• Title/Summary/Keyword: Safety measurement

Search Result 2,491, Processing Time 0.033 seconds

The reliability test of a smart insole for gait analysis in stroke patients

  • Seo, Tae-Won;Lee, Jun-Young;Lee, Byoung-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.30-40
    • /
    • 2022
  • Background: This study analyzed the reliability of smart guides for gait analysis in patients with stroke. Design: Cross-sectional study. Methods: The participants of the study were 30 patients with stroke who could walk more than 10 m and had an MMSE-K test score of ≥24. Prior to the experiment, the subjects or their guardians entered their demographic characteristics including gender, age, height, weight into the prepared computer. The experiment was conducted in a quiet, comfortable, and independent location, and the patient was reminded of the equipment description, precautions, and safety rules for walking. A smart insole was inserted into the shoes of the patients and the shoes were put on before the patients walked three times on the 5-m gait analysis system mat installed in the laboratory. Results: The reliability of the equipment was compared with that of the gait analysis system, and the results of this study are as follows: among the gait analysis items, velocity had an ICC=0.982, the cadence had an ICC=0.905, the swing phase on the side of the gait cycle had an ICC=0.893, the swing phase on the side of the gait had an ICC=0.839, that on the non-affected side had an ICC=0.939, single support on the affected side had an ICC=0.812, and support on the non-affected side had an ICC=0.767. Conclusion: The results of this study indicate no statistical difference between the smart insole and the gait analysis system. Therefore, it is believed that real-time gait analysis through smart insole measurement could help patients in rehabilitation.

Risk Assessment of Micro and Emerging Contaminants in Domestic Effluent Environment: Targeting on 80 First-class substances assigned by Ministry of Environment (미량 및 신종유해물질의 국내 방류 환경에서의 위해성 평가: 환경부 지정 1순위 80종 대상으로)

  • Lee, Jai-Yeop;Park, Saerom;Kim, Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.501-509
    • /
    • 2021
  • In 2018, total 263 micro and emerging contaminants were selected as target substances by the Ministry of Environment, and 80 of them were first-class substance including endocrine disruptors, residual Pharmaceuticals and Personal Care Products (PPCPs), residual organic pollutants, pesticides and heavy metals. In this study, in order to evaluate the Hazard Quotient (HQ) of the 80 types in the domestic water environment the concentration of discharged effluent and nearby water environment reported by Korean institutes since 2010 was investigated. There were 45 substances reported to be detected, and Measurement Environment Concentration (MEC) were obtained by collectively converting them into water environment concentration. For biotoxicity, half maximal Effective Dose (EC50) to Daphnia magna, a water fleas species widely adopted in Material Safety Data Sheet (MSDS) was applied. As for the biotoxicity level, the Predicted No-Effect Concentration (PNEC) was obtained by applying the Assessment Factor (AF) and the HQ was derived by dividing it from the MEC. As a result of calculating the HQ, more than 1 substances were Cabamazepine, Mefenamic acid, Acetaminophen, Ibuprofen, Nonylphenol, Nickel, Erythromycin, Acetylslic acid, etc. Meanwhile, perfluorinated compounds were identified as hazardous substances in the water env ironment, with 5 out of 14 species included in the 20 ranks of first-class substance.

Analysis and Improvement Specific Frequency Reception Noise Phenomena Due to RF Radiation Signal (RF 방사 신호로 인한 특정 주파수 수신 잡음 현상의 원인분석 및 개선)

  • Kwon, Jung-Hyuk;Kim, Jong-Min;Lee, Wang-Sang
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.73-83
    • /
    • 2022
  • The purpose of this paper was to identify a method to improve received noise in a specific frequency band, caused by RF radiation signals during aircraft operation. The communication equipment of the aircraft is critical to the performance and safety of the flight mission, as it is responsible for the function of internal and external communications. Noise-free, clean communication quality, as well as transmission and receiving functions have to be implemented. Thus, the cause analysis of the reception noise in a specific frequency band, was analyzed through trouble shooting. The receiving noise due to the RF radiation signal emitted from the subsystem unit inside the aircraft, was improved by shielding with a CAP with electroless nickel plating applied. Additionally, the measurement and verification results of the improvement method are also described.

Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles (시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교)

  • Seo, Hyekyung;Jang, Hoyeong;Shim, Sua;Kim, Huiju;Han, Donhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.

A Research on the Promotion of AMI Supply by the Development of 1:N Mounted Remote Meter Reading Device (1:N HUB 기능을 가진 원격검침 단말기 개발에 따른 AMI 보급 추진 방안 연구)

  • Lee, Hyoung-Min;Kim, Min-Gi;Choi, Eun-Il;Yoon, Chan-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.1-6
    • /
    • 2021
  • In this study, we developed AMI terminals of 1 (reader): N (small transmitter). Currently, the government is focusing on the Gas AMI demonstration project to advance the outdated metering system of the urban gas industry, led by the government-sponsored ministries. The supply of gas AMI meters has the advantage of resolving uncertainties in privacy violations and measurement information and preparing for consumer safety through gas leakage detection. In the case of existing AMI meters, readers and transmitters were 1:1 methods, while this technology can be extended to multiple generations with a 1:N method, and a technology that can extend battery life by implementing a low-power design is applied. We hope that this research will contribute to the gas AMI supply project in the future.

Physicochemical and Antibacterial Effects of Curcuma aromatica Salis b. with or without Fermentation on varied calorie levels of HMR Bibimbap set (열량 수준별 간편가정식 비빔밥세트에 첨가된 일반 및 발효 강황의 이화학적 항산화적 효과)

  • Wu, Xiu Bao;Kim, Eun Kyung;Kim, Hae-Young
    • Journal of the FoodService Safety
    • /
    • v.2 no.1
    • /
    • pp.44-50
    • /
    • 2021
  • Physicochemical and antioxidant properties of the three different calorie types of HMR curry rice using fermented turmeric were analyzed in this study. The general tumeric added sample groups showed significantly higher carbohydrate content than the fermented turmeric sample group. In all sample groups, the ratio of protein, fat, and carbohydrate was found to be appropriate according to the nutritional composition ratio as one meal recommended by the Ministry of Health and Welfare. The brightness L value of the general turmeric-added sample group was measured to be significantly brighter than the fermented turmeric-added sample group. The fermented turmeric sample group showed a slightly lower pH value than the general sample group due to organic acids generated during fermentation. As a result of analyzing the radical scavenging activity of ABTS, LFTC, MFTC, and HFTC of the fermented turmeric group were 40.20, 40.46, and 36.16%, respectively, compared to those 32.41, 37.75, and 36.16% of LNTC, MNTC and FNTC of the general sample groups, respectively, consistently indicating that more free radicals were generated in the fermented sample group (p<0.01). Relatively unstable to heat and acid, DPPH scavenged radicals showed similar results to those of ABTS radical scavenging activity in terms of activity. Similar results were also shown in the measurement of total flavonoid and phenol content, which are known to have antioxidant antiviral and anticancer effects. Thus we could conclude that pilot products of the high quality varied calorie levels of HMR Bibimbap set with tumeric, which is helpful for antioxidant action have been developed to meet various customer needs.

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

Integration of 3D Laser Scanner and BIM Process for Visualization of Building Defective Condition (3D 레이저 스캐닝과 BIM 연동을 통한 건축물 노후 상태 정보 시각화 프로세스)

  • Choi, Moonyoung;Kim, Sangyong;Kim, Seungho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.2
    • /
    • pp.171-182
    • /
    • 2022
  • The regular assessment of a building is important to understand structural safety and latent risk in the early stages of building life cycle. However, methods of traditional assessment are subjective, atypical, labor-intensive, and time-consuming and as such the reliability of these results has been questioned. This study proposed a method to bring accurate results using a 3D laser scanner and integrate them in Building Information Modeling (BIM) to visualize defective condition. The specific process for this study was as follows: (1) semi-automated data acquisition using 3D laser scanner and python script, (2) scan-to-BIM process, (3) integrating and visualizing defective conditions data using dynamo. The method proposed in this study improved efficiency and productivity in a building assessment through omitting the additional process of measurement and documentation. The visualized 3D model allows building facility managers to make more effective decisions. Ultimately, this is expected to improve the efficiency of building maintenance works.

Rapid Self-Configuration and Optimization of Mobile Communication Network Base Station using Artificial Intelligent and SON Technology (인공지능과 자율운용 기술을 이용한 긴급형 이동통신 기지국 자율설정 및 최적화)

  • Kim, Jaejeong;Lee, Heejun;Ji, Seunghwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.9
    • /
    • pp.1357-1366
    • /
    • 2022
  • It is important to quickly and accurately build a disaster network or tactical mobile communication network adapting to the field. In configuring the traditional wireless communication systems, the parameters of the base station are set through cell planning. However, for cell planning, information on the environment must be established in advance. If parameters which are not appropriate for the field are used, because they are not reflected in cell planning, additional optimization must be carried out to solve problems and improve performance after network construction. In this paper, we present a rapid mobile communication network construction and optimization method using artificial intelligence and SON technologies in mobile communication base stations. After automatically setting the base station parameters using the CNN model that classifies the terrain with path loss prediction through the DNN model from the location of the base station and the measurement information, the path loss model enables continuous overage/capacity optimization.

Development of Thermostat for the Fluxgate Magnetometer in Icheon Geomagnetic Observatory and Stability Evaluation after Installation (이천 지자기 관측소 플럭스게이트 자력계 온도 조절 장치 개발 및 설치 후 안정성 자체 평가 )

  • Dooyoung, Choi;Seunguk, Lee;Joonsung, Kim;Dae-Young, Lee;Kyu-Cheol, Choi;Junghee, Cho
    • Journal of Space Technology and Applications
    • /
    • v.2 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This paper reports on the design and installation of a thermostat to keep the temperature of the fluxgate magnetometer constant and the data stability evaluation after installation. The thermostat was installed at the Icheon Geomagnetic Observatory operated by the Korean Space Weather Center of National Radio Research Agency. It was designed in consideration of stability of temperature control against safety incident, potential effects on magnetic field measurement, and the temperature control efficiency. After the temperature control device was installed, it was confirmed that the temperature was constantly maintained at the level of 20℃. Delta F and baseline values were used to evaluate geomagnetic data stability, and it was confirmed that delta F and baseline fluctuations were reduced after installation of the thermostat.