• Title/Summary/Keyword: Safety measurement

Search Result 2,493, Processing Time 0.037 seconds

Review of National Diagnostic Reference Levels for Interventional Procedures

  • Lee, Min Young;Kwon, Jae;Ryu, Gang Woo;Kim, Ki Hoon;Nam, Hyung Woo;Kim, Kwang Pyo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.75-88
    • /
    • 2019
  • Diagnostic reference level (DRL) is employed to optimize the radiation doses of patients. The objective of this study is to review the DRLs for interventional procedures in Korea and abroad. Literature review was performed to investigate radiation dose index and measurement methodology commonly used in DRL determination. Dose area product (DAP) and fluoroscopy time within each major procedure category were systematically abstracted and analyzed. A wide variation was found in the radiation dose. The DAP values and fluoroscopy times ranged 0.01-3,081 Gy·㎠ and 2-16,878 seconds for all the interventional procedures, 8.5-1,679 Gy·㎠ and 32-5,775 seconds for the transcatheter arterial chemoembolization (TACE), and 0.1-686 Gy·㎠ and 16-6,636 seconds for the transfemoral cerebral angiography (TFCA), respectively. The DRL values of the DAP and fluoroscopy time were 238 Gy·㎠ and 1,224 seconds for the TACE and 189 Gy·㎠ and 686 seconds for the TFCA, respectively. Generally, the DRLs of Korea were lower than those of other developed countries, except for the percutaneous transluminal angioplasty with stent in arteries of the lower extremity (LE PTA and stent), aneurysm coil embolization, and Hickman insertion procedures. The wide variation in the radiation doses of the different procedures suggests that more attention must be paid to reduce unnecessary radiation exposure from medical imaging. Furthermore, periodic nationwide survey of medical radiation exposures is necessary to optimize the patient dose for radiation protection, which will ultimately contribute to patient dose reduction and radiological safety.

Improvement of Inflow Estimation Data by Precise Measurement of Water Level in Reservoir (저수지 수위 정밀 측정에 의한 댐 유입량 자료 개선)

  • Park, Ji-Chang;Kim, Nam;Ryoo, Kyong-Sik
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.309-314
    • /
    • 2009
  • A accurate reservoir inflow is very important as providing information for decision making about the water balance and the flood control, as well as for dam safety. The methods to calculate the inflow were divided by the directed method to measure streamflow from upstream reservoirs and the indirected method to estimate using the correlation of reservoir water level and release. Currently, the inflow of multi-purpose dam is being calculated by the indirect method and the reservoir water level to calculate the storage capacity is being used by centimeters(cm) units. Corresponding to the storage volume of 1cm according to scale and water level of multi-purpose dam comes up to from several 10 thousand tons to several million tons. If it converts to inflow during 1 hour, and it comes to several hundred $m^3/sec$(CMS). Therefore, the inflow calculated on the hourly is largely deviated along the water level changes and is occurred minus value as the case. In this research, the water level gage has been developed so that it can measure a accurate water level for the improvement for the error and derivation of inflow, even though there might be various hydrology and meteorologic considerations to analyse the water balance of reservoir. Also, it is confirmed that the error and the standard derivation of data observed by the new gage is decreased by 89,6% and 1/3 & 87% and 2/3 compared to that observed by the existing gage of Daecheong and Juam multi-purpose dam.

Study on Wear Properties of GCV Materials with DLC Coating (GCV소재의 DLC 코팅 마모특성에 관한 연구)

  • Lee, Soo-Chul;Kim, Nam-Seok;Nam, Ki-Woo;Ahn, Seok-Hwan;Kim, Hyun-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.71-75
    • /
    • 2010
  • Although Graphite Compacted Vermicular (GCV) was first observed in 1948, the narrow range for stable foundry production precluded the high volume application of GCV to complex components such as cylinder blocks and heads until advanced process control technologies became available. This, in turn, had to await the advent of modern measurement electronics and computer processors. Following the development of foundry techniques and manufacturing solutions, primarily initiated in Europe during the 1990s, the first series production of GCV cylinder blocks began during 1999. Today, more than 40,000 GCV cylinder blocks are produced each month for OEMs, including Audi, DAF, Ford, Hundai, MAN, Mercedes, PSA, Volkswagen, and Volvo. Given that new engine programs are typically intended to support three to four vehicle generations, the chosen engine materials must satisfy current design criteria and also provide the potential for future performance upgrades without changing the overall block architecture. With at least a 75% increase in the ultimate tensile strength, a 40% increase in the elastic modulus, and approximately double the fatigue strength of either iron or aluminum, GCV is ideally suited to meet current and future of engine design and performance requirements.

Damage Detection of Building Structures Using Ambient Vibration Measuresent (자연진동을 이용한 건물의 건전도 평가)

  • Kim, Sang Yun;Kwon, Dae Hong;Yoo, Suk Hyeong;Noh, Sam Young;Shin, Sung Woo
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.147-152
    • /
    • 2007
  • Numerous non-destructive tests(NDT) to assess the safety of real structures have been developed. System identification(SI) techniques using dynamic responses and behaviors of structural systems become an outstanding issue of researchers. However the conventional SI techniques are identified to be non-practical to the complex and tall buildings, due to limitation of the availability of an accurate data that is magnitude or location of external loads. In most SI approaches, the information on input loading and output responses must be known. In many cases, measuring the input information may take most of the resources, and it is very difficult to accurately measure the input information during actual vibrations of practical importance, e.g., earthquakes, winds, micro seismic tremors, and mechanical vibration. However, the desirability and application potential of SI to real structures could be highly improved if an algorithm is available that can estimate structural parameters based on the response data alone without the input information. Thus a technique to estimate structural properties of building without input measurement data and using limited response is essential in structural health monitoring. In this study, shaking table tests on three-story plane frame steel structures were performed. Out-put only model analysis on the measured data was performed, and the dynamic properties were inverse analyzed using least square method in time domain. In results damage detection was performed in each member level, which was performed at story level in conventional SI techniques of frequency domain.

Disposable Strip-type Sensors for Detection of Free Chlorine (유리염소 측정을 위한 일회용 스트립 센서)

  • Kim, Seung Ki;Kang, Tae Young;Cha, Geun Sig;Nam, Hakhyun;Shin, Jae Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.4
    • /
    • pp.242-248
    • /
    • 2012
  • The measurement of residual chlorine as a disinfectant is very important to ensure the safety against the pathogenic microbes and to suppress injection. The portable free chlorine sensor was fabricated with a disposable strip format by a screen printing method. The strip sensors prepared with a carbon-Ag/AgCl(cathode-anode) combination exhibited less interfering responses towards combined chlorine species(especially $NHCl_2$) and oxygen than the sensors prepared with other metals(i.e., gold and platinum). Free chlorine was determined chronoamperometrically with carbon-based electrodes at an applied potential of -0.3 V(vs. Ag/AgCl). A channel was built on the strip-type electrode for easy sampling, and the resulting strip sensors were employed to determine the concentrations of residual free chlorine.

Measurement system developed for the safety analysis of moored Floating matters (계류된 부유체의 안전성 평가를 위한 계측시스템 개발)

  • Park, Kyung-Chul;Yang, Hye-Jung;Seong, Yu-Chang
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.165-166
    • /
    • 2013
  • When Coming alongside the shallow water or narrow pier, they apply sea area with small mooring facilities and Floating matter because of the diversity of ships and limitation and effective in cutting expenses. However, when ships, applying Small mooring facilities and Floating matter, come alongside, there can be some impulse by waves between the Floating things and ships which possibly leads to mass disaster. Therefore, there should be forecasts and analysis of the movement caused by waves. On this Study, it introduces the composition and principles of the developed system provides the base of the movement traits through measuring 3-D exercise data and acceleration of the Mooring and Floating matters.

  • PDF

Radiation Doses and Quality Assurance in Cone Beam CT(CBCT) (임상가를 위한 특집 4 - CBCT 검사법의 정도관리 및 선량)

  • Choi, Yong-Suk;Kim, Gyu-Tae;Hwang, Eui-Hwan
    • The Journal of the Korean dental association
    • /
    • v.52 no.3
    • /
    • pp.153-163
    • /
    • 2014
  • 3-dimensional information for anatomic stucture plays a role as integral part in clinical aspect of dental practice. CBCT(cone beam computed tomography) has been accepted as useful diagnostic tool offering Volume data and images for evaluating teeth and jaws in lower radiation dose than conventional CT. CBCT equipment is essential for the quality assurance of it to ensure continued satisfactory performance and result of adequate images. Dental practitioner and oral and maxillofacial radiologist should have a responsibility and critical thinking to deliver this technology to patients in a responsible way, so that diaganostic value is maximised and radiation doses kept as low as resonably achievable. CBCT imaging modality should be used only after a review of the patient's health and imaging history and the completion of a thorough clinical examination. Clinical guidelines are systematically developed statements to assist practitioner and patient decisions about appropriate health care for specific clinical circumstances Dental practitioners should prescribe CBCT imaging only when they expect that the diagnostic yield will benefit patient care, enhance patient safety or improve clinical outcomes significantly. Knowledge of patient dose is essential for clinicians who are making the decision regarding the justification of the exposure. There are some limitation in the measurement of patient dose in CBCT for the approval and adaptation of conventinal methodolgy in CT. It is also important to ensure that doses are optimised and in line with any national and international guidelines. The higher radiation doses of CBCT compared with conventional radiography, mean that high standards must be maintained. The Quality Assurance(QA) programme should entail surveys and checks that are performed according to a regular timetable. QA programme should be maintained by staff to ensure adherence to the programme and to raise its importance among staff.

Evaluation on Corrosion Behaviour and Adhensivity of Oxide Coated Materials (산화물 피복강재의 부식거동 및 밀착성 평가)

  • Lee Jong-Rark
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.34-41
    • /
    • 1998
  • To oxide film, $A1_2O_3,\;Ta_2O_5$ and $ZrO_2$, coated on stainless steel (SUS410, SUS304) and pure Fe using RF magnetron sputtering method, the corrosion resistance on oxide coatings was studied using electrochemical measurement. Also, the adherence between film and substarte was studied. The adherence index ( $\chi$ ) was determined by the measure of micro hardness test. In this paper, we know that oxide film coated on SUS304 have better corrosion resistance than that coated on SUS410. In oxide film, the difference of corrosion resistance due to crystal structure have not been showed. In evaluating defect area rate of ceramic coated materials, CPCD method can be used effectively. In the micro-hardness test, with $1{\mu}m$ thickness film, it has only one the value of $\chi$. Above $2{\mu}m$ thickness film, however, get another value of $\chi$ as the cracks in film. The oxide film adhere well on the mild materials such as pure steel than high intensity materials like stainless.

  • PDF

The development of pH reading system based on vision system (영상 기반 pH 산도 측정 시스템 개발)

  • Moon, Ha-Jung;Lee, Dong-Hoon
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.398-406
    • /
    • 2013
  • Nuclear medicine imaging devices such as PET diagnose disease after injecting radiopharmaceuticals in human body for diagnosis. Radiopharmaceuticals should maintain the proper pH for human body safety. In general, pH paper is used to measure the pH of the radiopharmaceutical. pH of the sample compared with the standard color chart is used for measurement. However, the pH reading difference according to the experience of a rater can be generated. Also, a pH meter for measuring pH has a high sensitivity and contamination of the sensor must be avoided. In this paper, we developed the new hardware device for pH reading method and software was developed with vision algorithm to measure pH easily and simply.

A Study on Optimal Layout of Control Buttons on Center Fascia Considering Human Performance under Emergency Situations (돌발 상황 하의 사용자 반응을 고려한 자동차 중앙 계기판 버튼의 최적 배치 방안 연구)

  • Choi, Jun-Young;Kim, Young-Su;Bahn, Sang-Woo;Yun, Myung-Hwan;Lee, Myun-Woo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.3
    • /
    • pp.365-373
    • /
    • 2010
  • Many studies on safety issues of human-machine interaction are being conducted, especially taking emergency situations into consideration. In light of this view, the importance of objective and reliable measurement of users' reactions under emergency situations is becoming more important than ever in reflecting such issues in the design of everyday things. However, despite the need to consider the human-machine interactions and human performances at the design stage, there were few studies which considered human performances and behaviors under emergency situations. This study is about an evaluation method and design guide to include such human performances under emergency situations during human-machine interactions. This is achieved through an experiment where operators are instructed to press the emergency button at an experimentally designed location under a random emergency situation. By analyzing the results in a human factors perspective, the response time and the accuracy of the operators' behaviors are explained. Analysis revealed that in designing the center fascia for automobiles, there is a tradeoff between response time and accuracy, and the optimal size of buttons differ in each part of the center fascia. This method is expected to be applicable to industrial situations to derive optimal position for emergency buttons.