• Title/Summary/Keyword: Safety measurement

Search Result 2,491, Processing Time 0.04 seconds

Estimation of Uranium Particle Concentration in the Korean Peninsula Caused by North Korea's Uranium Enrichment Facility (북한 우라늄 농축시설로 인한 한반도에서의 공기중 우라늄 입자 농도 예측)

  • Kwak, Sung-Woo;Kang, Han-Byeol;Shin, Jung-Ki;Lee, Junghyun
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.127-133
    • /
    • 2014
  • North Korea's uranium enrichment facility is a matter of international concern. It is of particular alarming to South Korea with regard to the security and safety of the country. This situation requires continuous monitoring of the DPRK and emergency preparedness on the part of the ROK. To assess the detectability of an undeclared uranium enrichment plant in North Korea, uranium concentrations in the air at both a short and a long distance from the enrichment facility were estimated. $UF_6$ source terms were determined by using existing information on North Korean facility and data from the operation experience of enrichment plants from other countries. Using the calculated source terms, two atmospheric dispersion models (Gaussian Plume Model and HYSPLIT models) and meteorological data were used to estimate the uranium particle concentrations from the Yongbyon enrichment facility. A maximum uranium concentration and its location are dependent upon the meteorological conditions and the height of the UF6 release point. This study showed that the maximum uranium concentration around the enrichment facility was about $1.0{\times}10^{-7}g{\cdot}m^{-3}$. The location of the maximum concentration was within about 0.4 km of the facility. It has been assumed that the uranium sample of about a few micrograms (${\mu}g$) could be obtained; and that few micrograms of uranium can be easily measured with current measurement instruments. On the contrary, a uranium concentration at a distance of more than 100 kilometers from the enrichment facility was estimated to be about $1.0{\times}10^{-13}{\sim}1.0{\times}10^{-15}g{\cdot}m^{-3}$, which is less than back-ground level. Therefore, based on the results of our paper, an air sample taken within the vicinity of the Yongbyon enrichment facility could be used to determine as to whether or not North Korea is carrying out an undeclared nuclear program. However, the air samples taken at a longer distance of a few hundred kilometers would prove difficult in detecting a clandestine nuclear activities.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Study on the Single Oral Dose Toxicity of High Quality Rice Varieties (국내육성 벼 주요 품종의 Ethanol 추출물 단회 경구투여 안전성 연구)

  • Shin, Jin-Chul;Choi, Sung-Sook;Han, Hye-Kyoung;Chung, Ha-Sook
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.52 no.2
    • /
    • pp.146-152
    • /
    • 2007
  • The present study was carried out to investigate the potential acute toxicity of ethanol extracts of the aleurone layer of Oryza sativa cvs. Obongbyeo, Ilpumbyeo, and Aranghyangchalbyeo by a single oral dose in ICR mice. The test article was orally administered once by gavage to male and female mice at dose levels of 0, 2.5, 5.0, and 10.0 g/kg body weight (n=10 for male and female mice for each dose). We examined numbers of deaths, general signs, weight measurement and biochemical analysis for sexes and doses of mice control and experimental groups. All mice were alive during the experimental period so can not yield death rate and $LD_{50}$. Any significant clinical symptom was not observed in all treated groups. No significant body weight changes in treatment groups in comparison with those of control groups was observed at any dose levels in experimental groups. Plasma glucose levels were valued both control and treated groups and there were no significant differences between groups. The activities of ALT and AST were not increase in all sample treated groups when compared with the control groups. The results suggest that the toxicity of Oryza sativa cvs. Obongbyeo, Ilpumbyeo, and Aranghyangchalbyeo are low and its $LD_{50}$ is over 10.0 g/kg body weight in both male and female mice.

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).

Immunogenicity, Reactogenicity and Safety of a Combined DTPa-IPV Vaccine Compared with Separate DTPa and IPV Vaccines in Healthy Korean Infants (한국의 건강한 영아를 대상으로 DTPa-IPV 혼합백신을 접종한 경우와 DTPa 백신과 IPV 백신을 각각 투여하였을 경우의 면역원성, 반응원성 및 안전성)

  • Kim, Chang Hwi;Cha, Sung Ho;Shin, Son Moon;Kim, Chun Soo;Choi, Young Youn;Hong, Young Jin;Chey, Myoung Jae;Kim, Kwang Nam;Hur, Jae Kyun;Jo, Dae Sun;Kim, Sung Shin;Lee, Sang Lak;Song, Eun Song;Ramakrishnan, Gunasekaran;Ok, Jin Ju;Van Der Meeren, Olivier;Bock, Hans L.;Kim, Jung Soo
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.156-168
    • /
    • 2010
  • Purpose : To compare immunogenicity and reactogenicity of a combined diphtheria-tetanus-acellular pertussis-inactivated poliovirus vaccine (DTPa-IPV, $Infanrix^{TM}$ IPV, GlaxoSmithKline Biologicals) with co-administration of commercially available DTPa and IPV vaccines at separate injection sites (DTPa+IPV). Methods : A total of 458 infants aged 8-12 weeks were randomized to receive three-ose primary vaccination at 2, 4 and 6 months with DTPa-IPV or DTPa+IPV. Blood samples were collected pre and post vaccination for measurement of immune responses. Reactogenicity was assessed following each dose using diary cards. Results : One month post-dose 3, seroprotection rates for anti-diphtheria, anti-tetanus and anti-poliovirus types 1, 2 and 3 were ${\geq}99.5%$ and vaccine response rates to pertussis antigens were at least 98.6% in both DTPa-IPV and DTPa + IPV groups. Non-inferiority between the groups was demonstrated based on pre-defined statistical criteria. Incidences of both local and systemic symptoms were within the same range across both groups with grade 3 symptoms reported following no more than 4.3% of DTPa-IPV doses and 4.5% of DTPa + IPV doses. Two serious adverse events (both pyrexia) after DTPa-IPV administration were considered vaccine-related. Both infants recovered fully. Conclusion : Combined DTPa-IPV vaccine was immunogenic and well tolerated when used as a three-dose primary vaccination course in Korean infants. DTPa-IPV could be incorporated into the Korean vaccination schedule, reducing the number of injections required to complete primary immunization.

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty (경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구)

  • Lee, Jae-Heon;Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 2017
  • Percutaneous vertebroplasty (PVP) is increasingly used to treat osteoporotic vertebral fractures, myeloma and osteolytic vertebral metastases. The purpose of this study was to measure the absorbed radiation exposure dose and time during PVP and to assess the possibility of deterministic radiation effects to the operator and patient. The radiation dose and time measure by three pain physicians performed consecutive procedures using the twenty case PVP. Patient's dosimeter placed at the anteroposterior(AP) side was treatment of the vertebra body located in the upper level 2-3 and lateral(LAT) side was flank proximal to C-arm tube of back. Operator's dosimeter placed at the apron outside of upper sternum (thyroid), left chest, lower extremity and apron inside of left chest. Results: Radiation exposure times were $3.6{\pm}0.71min$. Measurements on the Patient radiation dose were AP $121.4{\pm}48.1{\mu}Sv$, LAT side $614.7{\pm}177.1{\mu}Sv$. Operator radiation dose were outside of the lead apron upper sternum $33.7{\pm}7.3{\mu}Sv$, outside of the lead apron chest $49.2{\pm}15.0{\mu}Sv$, outside of the lead apron lower extremity $12.8{\pm}3.8{\mu}Sv$ and inside of the lead apron chest $4.2{\pm}1.4{\mu}Sv$. To escape from the danger of radiation first long distance from the c-arm tube second exposure time reduced second lead apron used fluoroscopy during PVP is more safety patient and operation from the radiation exposure.

A Study on the Health Care Satisfaction and Attitude of Elementary School Students - by the presence or absence of nurse teacher - (초등학생의 보건관리 만족도와 태도에 관한 연구 - 양호교사 유무를 중심으로 -)

  • Park, Dong-Kwon;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.49-71
    • /
    • 2000
  • The purpose of this study was to serve as a basis for school health care of better quality, by making a comparative analysis of the health care satisfaction and attitude of elementary school students in consideration of their general characteristics and the presence or absence of nurse teacher. The subjects in this study were 919 selected six graders in 16 elementary schools in the city of Tongduchun, Koyang and Euijungbu, Yangju-kun and Yeunchun-kun. A survey was conducted with questionnaire designed for measurement of health care satisfaction and attitude. As a result of analyzing the data collected from June 1 through 15, 2000, the conclusions were as follows. 1) As for the general characteristics of the students investigated, the subjects included 513 boys(55.8%) and 406 girls(44.2%). The schools where 390(42.4%) students attended were located in municipal area, and the schools where 529(57.6%) students attended were located in kun area. 608(66.2%) students had a nurse teacher at their schools, while 311(33.8%) students had no nurse teacher. 498(54.2%) had an experience to use the health room this year, but 421(45.8%) had no such an experience. Their mean school life satisfaction was scored $3.42{\pm}.71$, above the average. And their health condition was rated $3.81{\pm}.87$, which implied they tended to be in good health. 2) The mean satisfaction at the health room operation was scored $3.33{\pm}.71$, above the medium level. What they were most satisfied with($4.02{\pm}1.08$) was, among the health room facilities, that there were beds. But they expressed the least satisfaction($2.83{\pm}1.17$) at the location of health room. The presence or absence of nurse teacher made a significant difference to their satisfactionat health room operation, because the students in schools with nurse teacher showed greater satisfaction($3.42{\pm}.72$) than the others in schools with no nurse teacher did($3.15{\pm}.66$). 3) Concerning their attitude to use the health room in case of disease or accident occurrence, a lot of students in schools with a nurse teacher, who had ever suffered from indigestion, headache or traumatic injury, used the health room. In schools with no nurse teacher, there was a tendency to talk to their class teachers(p<.001). The recognition of the necessity for health counseling was generally on a medium level. The counselor whom they wanted to discuss health problem with was family or friend in the largest cases. Few students discussed with class teachers in case there was a nurse teacher in school. Instead, some of them discussed with friend, family or nurse teacher, and there was a significant difference between them(p<.001). 4) The mean satisfaction at health, sanitation and environmental management was rated $3.20{\pm}.90$, above the average. The classroom lighting gave them the best satisfaction with $3.67{\pm}1.07$, but the satisfaction at toilet cleanness and disinfection was not good with $2.83{\pm}1.19$. By the presence or absence of nurse teacher, those who had a nurse teacher expressed better satisfaction at water supply facilities including hot water than the others who had no nurse teacher did(p<.001). But no significant difference was observed in the other items. 5) The health education satisfaction was rated $3.19{\pm}.99$, which was on a medium level. By item, the mean satisfaction level was $3.36{\pm}1.19$ at nurse teacher's explanation about treatment, $3.13{\pm}1.15$ at the frequency of health education, and $3.08{\pm}1.16$ at the explanation on the cause of disease. By the presence or absence of nurse teacher, the students with nurse teacher showed significantly better satisfaction at every factor0(p<.001). 6) Regarding health education attitude, their recognition of the need for school health education was scored $3.89{\pm}.96$. Those who had a nurse teacher felt it more necessary($3.96{\pm}.92$), yet the others who had no nurse teacher felt its necessity a little less($3.74{\pm}1.01$). The most preferred thing for them to learn in health education was first aid, followed by sex education, obesity prevention, safety accident prevention in school and outdoors, smoking-related health, good use of leisure time, and environmental pollution cause in the order named. According to the presence or absence of nurse teacher, there was a significant difference in sex education(p<.01), but no significant disparities were found in the other factors. The most preferred person who would offer health education was a lecturer from the outside(45.8%) and nurse teacher(45.4%). Their preference for class teacher as a person in charge of health education was just 8.8%. But the presence or absence of nurse teacher didn't produce any differences to their preference for a person in charge of health education.

  • PDF

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.