element software are widely used in structure laboratories to carry out hybrid test, but there is no relevant public information about full structure pseudo-dynamic test based on the above software and hardware. In order to study the feasibility of using the above software and hardware to carry out full structure pseudo-dynamic test, the full structure pseudo-dynamic virtual experiments of a single degree of freedom (SDOF) structure and a two degrees of freedom (2DOFs) structure are carried out based on the MTS 793 Demo Mode, and the results are respectively compared with the finite element analysis method. The results show that the finite element analysis results and full structure pseudo-dynamic virtual experiment results are highly consistent, which verifies the feasibility of carrying out the full structure pseudo-dynamic test based on the above software and hardware. Then, a three story steel frame full structure pseudo-dynamic test is conducted, and the smooth implementation of full structure pseudo-dynamic test of the three story steel frame further verifies the reliability of thistesting method. The implementation method of carrying out the full structure pseudo-dynamic tests are introduced in detail, which can provide some reference for relevant research.

Shake table tests on a non-seismically detailed RC frame structure

  • Sharma, Akanshu;Reddy, G.R.;Vaze, K.K.
    • Structural Engineering and Mechanics
    • /
    • 제41권1호
    • /
    • pp.1-24
    • /
    • 2012
  • A reinforced concrete (RC) framed structure detailed according to non-seismic detailing provisions as per Indian Standard was tested on shake table under dynamic loads. The structure had 3 main storeys and an additional storey to simulate the footing to plinth level. In plan the structure was symmetric with 2 bays in each direction. In order to optimize the information obtained from the tests, tests were planned in three different stages. In the first stage, tests were done with masonry infill panels in one direction to obtain information on the stiffness increase due to addition of infill panels. In second stage, the infills were removed and tests were conducted on the structure without and with tuned liquid dampers (TLD) on the roof of the structure to investigate the effect of TLD on seismic response of the structure. In the third stage, tests were conducted on bare frame structure under biaxial time histories with gradually increasing peak ground acceleration (PGA) till failure. The simulated earthquakes represented low, moderate and severe seismic ground motions. The effects of masonry infill panels on dynamic characteristics of the structure, effectiveness of TLD in reducing the seismic response of structure and the failure patterns of non-seismically detailed structures, are clearly brought out. Details of design and similitude are also discussed.

닥트두께가 대향류 화염구조에 미치는 영향의 조사 (Investigation of Effects of Duct Thickness an Counterflow Flam Structure)

  • 박외철;고경찬
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.61-65
    • /
    • 2002
  • Nonpremixed counterflow flames at low strain rates, $ag=12s^{-1}$ and $12s^{-1}$, were numerically simulated to investigate the effects of the duct thickness on the flame structure in normal gravity. For small values of the duct thickness, the positions of the flame and stagnation point were highly sensitive to the duct thickness. When the duct thickness was greater than 6mm, however, the effects of the duct thickness on the flame structure were negligible. The computed temperature along the duct centerline agreed well with measurements.

파랑과 해안구조물과의 상호작용에 관한 연구 (The Study on the Wave Interaction Due to Offshore Structures)

  • 김성덕;이호진;도현승
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.139-145
    • /
    • 2009
  • The present study is to investigate the effect of wave-structure interaction such as wave oscillation. The theoretical method is based upon the linear diffraction theory obtained by the boundary element method. The water depth and incident wave period in fluid region are assumed to be constant. To investigate the wave interaction due to offshore structures, the numerical program has been developed and the simulation has been carried out by varying the conditions of distance and width of offshore structures. This study can effectively be utilized for safety assessment to various breakwater systems and layout of offshore breakwater in the ocean and coastal field. It can give information for the safety to construct offshore structure and revetment in coastal region.

구조물 안전진단에서의 GIS 활용방안 연구 (GIS application study in structure safety inspection)

  • 송석진;김나영;강인준
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2007년도 춘계학술발표회 논문집
    • /
    • pp.265-268
    • /
    • 2007
  • Structure safety inspection is executing periodically to apply with maintenance data of the structure. Because of the location of structure is appearing by measuring point and picture in the subway. It is difficult to track the accurate location of the inspected structure. Purpose of this paper is computerizing location and attribute of construction and searching efficiency by GIS.

  • PDF

제트 확산화염구조에 대한 FDS 연소모델의 예측성능 비교 연구 (A Comparison Study of the Prediction Performance of FDS Combustion Model for the Jet Diffusion Flame Structure)

  • 박은정;오창보
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.22-27
    • /
    • 2010
  • A prediction performance of Fire Dynamics Simulator(FDS) developed by NIST for the diffusion flame structure was validated with experimental results of a laminar slot jet diffusion flame. Two mixture fraction combustion models and two finite chemistry combustion models were used in the FDS simulation for the validation of the jet diffusion flame structure. In order to enhance the prediction performance of flame structure, DNS and radiation model was applied to the simulation. The reaction rates of the finite chemistry combustion models were appropriately adjusted to the diffusion flame. The mixture fraction combustion model predicted the diffusion flame structure reasonably. A 1-step finite chemistry combustion model cannot predict the flame structure well, but the simulation results of a 2-step model were in good agreement with those of experiment except $CO_2$ concentration. It was identified that the 2-step model can be used in the investigation of flame suppression limit with further adjustment of reaction rates

틸팅차량 언더프레임의 구조안전성 평가 (Evaluation for structural safety of TTX under structure)

  • 정종철;이상진;조세현
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.247-250
    • /
    • 2005
  • This study has evaluated the analysis results for the under structure of Korean tilting train(TTX). TTX has many equipments which are attached below the composite carbody. Loads due to equipments on the under structure are very complex and various types as operating condition. So applied loads are considered weight of equipments and acceleration. From the analysis, the structural safety of under structure was assessed.

  • PDF

복합기 커버 개폐용 힌지의 설계와 구조 해석 (Design and Structural Analysis on the Open and Close Hinge for Complex Machine)

  • 윤여권;양광모;김도석
    • 대한안전경영과학회지
    • /
    • 제14권2호
    • /
    • pp.49-54
    • /
    • 2012
  • As all kind of industry has developed, metal structure and machine instrument use bolt, pin, rivet and welding for assembly and combination. For pin and hinge, dimension accuracy is crucial to keep the operation and safety of the structure and machine instrument. In case of complex machine, the hinge for cover open-loop system is one of the significant design elements. Most of the hinges are being imported and assembled sine they give high technology development cost for its unit cost position. The reason is that the localization of hinge is inadequate. As the demand increase and the necessity of localization grow, it is now more important than ever to develop low cost structure. By the low cost structure, a new technology could be obtained for electronic product and structural hinge since it would enable for complex machine hinge to be guaranteed, technologically. Open-loop hinge is the link type and designed for the structure to keep constant open-loop. And, the hinge is examined in design stability by finite element analysis method. In this paper, the operation result is presented when the hinge for complex machine open-loop is designed for link type structure.

거셋일체형 센터필러 어퍼 루프레일 연결구조 개발 (Connection Structure Between Center Pillar and Roof Center Rail)

  • 이해훈;정필상;강종구
    • 자동차안전학회지
    • /
    • 제13권4호
    • /
    • pp.26-32
    • /
    • 2021
  • This study is intended to augment the Roof strength test being evaluated by IIHS (Insurance Institute for Highway Safety). In order to find solutions for increasing Roof Crashworthiness Evaluation SWR (Strengthto-weight ratio). This study introduces that Integrated Connection Structure Between Center Pillar and Roof Center Rail is proposed as a critical solution.