• Title/Summary/Keyword: Safety measurement

Search Result 2,482, Processing Time 0.034 seconds

Software Reliability of Safety Critical FPGA-based System using System Engineering Approach

  • Pradana, Satrio;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.14 no.2
    • /
    • pp.49-57
    • /
    • 2018
  • The main objective of this paper is come up with methodology approach for FPGA-based system in verification and validation lifecycle regarding software reliability using system engineering approach. The steps of both reverse engineering and re-engineering are carried out to implement an FPGA-based of safety critical system in Nuclear Power Plant. The reverse engineering methodology is applied to elicit the requirements of the system as well as gain understanding of the current life cycle and V&V activities of FPGA based-system. The re-engineering method is carried out to get a new methodology approach of software reliability, particularly Software Reliability Growth Model. For measure the software reliability of a given FPGA-based system, the following steps are executed as; requirements definition and measurement, evaluation of candidate reliability model, and the validation of the selected system. As conclusion, a new methodology approach for software reliability measurement using software reliability growth model is developed.

A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System (TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구)

  • Yi, Geon-Ho;Jung, Jin-Soo;Moon, Hyun-Wook;Kim, Sun-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

Conceptualizing Safety Systems Human Performance improvement using Augmented Reality

  • Murungi, Mwongeera;Jung, JaeCheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.2
    • /
    • pp.81-90
    • /
    • 2016
  • The system performance of Engineered Safety Features is of utmost importance in a nuclear power plant. The human performance is identified as most critical to assurance of the optimal operability of safety systems during an emergency. The aim of this study is to determine how the performance of safety system could be evaluated using Augmented Reality technology. The paper presents a description of how a systems engineered approach could be used to develop the necessary operating conditions needed to conduct this measurement. Augmented Virtual Reality (AVR) interface technology is achieving ease of availability and widespread use in many applications today as illustrated by the launch of several AR and VR devices aimed at media consumption. As such, environments that incorporate such AVR hardware have become invaluable tools in designing human interface systems because of the high fidelity and intuitive response to natural human interaction that can be achieved [2]. The outcome of the measurement undertaken is to determine whether 1.) Operator(s) performance can be enhanced by introducing an improved cognitive method of monitoring plant information during an Emergency Operating Procedures (EOP) and 2.) In correlation, inform the performance of the diverse safety systems on the basis of human factors.

Development of Disaster and Safety Practice Measurement Tool for Elderly People in Rural Area (농촌 지역사회 노인의 재난·안전 실천행위 측정도구 개발)

  • Seo, Ji-Hye;Hong, Ju-Young;Kim, Sang Sook;Kang, In-Won;Jung, Eun-Young
    • Journal of Korean Academy of Rural Health Nursing
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Purpose: This purpose of this study was to develop a disaster and safety practice measurement tool for elderly people in rural areas. Methods: The tool for this study was developed and validated according to DeVellis' scale development process. The construct validity of the instrument was analyzed by major analysis of Varimax rotation, and the internal inertia was verified by Cronbach's ⍺. Results: The final scale was a 4-point scale, consisting of 23 items in 7 domains. The total explanation was 54.1% and the Cronbach's ⍺ was .80. Conclusion: The results of this study should be useful to assess elders' perception of the importance of safety management for elders.

A Study on Prevention of Workers' Noise-Induced Deafness at Aluminum Form Dismantle in Construction Industries (건설업 알루미늄폼 해체작업 시 근로자에 대한 소음성난청 예방에 관한 연구)

  • Park, Jae Kuk;Oh, Tea Keun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.95-102
    • /
    • 2019
  • The purpose of this study is to investigate the correlation between aluminum form work and noise-induced deafness by conducting special health examination on construction aluminum worker and noise measurement at the workplace. All the 11 aluminum form workers were diagnosed with noise-induced deafness after holding a special health examination. The workers have not had any previous history of noise-induced deafness which indicates that aluminum form work is related to noise-induced deafness disease. The impact noise of 120 dB(A)~125 dB(A), which exceeds the regulations of industrial safety and health act, was found during the dismantling rather than installation when noise measurement was made at the aluminum workplace. The aluminum form workers could permanently lose the hearing sense if they are exposed to this impact noise. This study is to suggest the method to prevent noise-induced deafness for aluminum form workers by firstly giving out hearing protection equipment at the construction site and secondly installing rubber mat, soundproof panel as well as changing the noise-lowering technique.

Post-earthquake fast building safety assessment using smartphone-based interstory drifts measurement

  • Hsu, Ting Y.;Liu, Cheng Y.;Hsieh, Yo M.;Weng, Chi T.
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.287-299
    • /
    • 2022
  • Rather than using smartphones as seismometers with designated locations and orientations, this study proposes to employ crowds' smartphones in buildings to perform fast safety assessment of buildings. The principal advantage of using crowds' smartphones is the potential to monitor the safety of millions of buildings without hardware costs, installation labor, and long-term maintenance. This study's goal is to measure the maximum interstory drift ratios during earthquake excitation using crowds' smartphones. Beacons inside the building are required to provide the location and relevant building information for the smartphones via Bluetooth. Wi-Fi Direct is employed between nearby smartphones to conduct peer-to-peer time synchronization and exchange the acceleration data measured. An algorithm to align the orientation between nearby smartphones is proposed, and the performance of the orientation alignment, interstory drift measurement, and damage level estimation are studied numerically. Finally, the proposed approach's performance is verified using large-scale shaking table tests of a scaled steel building. The results presented in this study illustrate the potential to use crowds' smartphones with the proposed approach to record building motions during earthquakes and use those data to estimate buildings' safety based on the interstory drift ratios measured.

Optimization of Acquisition Time of Beta-Gamma Coincidence Counting System for Radioxenon Measurement (방사성제논 탐지를 위한 베타-감마 동시 계측시스템의 측정시간 최적화)

  • Byun, Jong-In;Park, Hong-Mo;Choi, Hee-Yeoul;Song, Myeong-Han;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.181-186
    • /
    • 2015
  • Measurement of xenon radioisotopes from nuclear fission is a key element for monitoring underground nuclear weapon tests. $^{131m}Xe$, $^{133}Xe$, $^{133}mXe$ and $^{135}Xe$ in the air can be detected via low background systems such as a beta-gamma coincidence counting system. Radioxenon monitoring is performed through air sampling, xenon extraction, measurement and spectrum analysis. The minimum detectable concentration of $^{135}Xe$ can be significantly variable depending on the sampling time, extraction time and data acquisition time due to its short half-life. In order to optimize the acquisition time with respect to certain experimental parameters such as sampling and xenon extraction, theoretical approach and experiment using SAUNA system were performed to determine the time to minimize the minimum detectable concentration, which the results were discussed.

Real-Time Measurement of the Liquid Amount in Cryo-Electron Microscopy Grids Using Laser Diffraction of Regular 2-D Holes of the Grids

  • Ahn, Jinsook;Lee, Dukwon;Jo, Inseong;Jeong, Hyeongseop;Hyun, Jae-Kyung;Woo, Jae-Sung;Choi, Sang-Ho;Ha, Nam-Chul
    • Molecules and Cells
    • /
    • v.43 no.3
    • /
    • pp.298-303
    • /
    • 2020
  • Cryo-electron microscopy (cryo-EM) is now the first choice to determine the high-resolution structures of huge protein complexes. Grids with two-dimensional arrays of holes covered with a carbon film are typically used in cryo-EM. Although semi-automatic plungers are available, notable trial-and-error is still required to obtain a suitable grid specimen. Herein, we introduce a new method to obtain thin ice specimens using real-time measurement of the liquid amounts in cryo-EM grids. The grids for cryo-EM strongly diffracted laser light, and the diffraction intensity of each spot was measurable in real-time. The measured diffraction patterns represented the states of the liquid in the holes due to the curvature of the liquid around them. Using the diffraction patterns, the optimal time point for freezing the grids for cryo-EM was obtained in real-time. This development will help researchers rapidly determine high-resolution protein structures using the limited resource of cryo-EM instrument access.

Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc (직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발)

  • Kim, Doo-Hyun;Park, Jong-Young;Kim, Sung-Chul;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.

A Study on Measurement of Length and Slope of Temporary Structure using UAV (무인항공기를 활용한 가설구조물의 길이와 기울기 측정에 관한 연구)

  • Min-Guk, Kang;Seung-Hyeon, Shin;JongKeun, Park;Jeong-Hun, Won
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.89-95
    • /
    • 2022
  • A method for measuring the length and slope of a temporary structure using an unmanned aerial vehicle (UAV) and 3D modeling method is proposed. The actual length and slope of the vertical member of the specimen were measured and compared with the measured values obtained by the proposed method for the specimens with and without the vertical protection net installed. Based on the result of measuring the length of the temporary structure specimen using the UAV and 3D modeling method, the measured value showed an error of 0.87% when compared to the actual length in the specimen without the vertical protection net installed. In addition, the error of the slope was 0.63°. It was thought that the proposed method could be usable for the purpose of finding parts in wrong installation state on the temporary structure and informing the manager in charge. However, in the case of the specimen with the vertical protection net, the measurement showed a 1.46% error in length and 2.77° difference in slope. Therefore, if a vertical protection net is to be installed in a temporary structure, the measurement accuracy should be improved by utilizing an image processing method, etc.